INSTALLATION INSTRUCTIONS (continued)

1.Remove old caulking beneath the collar of the outside mounting plate. Apply new caulking beneath the collar of the outside mounting plate. Use additional caulking to correct uneven wall surface, such as clapboard.

2.Insert six inch air tube on outside mounting plate INTO six inch air tube attached to air drop. Position the outside mounting plate so that six inch air tube has a slight downward slope to the outside. The downward slope is necessary to prevent the entry of rainwater. Attach outside mounting plate to exterior wall with four (4) 10 x 1 1/2" screws.

3.Place four inch flue tube on vent cap OVER four inch flue tube attached to combustion chamber. Attach vent cap to outside mounting plate with three (3) 10 x 1/2" screws.

4.Reassembly and resealing vent-air intake system is completed.

Installing a Vent Near a Window Ledge,

Other Type of Projection or on Siding (vinyl, aluminum, etc.) Direct vent furnaces are designed to be installed on a uniform outside wall. When the wind comes from any angle (up, down or from either side), it must hit the vent cap equally over both the air inlet and the flue outlet portions of the vent. Any wall projection, such as a door or window casing, which disturbs the wind on one side of the air inlet section will result in back pressure on the flue section smothering the flame and eventual pilot outage.

When the vent cap is to be installed on siding or it appears that a projection within 6" of any side of the air inlet section could shield the air inlet section, the entire vent should be supported away from the wall at least the distance of the projection. 2" x 4" framing whose outside dimensions match the overall dimensions of the mounting plate is recommended. The 2" x 4" framing protects siding from possible warpage or discoloration. All joints can then be sealed and painted. The wall depth plus the additional depth of the 2" x 4" framing should not exceed a total depth of 19" for DV-55T. (See Figure 10)

Vinyl siding vent kit, DV-822, is available from Empire Comfort Systems, Inc. The depth is 3", which enables the vent cap to be extended away from siding or projections. The wall depth plus the additional 3" depth of the vinyl siding vent cap extension should not exceed a total depth of 19" for DV-55T. (See Figure 11)

Warning: When vinyl siding vent kit, DV-822 or 2" x 4" framing is added to an existing installation (furnace is installed) do not attempt to add sections of pipe to the flue outlet tube or air inlet tube. An air tight seal is required for both tubes. Refer to Parts List, page 16 to order tubes.

Figure 10

Figure 11

13118-7-0408

Page 11

Image 11
Contents Installation Instructions Table of Contents Vent KIT Information Important Safety InformationLP-GAS Warning Odor Safety Information for Users of LP-GASClear of ALL Obstructions Requirements for MassachusettsIntroduction SpecificationsFeet Installing a New Main Gas CockGAS Supply Locating Gas SupplyClearances ClearancesChecking Manifold Pressure Locating Wall Opening Installation InstructionsInstalling Optional Side Outlets Reassembly And Resealing Vent-Air Intake System Installation of Three-prong Grounding Plug AssemblyUsing Plastic Expansion Anchors Installing Vent AssemblyInstallation Instructions Or explosion Lighting InstructionsMain Burner Flame Characteristics Pilot Flame CharacteristicsThermostat Installation WiringService & Maintenance Suggestions Parts List HOW to Order Repair PartsParts View Service Notes Service Notes Comfort Systems