Lennox Hearth EN54-VDLE manual Operation and care of your appliance, Burn-in Period, Adjustment

Page 3

Table 1 shows the units' gas orifice size for the elevations indicated.

Model

Orifice size

Elevation

Feet

No.

 

 

Nat.

Prop.

(meters)

 

ELDV35

#38

#53

0-4500

 

 

 

ELDV40

#37

0.062"

(0-1372)

ELDV45

#36

#52

 

Table 1

Maximum manifold pressure is 3.5 in. w.c. (0.87 kPa) for natural gas and 10 in. w.c. (2.49 kPa) for LP/Propane gas.

Do not use these appliances if any part has been under water. Immediately call a qualified, professional service technician to inspect the appliance and to replace any parts of the control system and any gas control which have been under water.

Ne pas se servir de cet appareil s'il a été plongé dans l'eau, complètement ou en partie. Appeler un technicien qualifié pour inspecter l'appareil et remplacer toute partie du système de con- trôle et toute commande qui ont été plongés dans l'leau.

Test gage connections are provided on the front of the millivolt and electronic gas control valve (identified OUT for the manifold side and IN for inlet pressure. A 1/8" NPT test gage connection is provided on the electronic gas control valve adjacent to the outlet to the main burner.

Minimum inlet gas pressure to these appli- ances is 5.0 inches water column (1.24 kPa) for natural gas and 11 inches water column (2.74 kPa) for propane for the purpose of input

Any safety guard or screen removed for ser- vicing the appliance must be replaced prior to operating the appliance.

Warning: Failure to comply with the installation and operating instructions provided in this document will result in an im- properly installed and operating appliance, voiding its warranty. Any change to this appliance and/or its operating controls is dangerous. Improper instal- lation or use of this appliance can cause serious injury or death from fire, burns, explosion or carbon monoxide poisoning.

Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning are similar to the flu with headaches, dizziness and/or nausea. If you have these signs, obtain fresh air immedi- ately. Turn off the gas supply to the appliance andhaveitservicedbyaqualifiedprofessional, as it may not be operating correctly.

Warning: children and adults should be alerted to the hazards ofhighsurfacetemperatures.Use caution around the appliance to avoid burns or clothing ignition. Young children should be care- fully supervised when they are in the same room as the appliance.

Warning: Do not place clothing or other flammable materials on or near this appliance.

AvertisSement: SURVEILLER LES ENFANTS. GARDER LES VêTEMENTS,

LES MEUBLES, L'ESSENCE OU AUTRES LIQUIDES à VAPEUR INFLAMMABLES LoIN DE L'APPAREIL.

Operation and care of your appliance

Appliance operation may be controlled by the following means: the factory provided unit- mounted ON-OFF control switch, a remotely located optional wall switch or optional remote control. See Figure 1.

Burn-in Period

During the first few fires of this appliance there will be some odor due to the curing of the paint and burning off of lubricants used in the manufacturing process.

Depending on your use, the burn-in period may take a few hours or a few days.

KEEP YOUR HOUSE WELL VENTILATED DURING THE CURING PROCESS. THE ODOR AND HAZE EMITTED DURING THE CURING PROCESS CAN BE QUITE NOTICEABLE AND MAY SET OFF A SMOKE DETECTOR.

If an optional blower is installed, Do not turn it on during the Burn-In period.

A white film may develop on the glass front during the first few fires as part of the curing process. The glass should be kept clean during the first two weeks of use to prevent the film from baking on (making it very difficult to remove). See Glass Cleaning on Page 4.

adjustment.

Maximum inlet gas supply pressure to these appliances is 10.5 inches water column (2.61 kPa) for natural gas and 13.0 inches water column (3.23 kPa) for propane.

The appliance must be isolated from the gas supply piping system (by closing its individual manualshut-offvalve)duringanypressuretesting of the gas supply piping system at test pressures equal to or less than 1/2 psig (3.5 kPa).

The appliance and its individual shut-off valve must be disconnected from the gas supply piping system during any pressure testing of that system at pressures in excess of 1/2 psig (3.5 kPa).

These appliances must not be connected to a chimney or flue serving a separate solid fuel burning appliance.

Gas Line Access Plate Not Installed

 

 

At The Factory. It Is Included In

 

 

The Installation Instruction Bag.

