Empire Comfort Systems RB), GWT-50-2 Parts List, HOW to Order Repair Parts

Page 15

PARTS LIST

ATTENTION: When ordering parts, it is very important that part number and description of part coincide.

Index

Part

 

Index

Part

 

 

No.

Number

Description

No.

Number

Description

 

 

 

 

 

 

 

1

WFA-115

HEADER GASKET

16

GWT-095

EXCHANGER ASSEMBLY -

2

GWT-175

HEADER ASSEMBLY

 

 

REAR

 

 

 

(INCLUDES NO. 1, GASKET)

17

GWT-094

EXCHANGER ASSEMBLY -

 

 

(USA)

 

 

FRONT

 

2

15756

HEADER ASSEMBLY

18

R-3036

PILOT - NAT

 

 

 

(INCLUDES NO. 1, GASKET)

18

R-3037

PILOT - LPG

 

 

 

(CANADA)

19

R-1054

THERMOPILE

3

GWT-184

INNER CASING ASSEMBLY

20

GWT-096

BURNER BRACKET ASSEMBLY

4

GWT-151

DIVERTER ASSEMBLY

21

R-5245

GAS VALVE - NAT

 

 

(2 REQUIRED)

 

 

21

R-5246

GAS VALVE - LPG

5

GWT-020

FRONT SHIELD (2 REQUIRED)

22

R-3031

BURNER

(6 REQUIRED)

6

GWT-077

HEAT SHIELD (2 REQUIRED)

23

P-88-55

BURNER ORIFICE - NAT

7

GWT-177

OUTER CASING ASSEMBLY

 

 

(6 REQUIRED)

 

 

(2 REQUIRED)

 

 

 

 

23

P-88-65

BURNER ORIFICE - LPG

8

GWT-186

CASING BRACKET

 

 

(6 REQUIRED)

 

 

(4 REQUIRED)

 

 

 

 

24

GWT-014

AIR SHUTTER FRONT - LPG

9

GWT-087

CASING DOOR ASSEMBLY

 

 

(2 REQUIRED)

 

 

(2 REQUIRED) (USA)

 

 

 

 

25

GWT-015

AIR SHUTTER REAR - LPG

9

15739

CASING DOOR ASSEMBLY

 

 

(2 REQUIRED)

 

 

(2 REQUIRED) (CANADA)

 

 

 

 

26

GWT-054

AIR SHUTTER BOTTOM - LPG

10

R-885

NYLON WASHER

 

 

(2 REQUIRED)

 

 

(4 REQUIRED)

 

 

 

 

NOT SHOWN

GWT-099

PILOT TUBING

11

CI-253

MAGNET (4 REQUIRED)

NOT SHOWN

R-3178

PILOT ORIFICE (HONEYWELL

12

DV-064

COVER PLATE (2 REQUIRED)

 

 

K14 .014 LPG ONLY)

13

GWT-008

BURNER COMPARTMENT

NOT SHOWN

R-3179

PILOT ORIFICE (HONEYWELL

 

 

FRONT (2 REQUIRED)

 

 

A26 .026 NAT ONLY)

14

R-3046

VENT SAFETY SWITCH

NOT SHOWN

R-734

MATCH HOLDER

15

R-3038-A

ECO LEAD ASSEMBLY

NOT SHOWN

GWT-190

HARDWARE PACKAGE

 

 

 

 

 

(2 REQUIRED)

 

 

 

 

 

 

 

USE ONLY MANUFACTURER'S REPLACEMENT PARTS. USE OF ANY OTHER PARTS COULD CAUSE INJURY OR DEATH.

HOW TO ORDER REPAIR PARTS

Parts can be ordered only through your service person or dealer. For best results, the service person or dealer should order parts through the distributor. Parts can be shipped directly to the service person/dealer.

All parts listed in the Parts List have a Part Number. When ordering parts, Þrst obtain the Model Number from the name plate on your equipment. Then determine the Part Number (not the Index Number) and the Description of each part from the following appropriate illustration and list. Be sure to give all this information . . .

