GAS SUPPLY

Locating Gas Supply

The gas line can enter the unit either through the floor or outside wall. The gas line opening should be made at this time. Location of the opening will be determined by the position of floor joists and the valve and union used for servicing.

3/4" Recommended Gas Pipe Diameter

Pipe Length

Schedule 20 Pipe

Tubing, Type L

(Feet)

Inside Diameter

Outside Diameter

 

Nat.

L.P.

Nat.

L.P.

0-10

1//2"

3/8"

1/2"

3/8"

 

12.7mm

9.5mm

12.7mm

9.5mm

10-40

1/2"

1/2"

5/8"

1/2"

 

12.7mm

12.7mm

15.9mm

12.7mm

40-100

1/2"

1/2"

3/4"

1/2"

 

12.7mm

12.7mm

19mm

12.7mm

100-150

3/4"

1/2"

7/8"

3/4"

 

19mm

12.7mm

22.2mm

19mm

Note: Never use plastic pipe. Check to confirm whether your local codes allow copper tubing or galvanized.

Note: Since some municipalities have additional local codes, it is always best to consult your local authority and installation code.

The use of the following gas connectors is recommended:

ANSZ21.24ApplianceConnectorsofCorrugatedMetalTubing and Fittings

ANS Z21.45 Assembled Flexible Appliance Connectors of Other Than All-Metal Construction

The above connectors may be used if acceptable by the authority havingjurisdiction.ThestateofMassachusettsrequiresthataflexible appliance connector cannot exceed three feet in length.

Figure 1

Consult the current National Fuel Gas Code, ANSI Z223.1 CAN/ CGA-B149 (.1 or .2) installation code.

Installing a New Main Gas Cock

Each appliance should have its own manual gas cock.

A manual main gas cock should be located in the vicinity of the unit. Where none exists, or where its size or location is not adequate, contact your local authorized installer for installation or relocation.

Compounds used on threaded joints of gas piping shall be resistant to the action of liquefied petroleum gases. The gas lines must be checked for leaks by the installer. This should be done with a soap solution watching for bubbles on all exposed connections, and if unexposed, a pressure test should be made.

Never use an exposed flame to check for leaks. Appliance must be disconnected from piping at inlet of control valve and pipe capped or plugged for pressure test. Never pressure test with appliance connected; control valve will sustain damage!

A gas valve and ground joint union should be installed in the gas line upstream of the gas control to aid in servicing. It is required by the National Fuel Gas Code that a drip line be installed near the gas inlet. This should consist of a vertical length of pipe tee connected into the gas line that is capped on the bottom in which condensation and foreign particles may collect.

Figure 2

Method of Installing a Tee Fitting Sediment Trap Pressure Testing of the Gas Supply System

1.To check the inlet pressure to the gas valve, a 1/8" (3mm) N.P.T. plugged tapping, accessible for test gauge connection, must be placed immediately upstream of the gas supply connection to the appliance.

2.The appliance and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 psig (3.5 kPa).

3.The appliance must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig (3.5 kPa).

Attention! If one of the above procedures results in pressures in excess of 1/2 psig (14" w.c.) (3.5 kPa) on the appliance gas valve, it will result in a hazardous condition.

13118-7-0408

Page 7

Image 7
Contents Installation Instructions Table of Contents Vent KIT Information Important Safety InformationLP-GAS Warning Odor Safety Information for Users of LP-GASClear of ALL Obstructions Requirements for MassachusettsIntroduction SpecificationsFeet Installing a New Main Gas CockGAS Supply Locating Gas SupplyChecking Manifold Pressure ClearancesClearances Installing Optional Side Outlets Installation InstructionsLocating Wall Opening Reassembly And Resealing Vent-Air Intake System Installation of Three-prong Grounding Plug AssemblyUsing Plastic Expansion Anchors Installing Vent AssemblyInstallation Instructions Or explosion Lighting InstructionsMain Burner Flame Characteristics Pilot Flame CharacteristicsThermostat Installation WiringService & Maintenance Suggestions Parts List HOW to Order Repair PartsParts View Service Notes Service Notes Comfort Systems