Lennox Hearth L20 DVF-2 manual Model L20 BF-2 only, Vent Configuration Requirements

Page 11

INSTALLATION

MODEL L20 BF-2 ONLY

This appliance is designed to be vented with a 4” B-Vent pipe. Each B-Vent appliance must use its own separate vent system. For pipe clearances, also see pipe manufacturers venting instructions.

B-Vent Installation Illustration

Approved for vertical termination only.

 

Vertical

 

Termination

Firestops must be

Only

used when vent

 

pipe passes

 

through a floor or

 

ceiling

 

Horizontal runs

25

Feet

require ¼” rise

Max.

per foot.

 

See chart

5 Feetbelow to

Min.determine horizontal run allowed

Model L20 BF-2

Maximum Horizontal Pipe Runs

for Given Vertical Pipe Run (in feet)

Vertical run

5’

6’

8’

10’

15’

20’

in feet

 

 

 

 

 

 

 

 

 

 

 

 

 

Maximum horizon-

4’

6’

8’

10’

15’

20’

tal run in feet

 

 

 

 

 

 

 

 

 

 

 

 

 

Note: Maximum allowable horizontal pipe run is 20 feet.

Vent Configuration Requirements

A minimum of 5 feet vertical pipe is required to vent the ap- pliance. Lengthy horizontal pipe runs require sufficient length of vertical pipe to deliver adequate draft. Use the table above as a guide in planning your installation. The use of multiple 45° or 90° elbows should be compensated by providing addi- tional vertical pipe run.

The B-Vent unit has a 4” B-Vent flue collar and may be in- stalled with listed B-Vent piping and components. Refer to the pipe manufacturer’s installation instructions for specific requirements for their product. Maintain proper clearances to combustible materials as specified by the pipe manufacturer. Whenever vent pipe is run horizontally, maintain a minimum 1/4” rise per foot. Exterior B-Vent exhaust systems should be enclosed in a chase to avoid rapid cooling of exhaust gases in the vent. Such cooling could produce condensation of flue gases or exhaust gas spillage. The use of a chase is highly recommended in colder climates.

Notes:

Maximum total offsets allowed: Not to exceed 180 de- grees.

Also see pipe manufacturers instructions for additional vent installation requirements.

Horizontal vent clearances: 3“ minimum top, 1“ mini- mum on bottom and sidewalls.

Vertical vent clearances: 1” minimum.

Install vent support brackets every 4 feet of vertical pipe unless otherwise specified by vent manufacturer.

For vent termination requirements, see page 10

PAGE 11

Image 11
Contents 775,021M Rev. C, 8/04 Freestanding Vented GAS Fired Room HeatersRetain this Manual for Future Reference Important Warnings / Cautions Table of Contents LOW High Planning Your InstallationLocal and National Code Requirements Tool / Equipment ListQuestions to ASK the Local Building Official Corner Manufactured Mobile Home RequirementsImportant Notes Rear Wall or AlcoveHorizontal Termination With 1 Offset Vertical Termination with no OffsetsVertical Termination With 2 Offsets Direct Vent System Components Model L20 DVF-2 only InstallationSV4MCK Installation Model L20 DVF-2 onlyCony For vent termination requirements, see Vent Configuration RequirementsModel L20 BF-2 only Supply Line Size Requirements Pressure TestingGAS Supply Hookup ALL Models Door Operation ALL Models Glowing Embers GAS Appliance Final Assembly ALL ModelsInstalling LOG SET Verify that the gas line has been purged of air Installation Check List ALL ModelsLighting and Shutdown Instructions ALL Models For Your Safety Read Before LightingCare and Operation Gas Control KnobsCirculation Blower Operation ALL Models BREAK-IN PeriodCombustion Chamber Relief Door Canada Parts ListPropane Conversion Procedure Propane ConversionBurner Flame Appearance Reference InformationMaintenance Pilot Flame Appearance Air Shutter AdjustmentALL Models Periodic Check of Pilot and Burner Flames Cycle unit a minimum of 2 timesModel L20 BF-2 Model L20 DVF-2 Wiring DiagramsGAS Control and Safety System Wiring Diagram ALL Models Troubleshooting Qualified Technicians OnlySpillage Test Procedure Model L20 BF-2 only Spill SwitchTroubleshooting Check List Qualified Technicians Only Item # Catalog # Description Where Used Replacement Parts Models L20BF-2 & L20 DVF-2Item # Catalog # Model Description Optional Accessories Models L20BF-2 & L20 DVF-2Top View Side View Specifications Model L20 BF-2Specifications Model L20 DVF-2 SAFETY/ Listing Label Rating Plate SAFETY/ Listing Label Rating Plate Ownership Records Service and Maintenance LOG775,021M REV. C 08/2004

L20 DVF-2, L20 BF-2 specifications

The Lennox Hearth L20 DVF-2 and L20 BF-2 are two innovative gas fireplaces that offer modern heating solutions for homes looking to combine functionality, style, and efficiency. Both models are designed with advanced technology to deliver reliable performance and aesthetics that enhance any living space.

The L20 DVF-2 is a direct vent fireplace that utilizes a sealed combustion system, allowing it to operate efficiently without drawing air from the room. This feature not only improves energy efficiency but also helps maintain indoor air quality since outside air is used for combustion. One of its standout features is the ability to provide a range of heat output options, allowing homeowners to adjust the warmth to their preference. The fireplace comes with a convenient remote control, enabling effortless operation from anywhere in the room.

The L20 BF-2, on the other hand, is a conventional vent fireplace, offering a different installation option ideal for various home designs. Similar to the DVF-2, the BF-2 model provides a wide range of heat output, ensuring comfort in chilly conditions. It features a striking design with a large viewing area, allowing for a mesmerizing flame display that serves as a focal point in any room.

Both models are equipped with Lennox's patented Powerflow technology, which optimizes heat distribution throughout the space. This technology not only enhances comfort but also ensures that energy is used efficiently. The fireplaces also feature easy-to-use controls and customizable flame height settings, giving users precise control over their heating experience.

In terms of design, the L20 DVF-2 and L20 BF-2 come in various finishes and styles, allowing them to seamlessly blend with different home aesthetics. Their sleek and contemporary appearance complements modern interiors, while still fitting into more traditional décor in subtle ways.

Overall, the Lennox Hearth L20 DVF-2 and L20 BF-2 provide effective heating solutions paired with advanced technologies and stylish designs. Whether a homeowner desires a direct vent option or a traditional vent fireplace, both models deliver energy-efficient performance, exceptional heat distribution, and a stunning flame display that can enhance the ambiance of any living space. These fireplaces are not just heating appliances; they are an investment into comfort and elegance for years to come.