MAINTENANCE

Always Turn Off Gas Control Valve Before Cleaning. Annual Maintenance Should Only Be Performed By A Qualified Service Technician:

(ALL MODELS)

LOG SET

Removing & Cleaning Logs - Carefully remove the logs (remov- ing top logs, then lifting front log out, then rear log). Use care when handling the fiber logs, as they become quite fragile after curing. Use a small soft-bristled brush (e.g., a nylon paint brush) to remove soot, dust or debris that may have accumu- lated on the burner or log set. Remove the logs and burner, and clean them outside the home in a location with plenty of fresh air ventilation. Avoid breathing fine particulates of dust that may be generated. See page 14, Installing Log Set for instruc- tions on reinstalling logs.

Replacing Logs - If logs become damaged by accident or im- proper handling and need replacement, use only the proper re- placement logs from manufacturer, which can be purchased from your local dealer. See Page 25.

CLEANING BURNER

With the logs removed, vacuum out any foreign matter (lint, carbon etc.) on the burner. Be sure the burner ports are “open.”

CLEANING VALVE / AIR VENTURI

Clean all lint and dust build-up around the control valve and air shutter on the venturi. Inspect and clean with a brush or wire the inlet of the venturi for any spider webs or lint accumulation.

Burner Assembly

Air Shutter

Ensure opening is clear from lint, dust, spider webs, debris, etc.

INSPECT WIRING / CAUTIONS:

1)Label all wires prior to disconnection when servicing con- trols. Wiring errors can cause improper and dangerous op- eration.

2)Verify proper operation after servicing.

3)Inspect and clean all wire connections. Ensure that there is no melting or damage from rodents. Inspection should in- clude:

Terminals at the valve

On / Off switch

Wall Thermostat / Remote Control (optional kits)

VENTING SYSTEM

A periodic examination of the venting system must be per- formed to ensure that the flow of combustion and ventilation air is not obstructed (outlet and inlet is open and free from block- age). We recommend that you have your gas appliance checked yearly by your independent Lennox dealer.

(Model L20 DVF-2) If the vent-air intake system is disassembled for any reason, the service technician should follow vent manu- factures instructions for proper reassembly and sealing of the vent-air intake system.

IMPORTANT – APPLIANCES INSTALLED USING SIMPSON DURA-VENT BRAND PIPE MUST SEAL ALL JOINTS WITH MILL-PAC BLACK, HIGH TEMPERATURE SEALANT.

CLEAN EXTERNAL SURFACES

External surfaces should be kept clean and dust removed form air inlets to the appliance. The flow of combustion and ventila- tion air must not be obstructed. The appliance must be kept clear and free from combustible materials, gasoline and other flammable vapors and liquids.

SMALL AREA PAINT TOUCH-UP

The stove body is painted with a quality high-temperature stove paint. Use only model TSPK-C Stove Paint, Catalog # 19L92. Do not touch-up this appliance with any other paint.

Using one small piece of 320 grit sand paper and lightly sand the blemish so that the edges are “feathered” or smooth to the touch between the painted and bare surfaces. Do not let the sand paper gum up with paint, as this will cause scratches on the metal surface. If there are any scratches, use 600 grit sand- paper instead. Mask off surfaces you do not want painted. Paint lightly over the bare surface first as this will act as an undercoat. Then paint over a larger area in smooth even strokes to blend.

See Break-In Period on page 17 for information on curing the paint.

CLEANING GLASS

The window on the gas appliance is made from a clear ceramic material and may be cleaned when cool with any non-abrasive product designed for use on glass windows. Do not use abra- sive cleaners on glass. The viewing glass should be cleaned periodically. Exterior glass may be cleaned with a glass cleaner as desired. Interior glass - use soap and water, or commercial glass cleaner recommended for stove glass.

Note: Each time the appliance is lit, it may cause condensation and fog on the glass. This condensation and fog will disappear in a few minutes.

CLEANING BLOWER INTAKE

The blower air intake requires cleaning at least once a year to remove lint, dust, etc. If there are pets in the dwelling, the intake should be cleaned at least twice a year.

