Lennox Hearth L20 DVF-2 manual Care and Operation, ALL Models For Your Safety Read Before Lighting

Page 16

CARE AND OPERATION

(ALL MODELS)

FOR YOUR SAFETY READ BEFORE LIGHTING

WARNING: If you do not follow these instructions ex- actly, a fire or explosion may result causing property damage, personal injury or loss of life.

A.This appliance has a pilot which must be lit. When lighting the pilot, follow these instructions exactly.

B.BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS:

Do not try to light any appliance.

Do not touch any electric switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don’t try to repair it, call a qualified service technician. Force or attempted repair may result in a fire or explosion.

D.Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

Gas Control Knobs

Pilot Adjustment Screw

Convertible HI/LO

 

Regulator

Regulator

 

 

Cap

Piezo Igniter

Inlet

Wiring

 

Pressure

Terminals

 

 

Tap

Outlet Pressure Tap

 

Pilot Assembly

Thermocouple

Igniter

Pilot

Thermopile

 

Electrode

Hood

 

LIGHTING AND SHUTDOWN INSTRUCTIONS

1.STOP! Read the safety information on this page or on label (on ap- pliance).

2.Turn off all electrical power to the appliance (unplug blower power cord). Make sure the burner ON/OFF switch is in the OFF position.

3.To gain access to the gas controls, swing the control access door open. The control access door is located directly under the window.

4.Push in gas control knob slightly and turn clockwise 3to “OFF.” NOTE: Knob cannot be turned from “PILOT” to “OFF” unless knob is pushed in slightly. Do not force.

5.Wait five (5) minutes to clear out any gas. Then smell for gas, in- cluding near the floor. If you smell gas, STOP! Follow “B” in the safety information above on this label. If you don’t smell gas, go to the next step.

6.Visually locate the pilot located in the center of the firebox beneath the rear ceramic log.

7.Turn knob on gas control counterclockwise 4to “PILOT.”

8.This appliance contains a spark ignition system (piezo igniter), which is used to light the pilot. Push in the gas control knob all the way and hold it in. Immediately press the button on the piezo igniter located to the left of the gas control knob. The spark produced by the piezo igniter should light the pilot. Continue to hold the control knob in for about one (1) minute after the pilot is lit. Release the gas control

knob and it will pop back up. Pilot should remain lit.

If it goes out, repeat steps 4 through 8.

If the knob does not pop up when released, stop and immediately

call your service technician or gas supplier.

If the pilot will not stay lit after 3 or 4 tries, turn the gas control knob to “OFF” and call your service technician or gas supplier.

1.Turn gas control counterclockwise 4 to “ON.” Use rocker switch, located either on the control panel or the exterior side panel, to operate main burner. Adjust variable pressure dial (RB Regulator / Flame Height Control) to set burner flame to desired heat output.

2.Swing the control access door closed.

3.Turn on electrical power to the appliance (plug in blower power cord. See page 17, Circulation Blower Operation.)

TO TURN OFF GAS TO THE APPLIANCE

1.Turn off all electric power to the appliance if service is to be per- formed.

2.To gain access to the gas controls, swing the control access door open. The control access door is located directly under the window.

3.Push in gas control knob slightly and turn clockwise 3to “OFF.” NOTE: Knob cannot be turned from “PILOT” to “OFF” unless knob is pushed in slightly. Do not force.

4.Swing the control access door closed.

PAGE 16

Image 16
Contents Retain this Manual for Future Reference Freestanding Vented GAS Fired Room Heaters775,021M Rev. C, 8/04 Important Warnings / Cautions Table of Contents Planning Your Installation Local and National Code RequirementsTool / Equipment List LOW HighQuestions to ASK the Local Building Official Manufactured Mobile Home Requirements Important NotesRear Wall or Alcove CornerVertical Termination With 2 Offsets Vertical Termination with no OffsetsHorizontal Termination With 1 Offset Installation Direct Vent System Components Model L20 DVF-2 onlyInstallation Model L20 DVF-2 only SV4MCKCony Model L20 BF-2 only Vent Configuration RequirementsFor vent termination requirements, see GAS Supply Hookup ALL Models Pressure TestingSupply Line Size Requirements Door Operation ALL Models Installing LOG SET GAS Appliance Final Assembly ALL ModelsGlowing Embers Installation Check List ALL Models Verify that the gas line has been purged of airALL Models For Your Safety Read Before Lighting Care and OperationGas Control Knobs Lighting and Shutdown InstructionsCombustion Chamber Relief Door ALL Models BREAK-IN PeriodCirculation Blower Operation Parts List Propane Conversion ProcedurePropane Conversion CanadaReference Information Burner Flame AppearanceMaintenance Air Shutter Adjustment ALL Models Periodic Check of Pilot and Burner FlamesCycle unit a minimum of 2 times Pilot Flame AppearanceGAS Control and Safety System Wiring Diagram Wiring DiagramsModel L20 BF-2 Model L20 DVF-2 Troubleshooting Qualified Technicians Only ALL ModelsTroubleshooting Check List Qualified Technicians Only Model L20 BF-2 only Spill SwitchSpillage Test Procedure Replacement Parts Models L20BF-2 & L20 DVF-2 Item # Catalog # Description Where UsedOptional Accessories Models L20BF-2 & L20 DVF-2 Item # Catalog # Model DescriptionSpecifications Model L20 BF-2 Top View Side ViewSpecifications Model L20 DVF-2 SAFETY/ Listing Label Rating Plate SAFETY/ Listing Label Rating Plate Service and Maintenance LOG Ownership Records775,021M REV. C 08/2004

L20 DVF-2, L20 BF-2 specifications

The Lennox Hearth L20 DVF-2 and L20 BF-2 are two innovative gas fireplaces that offer modern heating solutions for homes looking to combine functionality, style, and efficiency. Both models are designed with advanced technology to deliver reliable performance and aesthetics that enhance any living space.

The L20 DVF-2 is a direct vent fireplace that utilizes a sealed combustion system, allowing it to operate efficiently without drawing air from the room. This feature not only improves energy efficiency but also helps maintain indoor air quality since outside air is used for combustion. One of its standout features is the ability to provide a range of heat output options, allowing homeowners to adjust the warmth to their preference. The fireplace comes with a convenient remote control, enabling effortless operation from anywhere in the room.

The L20 BF-2, on the other hand, is a conventional vent fireplace, offering a different installation option ideal for various home designs. Similar to the DVF-2, the BF-2 model provides a wide range of heat output, ensuring comfort in chilly conditions. It features a striking design with a large viewing area, allowing for a mesmerizing flame display that serves as a focal point in any room.

Both models are equipped with Lennox's patented Powerflow technology, which optimizes heat distribution throughout the space. This technology not only enhances comfort but also ensures that energy is used efficiently. The fireplaces also feature easy-to-use controls and customizable flame height settings, giving users precise control over their heating experience.

In terms of design, the L20 DVF-2 and L20 BF-2 come in various finishes and styles, allowing them to seamlessly blend with different home aesthetics. Their sleek and contemporary appearance complements modern interiors, while still fitting into more traditional décor in subtle ways.

Overall, the Lennox Hearth L20 DVF-2 and L20 BF-2 provide effective heating solutions paired with advanced technologies and stylish designs. Whether a homeowner desires a direct vent option or a traditional vent fireplace, both models deliver energy-efficient performance, exceptional heat distribution, and a stunning flame display that can enhance the ambiance of any living space. These fireplaces are not just heating appliances; they are an investment into comfort and elegance for years to come.