Furnace Model Number

 

 

 

 

Part Description

 

 

 

 

 

 

 

Furnace Serial Number

 

 

 

 

 

Part Number

 

 

 

 

 

 

 

 

 

 

Type of Gas (Propane or Natural)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Do not order bolts, screws, washers or nuts. They are standard hardware items and can be purchased at any local hardware store.

Shipments contingent upon strikes, Þres and all causes beyond our control.

Empire Comfort Systems, Inc. Nine Eighteen Freeburg Ave.

Belleville, Illinois 62222-0529

12426-4-0104

Page 15

Image 15
Contents Installation Instructions Table of Contents This is a Heating Appliance Important Safety InformationLP-GAS Warning Odor Safety Information for Users of LP-GASIntroduction SpecificationsRecommended Vent Configuration Oval all parts purchase locallyInsulated Vent Enclosure Checking Manifold Pressure Installing a New Main Gas CockPressure Testing of the Gas Supply System GAS SupplyROUGH-IN Instructions ClearancesVentilation and Combustion AIR Location ALL ModelsInstalling Furnace Figure Finishing InstructionsPlastering Figure Outer Casing Figure Finishing InstructionsSystem Check Figure Thermostat Location SG ModelsTurn clockwise OFF Lighting InstructionsVent Safety Shutoff System Proper Main Burner FlameProper Pilot Flame If Pilot Does Not Light By Any Means TroubleshootingMain Gas Valve Does Not Open When Thermostat Is Turned On Pilot Does Not LightParts List HOW to Order Repair PartsEmpire Comfort Systems, Inc. Nine Eighteen Freeburg Ave Parts View Models Remote Bulb Control Installation InstructionsGWT-25 SG, RB, GWT-35 SG, RB, GWT-50 SG, RB Optional Blower Installation InstructionsGWTB-2 Wiring Diagram Service Notes

RB), GWT-50-2 specifications

Empire Comfort Systems GWT-50-2, RB is a versatile and efficient gas wall heater that showcases innovative technology and thoughtful design, making it an ideal heating solution for both residential and commercial spaces. Designed for optimal performance, the GWT-50-2, RB delivers reliable warmth even in the coldest of climates, ensuring comfort without the hassle of traditional heating methods.

One of the defining characteristics of the GWT-50-2, RB is its 50,000 BTU output, providing substantial heating capability. This unit can effectively heat spaces up to 1,000 square feet, making it suitable for larger rooms or open-plan areas. Its compact design and wall-mounted installation save valuable floor space while still offering robust heating power.

Featuring a direct vent design, the heater draws fresh air from outside for combustion and expels exhaust gases, ensuring safe and efficient operation. This design not only enhances efficiency but also protects indoor air quality by minimizing the risk of harmful fumes infiltrating living areas.

The GWT-50-2, RB comes equipped with a robust electronic ignition system, which allows for easy start-up without the need for a standing pilot light. This feature also contributes to energy savings, as the heater can operate only when needed. The advanced thermostat controls allow users to set their preferred temperature, providing tailored comfort and reducing energy consumption.

Another notable feature is the energy-efficient design of the heater, which includes a fan-blower system that circulates warm air throughout the room. This enhances thermal distribution, ensuring that heat reaches every corner of the space without any cold spots.

Additionally, the sleek and stylish appearance of the GWT-50-2, RB allows it to blend harmoniously with various interior decors. Available in multiple finishes, it can be a complementary addition to any home or office environment.

In summary, the Empire Comfort Systems GWT-50-2, RB stands out as a powerful yet efficient heating solution. Its high BTU output, energy-efficient technology, user-friendly controls, and aesthetically pleasing design make it an excellent choice for anyone seeking reliable comfort in their living or working spaces. With Empire's commitment to quality and innovation, users can trust that this gas wall heater will provide comfort and warmth for years to come.