PAGE 20

Image 20
Contents 775,021M Rev. C, 8/04 Freestanding Vented GAS Fired Room HeatersRetain this Manual for Future Reference Important Warnings / Cautions Table of Contents Planning Your Installation Local and National Code RequirementsTool / Equipment List LOW HighQuestions to ASK the Local Building Official Manufactured Mobile Home Requirements Important NotesRear Wall or Alcove CornerHorizontal Termination With 1 Offset Vertical Termination with no OffsetsVertical Termination With 2 Offsets Installation Direct Vent System Components Model L20 DVF-2 onlyInstallation Model L20 DVF-2 only SV4MCKCony For vent termination requirements, see Vent Configuration RequirementsModel L20 BF-2 only Supply Line Size Requirements Pressure TestingGAS Supply Hookup ALL Models Door Operation ALL Models Glowing Embers GAS Appliance Final Assembly ALL ModelsInstalling LOG SET Installation Check List ALL Models Verify that the gas line has been purged of airALL Models For Your Safety Read Before Lighting Care and OperationGas Control Knobs Lighting and Shutdown InstructionsCirculation Blower Operation ALL Models BREAK-IN PeriodCombustion Chamber Relief Door Parts List Propane Conversion ProcedurePropane Conversion CanadaReference Information Burner Flame AppearanceMaintenance Air Shutter Adjustment ALL Models Periodic Check of Pilot and Burner FlamesCycle unit a minimum of 2 times Pilot Flame AppearanceModel L20 BF-2 Model L20 DVF-2 Wiring DiagramsGAS Control and Safety System Wiring Diagram Troubleshooting Qualified Technicians Only ALL ModelsSpillage Test Procedure Model L20 BF-2 only Spill SwitchTroubleshooting Check List Qualified Technicians Only Replacement Parts Models L20BF-2 & L20 DVF-2 Item # Catalog # Description Where UsedOptional Accessories Models L20BF-2 & L20 DVF-2 Item # Catalog # Model DescriptionSpecifications Model L20 BF-2 Top View Side ViewSpecifications Model L20 DVF-2 SAFETY/ Listing Label Rating Plate SAFETY/ Listing Label Rating Plate Service and Maintenance LOG Ownership Records775,021M REV. C 08/2004

L20 DVF-2, L20 BF-2 specifications

The Lennox Hearth L20 DVF-2 and L20 BF-2 are two innovative gas fireplaces that offer modern heating solutions for homes looking to combine functionality, style, and efficiency. Both models are designed with advanced technology to deliver reliable performance and aesthetics that enhance any living space.

The L20 DVF-2 is a direct vent fireplace that utilizes a sealed combustion system, allowing it to operate efficiently without drawing air from the room. This feature not only improves energy efficiency but also helps maintain indoor air quality since outside air is used for combustion. One of its standout features is the ability to provide a range of heat output options, allowing homeowners to adjust the warmth to their preference. The fireplace comes with a convenient remote control, enabling effortless operation from anywhere in the room.

The L20 BF-2, on the other hand, is a conventional vent fireplace, offering a different installation option ideal for various home designs. Similar to the DVF-2, the BF-2 model provides a wide range of heat output, ensuring comfort in chilly conditions. It features a striking design with a large viewing area, allowing for a mesmerizing flame display that serves as a focal point in any room.

Both models are equipped with Lennox's patented Powerflow technology, which optimizes heat distribution throughout the space. This technology not only enhances comfort but also ensures that energy is used efficiently. The fireplaces also feature easy-to-use controls and customizable flame height settings, giving users precise control over their heating experience.

In terms of design, the L20 DVF-2 and L20 BF-2 come in various finishes and styles, allowing them to seamlessly blend with different home aesthetics. Their sleek and contemporary appearance complements modern interiors, while still fitting into more traditional décor in subtle ways.

Overall, the Lennox Hearth L20 DVF-2 and L20 BF-2 provide effective heating solutions paired with advanced technologies and stylish designs. Whether a homeowner desires a direct vent option or a traditional vent fireplace, both models deliver energy-efficient performance, exceptional heat distribution, and a stunning flame display that can enhance the ambiance of any living space. These fireplaces are not just heating appliances; they are an investment into comfort and elegance for years to come.