 

 

 

 

ON

 

 

 

 

OFF

 

 

Gas

 

ON/OFF

 

 

Supply

Shut-Off Valve

Switch

Gas Valve

Right Corner Post

Line

 

 

(Orientation

Piezo Ignitor

 

Air Shutter

 

As Shown)

 

Adjustment Arm

 

 

 

Figure 1

 

 

 

 

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

Image 3
Contents Direct Vent Elite Series Table of Contents Adjustment Operation and care of your applianceBurn-in Period Glass Cleaning MaintenanceSIT Millivolt Gas Valve Maintenance Schedule Maintenance Task Accomplishing Person ProcedureAttempt to clean glass while hoT Front Glass Enclosure Panel, Removal and Installation Burner AdjustmentsFlame Appearance and Sooting 11.1 Log PlacementForced Air Kit Accessory ComponentsStandard Remote Control System Deluxe Remote Control SystemHorizontal Termination Shroud Kit ON/OFF Wall Switch KitBag of Glowing Embers Twelve Piece Ember KitDual Arch Screen Kits Screen Panel Kits Model No. Catalog NoWest Taft Avenue Warranty Replacement partsProduct reference information Lennox Hearth ProductsTo Turn OFF GAS to Appliance For Your Safety Read Before LightingLighting Instructions Millivolt GAS Valve Lighting InstructionsInstructions D’ALLUMAGE Vanne GAZ Millivolt Instructions DallumagePour Fermer LE GAZ QUI Alimente L’APPAREIL Lighting Instructions Electronic What to do if YOU Smell GASTo shut off Instructions D’ALLUMAGE Electronic Instructions D’ALLUMAGEPour Éteindre L’APPAREIL Symptom Possible Causes Corrective Action Batteries Low Symptom Possible causes Corrective actionNothing happens when Low voltage/or bad lead Check wire connectionDescription Replacement Parts ListSIT Millivolt Description ELDV35 ELDV40 ELDV45Replacement Parts 875,030M REV. B 05/2008

EN53-VDLE, MN53-VDLE, MN54-VDLE, MP04-VDLE, MP53-VDLE specifications

The Lennox Hearth series, featuring models MN53-VDLE, EN04-VDLE, MN54-VDLE, EN53-VDLE, and MP04-VDLE, represents a remarkable blend of cutting-edge technology and elegant design, making them popular choices for homeowners looking to enhance their living spaces with reliable and stylish heating solutions.

One of the standout features of these models is their versatility in design configurations. Each model offers a range of styles, including traditional and contemporary options, ensuring they can seamlessly integrate into any home decor. The clean, linear designs are complemented by large viewing areas that allow for a captivating flame display, creating a cozy ambiance while heating the home.

The Lennox Hearth series incorporates advanced heating technologies to maximize efficiency and reduce energy consumption. The use of high-efficiency combustion systems helps to produce more heat with less fuel, contributing to lower utility bills while maintaining a comfortable indoor environment. Furthermore, these models are engineered to produce minimal emissions, adhering to stringent environmental standards, making them eco-friendly choices for conscious consumers.

Another important characteristic is the user-friendly operation. Many models in the Lennox Hearth series are equipped with smart technology that allows for easy control through a mobile app or smart home devices. This feature enables homeowners to adjust temperature settings, monitor energy usage, and schedule heating times from anywhere, ensuring optimal comfort tailored to individual lifestyles.

Safety is paramount in the design of the MN53-VDLE, EN04-VDLE, MN54-VDLE, EN53-VDLE, and MP04-VDLE models. They come with built-in safety features such as automatic shut-off systems, glass doors that remain cool to the touch, and robust construction that minimizes the risk of accidental fires.

Durability is another key characteristic of these heating solutions. Made from high-quality materials designed to withstand the test of time, Lennox Hearth products are built for long-lasting performance, ensuring homeowners can enjoy their benefits for years.

In summary, the Lennox Hearth MN53-VDLE, EN04-VDLE, MN54-VDLE, EN53-VDLE, and MP04-VDLE models combine aesthetic appeal with advanced technology and safety features, making them ideal choices for anyone looking to blend style and functionality in their home heating solutions. They are a testament to Lennox's commitment to excellence in design and engineering, providing comfort and warmth in the most appealing way.