Lennox Hearth EBSTPM-2 Burner Adjustments, Main Burner Factory Shutter Setting, Propane, Models

Page 8

8

WARNING: DO NOT ATTEMPT TO SUBSTI- TUTE THE MATERIALS USED ON THESE DOORS, OR REPLACE CRACKED OR BRO- KEN GLASS WITH ANY MATERIALS OTHER THAN THOSE PROVIDED BY THE APPLI- ANCE MANUFACTURER.

THE GLASS DOORS OF THIS APPLIANCE MUST ONLY BE REPLACED AS A COMPLETE UNIT AS PROVIDED BY THE MANUFACTURER. DO NOT ATTEMPT TO REPLACE BROKEN, CRACKED OR CHIPPED GLASS SEPARATELY.

Refer to Figure 6 and remove the front glass enclosure panel as follows:

1.Remove the top bustle, and the top louver assembly or radiant panel. Then remove the bottom bustle.

2.Open the control compartment access panel. To open the control compartment access panel, actuate the spring-loaded magnetic catches securing the panel, by gently depressing the outer top corners of the panel until the catches "pop" the door free, allowing it to swing out and down to open.

3.Remove the bottom control compartment access panel by compressing the spring-loaded hinge pin on the left side until it disengages from the left cabinet corner post hole. Pull the panel away from the fireplace.

4.Once the control compartment access panel has been removed, the modesty panel can be removed as follows: pull the bottom right corner of the modesty panel out slightly to disengage the snap-fit feature; lift the modesty panel by the tab on the panel's right end, pull the right end of the panel away from the cabinet and then pull the panel diagonally out of the left side cabinet panel slots. (In the above procedure, reverse the words "left" and "right" for EBCR-2 models).

Remove the modesty panel carefully, so that none of the wires become loose or discon- nected. Now complete access to the gas control valve and its related controls is attainable.

Lower Compartment Door and Hinge

Modesty Panel

Top Flange

(Glass Enclosure

 

 

Panel Frame)

 

Front Glass

 

Enclosure Panel

Glass

Enclosure

Panel

Latch

Bottom Vee-flange

 

(Glass Enclosure

Firebox Floor

Panel Frame)

EBST-2 SHOWN

 

Figure 6

 

5.Locate the latch at the top of the control compartment. To disengage the latch from the bottom vee-flange of the glass enclosure panel, reach for the handle located towards the back of the latch and pull the handle down towards the front of the unit.

6.Swing the bottom of the door out and raise it slightly to lift the top flange of the door frame away from the appliance.

To install the front glass enclosure panel, proceed as follows:

1.Visually inspect the gasket on the backside of the panel. The gasket surface must be clean, free of irregularities and seated firmly.

2.Position the glass enclosure panel in front of the firebox opening at a 45 degree angle and engage the top flange over the lip at the top of the firebox opening.

3.Swing the glass enclosure panel down and back. Ensure the gasket seats evenly as the panel draws shut. Engage the Vee-flange at the bottom of the panel with the latch and then close the latch to secure the panel.

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

4.Reinstall the modesty panel by inserting the tongues on the left side of it into the slots on the left side cabinet panel. Swing the right side of the modesty panel towards the unit. Engage the hook on the right side of the modesty panel with the right side cabinet panel slot. Gently press the bottom right corner of the modesty panel to engage the snap-fit feature.

(The left and right designations used here are reversed in EBCR-2 applications.)

5.Reinstall the bottom control compartment access panel by inserting the right side locat- ing pin into the right side cabinet panel and then the left side spring-loaded pin into the left side cabinet panel.

6.Reinstall the top and bottom bustle, and the top louver assembly or radiant panel.

Burner Adjustments

Note - The air shutter for the burner primary air opening is factory-set. Do not adjust the fac- tory-set position. The factory-set position is shown in Figure 7.

*Air Shutter

Burner

Opening

Venturi

 

Tube

 

Orifice

*Note - Do Not Adjust the Factory-Set Position. Eachofthetwoairshutters(oneforeachburner)are open the amount shown in the table, below.

MAIN BURNER

FACTORY SHUTTER SETTING

 

Natural Gas

Propane

 

Gas

Models

inches

inches

 

(mm)

 

(mm)

 

 

EBST-2

 

 

EBPF-2

 

 

EBCR-2

1/16 (1.5)

5/16 (8)

EBCL-2

 

 

EBBAY

 

 

Figure 7

Image 8
Contents Retain These Instructions For Future Reference Table of Contents CongratulationsControl Compartment Access Millivolt Control Valve Shown Operation and Care of Your ApplianceGasControls/ControlCompartmentAccess Millivolt AppliancesElectronic Appliances Manifold Pressure Port Variable Flame Height Adjustment Millivolt Appliances only Venting Action and Safety Limit Operation Outside Combustion Air Controls Outside Air Control Lever Securing Screw LocationMaintenance Front Glass Enclosure Panel, Removal and InstallationManual-Reset Safety Limit Switch Safety Switch Location EBCL-2 ShownClean Glass While IT is HOT Maintenance ScheduleMaintenance Task Accomplishing Person Procedure Burner Adjustments Main Burner Factory Shutter SettingPropane ModelsLog Placement Install the unitized log setBurner Positioning Bottom of the log set is notched to accommodate the pilotWarranty Replacement PartsLennox Hearth Products Product Reference InformationAccessory Components Standard Remote Control System Model RCLON/OFF Wall Switch Kit Door Frame KitsDeluxe Remote Control System Model RCL-T Accessory ComponentsCharcoal Finish Louvers Kits Polished Brass and Brushed Stainless Hood KitsPiece Polished Brass and Brushed Stainless Louvers Kits Polished Brass and Brushed Stainless Louvers KitsScreen Panel Kit Touch-Up Paint KitLighting Instructions Millivolt GAS Valve Lighting InstructionsTo Turn OFF GAS to Appliance What to do if YOU Smell GASPour Fermer LE GAZ QUI Alimente L’APPAREIL Instructions D’ALLUMAGE Vanne GAZ MillivoltInstructions Dallumage Lighting Instructions Electronic What to do if YOU Smell GASTo Shut OFF Front ViewInstructions D’ALLUMAGE Electronic Instructions D’ALLUMAGEPour Éteindre L’APPAREIL Pour Fermer LE GAZ QUI Alimente L’APPAREILSymptom Possible Causes Corrective Action Troubleshooting the Electronic Ignition System Check vent system for obstructionsGAS Controls SIT Millivolt GAS Controls Honeywell ElectronicGAS Orifices SIT and Honeywell Systems DescriptionNatural and Propane Qty Replacement Parts ListDescription 11a 11b 31 37 13a 13b3a10 Cabinet Corner Post Location Rear Burner Front BurnerPage 875,012M REV. D 05/2004