Empire Comfort Systems DV-35-2SG Thermostat Location, System Check Figure

Page 10

Warning: When vinyl siding vent kit, DV-822 or 2" x 4" (51mm x 102mm) framing is added to an existing installation (furnace is installed) do not attempt to add sections of pipe to the flue outlet tube or air inlet tube. An air tight seal is required for both tubes. Refer to Parts List, page 14 to order tubes.

Figure 5

Figure 5a

THERMOSTAT LOCATION

Millivolt wall thermostats are specially designed for use on self- generating systems. They should never be used on line or low voltage A.C. circuits.

Interior Wall — The thermostat should be installed on an inside wall away from the furnace but in the same room.

It is important to use wire of a gauge proper for the length of the wire:

RECOMMENDED WIRE GAUGES

Maximum Length

Wire Gauge

1' to 10'

18

10' to 25'

16

25' to 35'

14

Proper operation depends on a good pilot flame. The flame must cover the top of the thermopile. Cleaning of the pilot orifice and burner may be required due to spiders.

System Check (Figure 6)

Amillivolt meter is required to check the system. Millivolt readings should be:

Across the thermopile terminals, 400-450 millivolts with thermostat OFF.

Across the thermopile terminals, 150-250 millivolts with thermostat ON.

Across the thermostat wires at the valve, less than 30 millivolts with thermostat ON.

Across the thermostat wires at the thermostat, less than 5 millivolts with thermostat ON. (Strong winds, dirty pilot and low pressure will reduce readings.)

Piezo Pilot Ignitor Instructions

Depressing the red button completely causes a spark to occur at the pilot. This is a substitute for a match which requires opening the pilot hole cover.

To light the pilot, it is important that the electrode be 1/8" (3mm) from the thermopile. The spark must occur at the point the burner flame hits the thermopile. The end of the electrode will be red hot with the pilot on.

On a new installation with air in the gas line, it is suggested that a match be used. The match will light the pilot faster than the piezo under this condition.

Figure 6

Page 10

12434-9-0107

Image 10
Contents Installation Instructions Table of Contents Important Safety Information This is a Heating ApplianceSafety Informtaion for Users of LP-GAS Learn to recognize the odor of LP-gas. Your local LP-GasRequirements for Massachusetts Clear of ALL ObstructionsSpecifications IntroductionGAS Supply Recommended Gas Pipe DiameterClearances Installation InstructionsInstalling Wall Mounting Bracket Location of FurnaceAttaching Furnace To Wall Mounting Bracket Installing Vent AssemblyReassembly And Resealing Vent-Air Intake System Cutting Vent TubesSystem Check Figure Thermostat LocationPiezo Pilot Ignitor Instructions For Your Safety Read Before Lighting Lighting InstructionsMain Burner Flame Characteristics Pilot Flame CharacteristicsPrimary Air Adjustment Figure Maintenance TroubleshootingHOW to Order Repair Parts Parts ListParts View Optional Blower Installation Instructions Optional Blower DRB-1Optional Blower Installation Instructions Service Notes Service Notes