Lighting Instructions – Millivolt GAS VALVE

FOR YOUR SAFETY READ BEFORE LIGHTING

WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY

RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.

A.This appliance has a pilot which must be lighted with a piezo ignitor. When lighting the pilot, follow these instructions exactly.

B.BEFORE OPERATING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Extinguish any open flame.

Open windows.

Do not light any appliance.

Do not touch any electrical switches.

Do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone.

If your gas supplier cannot be reached, call the fire depart- ment.

C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, do not try to repair it, call a qualified service technician. Force or attempted repair may result in a fire or an explosion.

D.Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

LIGHTING INSTRUCTIONS

1.STOP! Read the safety information above on this page.

2.Access the lower control compartment.

3.Turn remote wall switch to “OFF.”

4.Verify main line shut-off valve is open.

5.Push in gas control knob slightly and turn clockwise to “OFF.”

6.Wait five (5) minutes to clear out any gas. If you then smell gas, STOP! Follow “B” in the safety information above on this page. If you do not smell gas, go to the next step.

7.Push in gas control knob slightly and turn counterclockwise

to “PILOT.”

8.Push in control knob all the way and hold in. Immediately light the pilot by triggering the spark ignitor (pushing the button) until pilot lights. Continue to hold the control knob in for about 1 Z\x minutes after the pilot is lit. Release knob and it will pop back up. Pilot should remain lit. If it goes out, repeat steps 5 through 8.

TPTH

 

 

 

OUT

 

IN

 

 

 

 

 

 

TP

 

 

IH

 

 

 

 

 

 

 

OFF

 

 

 

 

 

 

P

 

 

 

 

 

 

I

 

 

 

 

L OW

it

L

 

TH

 

 

O

 

 

 

 

T

 

 

 

 

 

 

 

 

 

 

 

N

O

 

 

 

 

 

 

 

 

 

 

P

 

 

 

 

 

I

 

 

 

 

L

 

 

 

 

 

TO

 

 

 

 

 

Note: Knob cannot be turned from “PILOT” to “OFF” unless the knob is pushed in slightly. Do not force.

If knob does not pop up when released, stop and immediately call your service technician or gas supplier.

If pilot will not stay lit after several tries, turn the control knob to “OFF” and call your service technician or gas supplier.

9.Turn gas control knob counterclockwise to “ON.”

10.Close lower control compartment.

12

TO TURN OFF GAS TO APPLIANCE

1.

Turn remote wall switch “OFF.” The pilot will remain lit for nor-

4.

Depress gas control knob slightly and turn clockwise

 

mal service.

 

to “OFF.” Do not force.

2.

For complete shutdown, turn remote wall switch to “OFF.”

5.

Close lower control compartment.

3.Access the lower control compartment.

Image 12
Contents Direct Vent Elite Series Table of Contents Adjustment Operation and care of your applianceBurn-in Period Glass Cleaning MaintenanceSIT Millivolt Gas Valve Maintenance Schedule Maintenance Task Accomplishing Person ProcedureAttempt to clean glass while hoT Front Glass Enclosure Panel, Removal and Installation Burner AdjustmentsFlame Appearance and Sooting Log Placement 11.1Accessory Components Standard Remote Control SystemDeluxe Remote Control System Forced Air KitON/OFF Wall Switch Kit Bag of Glowing EmbersTwelve Piece Ember Kit Horizontal Termination Shroud KitScreen Panel Kits Model No. Catalog No Dual Arch Screen KitsWarranty Replacement parts Product reference informationLennox Hearth Products West Taft AvenueFor Your Safety Read Before Lighting Lighting Instructions Millivolt GAS ValveLighting Instructions To Turn OFF GAS to ApplianceInstructions D’ALLUMAGE Vanne GAZ Millivolt Instructions DallumagePour Fermer LE GAZ QUI Alimente L’APPAREIL Lighting Instructions Electronic What to do if YOU Smell GASTo shut off Instructions D’ALLUMAGE Electronic Instructions D’ALLUMAGEPour Éteindre L’APPAREIL Symptom Possible Causes Corrective Action Symptom Possible causes Corrective action Nothing happens when Low voltage/or bad leadCheck wire connection Batteries LowReplacement Parts List SIT MillivoltDescription ELDV35 ELDV40 ELDV45 DescriptionReplacement Parts 875,030M REV. B 05/2008

EN53-VDLE, MN53-VDLE, MN54-VDLE, MP04-VDLE, MP53-VDLE specifications

The Lennox Hearth series, featuring models MN53-VDLE, EN04-VDLE, MN54-VDLE, EN53-VDLE, and MP04-VDLE, represents a remarkable blend of cutting-edge technology and elegant design, making them popular choices for homeowners looking to enhance their living spaces with reliable and stylish heating solutions.

One of the standout features of these models is their versatility in design configurations. Each model offers a range of styles, including traditional and contemporary options, ensuring they can seamlessly integrate into any home decor. The clean, linear designs are complemented by large viewing areas that allow for a captivating flame display, creating a cozy ambiance while heating the home.

The Lennox Hearth series incorporates advanced heating technologies to maximize efficiency and reduce energy consumption. The use of high-efficiency combustion systems helps to produce more heat with less fuel, contributing to lower utility bills while maintaining a comfortable indoor environment. Furthermore, these models are engineered to produce minimal emissions, adhering to stringent environmental standards, making them eco-friendly choices for conscious consumers.

Another important characteristic is the user-friendly operation. Many models in the Lennox Hearth series are equipped with smart technology that allows for easy control through a mobile app or smart home devices. This feature enables homeowners to adjust temperature settings, monitor energy usage, and schedule heating times from anywhere, ensuring optimal comfort tailored to individual lifestyles.

Safety is paramount in the design of the MN53-VDLE, EN04-VDLE, MN54-VDLE, EN53-VDLE, and MP04-VDLE models. They come with built-in safety features such as automatic shut-off systems, glass doors that remain cool to the touch, and robust construction that minimizes the risk of accidental fires.

Durability is another key characteristic of these heating solutions. Made from high-quality materials designed to withstand the test of time, Lennox Hearth products are built for long-lasting performance, ensuring homeowners can enjoy their benefits for years.

In summary, the Lennox Hearth MN53-VDLE, EN04-VDLE, MN54-VDLE, EN53-VDLE, and MP04-VDLE models combine aesthetic appeal with advanced technology and safety features, making them ideal choices for anyone looking to blend style and functionality in their home heating solutions. They are a testament to Lennox's commitment to excellence in design and engineering, providing comfort and warmth in the most appealing way.