Empire Comfort Systems RB), GWT-50-2 installation instructions Introduction, Specifications

Page 5

INTRODUCTION

Introduction

Vented wall furnace is shipped ready to install in a 2" x 4" stud wall, with studs 16" (406mm) center to center. Always consult your local Building Department regarding regulations, codes or ordinances which apply to the installation of a vented wall furnace.

Instructions to Installer

1.Installer must leave instruction manual with owner after installation.

2.Installer must have owner Þll out and mail warranty card supplied with furnace.

3.Installer should show owner how to start and operate furnace and thermostat.

Warning:

Any change to this furnace or its control can be dangerous. This is a heating appliance and any panel, door or guard removed forservicing an appliance must be replaced prior to operating the appliance.

General Information

This series is design certiÞed in accordance withAmerican National Standard / CSA Standard Z21.86 and CSA 2.32 by the Canadian Standards Association, as a Vented Wall Furnace and must be installed according to these instructions.

Any alteration of the original design, installed other than as shown in these instructions or use with a type of gas not shown on the rating plate is the responsibility of the person and company making the change.

Important

All correspondence should refer to complete Model No., Serial No. and type of gas.

Notice: During initial Þring of this furnace, its paint will bake out and smoke will occur. To prevent triggering of smoke alarms, ventilate the room in which the furnace is installed.

Installation in Residential Garages

Gas utilization equipment in residential garages shall be installed so that all burners and burner ignition devices are located not less than 18" (457mm) above the ßoor.

Such equipment shall be located, or protected, so it is not subject to physical damage by a moving vehicle.

QualiÞed Installing Agency

Installationandreplacementofgas piping,gasutilizationequipment or accessories and repair and servicing of equipment shall be performed only by a qualiÞed agency. The term "qualiÞed agency" means any individual, Þrm, corporation or company which either in person or through a representative is engaged in and is responsible for (a) the installation or replacement of gas piping or (b) the connection, installation, repair or servicing of equipment, who is experienced in such work, familiar with all precautions required and has complied with all the requirements of the authority having jurisdiction.

State of Massachusetts: The installation must be made by a licensed plumber or gas Þtter in the Commonwealth of Massachusetts.

The installation must conform to local codes or, in the absence of local codes, with the National Fuel Gas Code ANSI Z223.1/NFPA 54* Natural Gas and Propane Installation Code, CSA B149.1.

*Available from the American National Standards Institute, Inc., 11 West 42nd St., New York, N.Y. 10036.

High Altitudes

For altitudes/elevations above 2,000 feet (610m), input ratings should be reduced at the rate of 4 percent for each 1,000 (305m) feet above sea level. Canadian HighAltitudes for locations having an elevation above mean sea level between 2,000 feet (610m) and 4,500 feet (1370m), the manifold pressure is to be decreased from 3.5" w.c. (.871kPa) to 3.0" w.c. (.747kPa) for Natural Gas and from 10.0" w.c. (2.49kPa) to 8.0" w.c. (1.992kPa) for Propane Gas.

 

SPECIFICATIONS

 

 

 

 

 

Model

 

GWT-50

 

Input BTU/HR (KW/H)

 

50,000 (14.7)

 

Height

 

66 1/8" (168cm)

 

Width

 

16" (406mm)

 

Depth (Out of wall)

 

6" (152mm)

 

Gas Inlet Pipe

 

1/2"

 

Vent Pipe Type B Oval

 

4" (102mm)

 

Accessory

 

 

 

Blower Package

 

GWTB-2

 

 

 

 

 

GWT-50 (SG, RB) is a DUAL WALL Furnace. Warmed air is discharged into two rooms which share a common wall.

12426-4-0104

Page 5

Image 5
Contents Installation Instructions Table of Contents This is a Heating Appliance Important Safety InformationLP-GAS Warning Odor Safety Information for Users of LP-GASIntroduction SpecificationsInsulated Vent Enclosure Recommended Vent ConfigurationOval all parts purchase locally Pressure Testing of the Gas Supply System Installing a New Main Gas CockGAS Supply Checking Manifold PressureVentilation and Combustion AIR ClearancesLocation ALL Models ROUGH-IN InstructionsPlastering Figure Installing Furnace FigureFinishing Instructions Outer Casing Figure Finishing InstructionsSystem Check Figure Thermostat Location SG ModelsTurn clockwise OFF Lighting InstructionsProper Pilot Flame Vent Safety Shutoff SystemProper Main Burner Flame Main Gas Valve Does Not Open When Thermostat Is Turned On TroubleshootingPilot Does Not Light If Pilot Does Not Light By Any MeansEmpire Comfort Systems, Inc. Nine Eighteen Freeburg Ave Parts ListHOW to Order Repair Parts Parts View Models Remote Bulb Control Installation InstructionsGWT-25 SG, RB, GWT-35 SG, RB, GWT-50 SG, RB Optional Blower Installation InstructionsGWTB-2 Wiring Diagram Service Notes

RB), GWT-50-2 specifications

Empire Comfort Systems GWT-50-2, RB is a versatile and efficient gas wall heater that showcases innovative technology and thoughtful design, making it an ideal heating solution for both residential and commercial spaces. Designed for optimal performance, the GWT-50-2, RB delivers reliable warmth even in the coldest of climates, ensuring comfort without the hassle of traditional heating methods.

One of the defining characteristics of the GWT-50-2, RB is its 50,000 BTU output, providing substantial heating capability. This unit can effectively heat spaces up to 1,000 square feet, making it suitable for larger rooms or open-plan areas. Its compact design and wall-mounted installation save valuable floor space while still offering robust heating power.

Featuring a direct vent design, the heater draws fresh air from outside for combustion and expels exhaust gases, ensuring safe and efficient operation. This design not only enhances efficiency but also protects indoor air quality by minimizing the risk of harmful fumes infiltrating living areas.

The GWT-50-2, RB comes equipped with a robust electronic ignition system, which allows for easy start-up without the need for a standing pilot light. This feature also contributes to energy savings, as the heater can operate only when needed. The advanced thermostat controls allow users to set their preferred temperature, providing tailored comfort and reducing energy consumption.

Another notable feature is the energy-efficient design of the heater, which includes a fan-blower system that circulates warm air throughout the room. This enhances thermal distribution, ensuring that heat reaches every corner of the space without any cold spots.

Additionally, the sleek and stylish appearance of the GWT-50-2, RB allows it to blend harmoniously with various interior decors. Available in multiple finishes, it can be a complementary addition to any home or office environment.

In summary, the Empire Comfort Systems GWT-50-2, RB stands out as a powerful yet efficient heating solution. Its high BTU output, energy-efficient technology, user-friendly controls, and aesthetically pleasing design make it an excellent choice for anyone seeking reliable comfort in their living or working spaces. With Empire's commitment to quality and innovation, users can trust that this gas wall heater will provide comfort and warmth for years to come.