Lennox Hearth CI1500DVF Tables 3 and 4 show the units gas pressure requirements, Gas Controls

Page 3

Tables 3 and 4 show the units' gas pressure requirements

Inlet Gas Supply Pressure

(all models)

Fuel #

 

 

Minimum

Maximum

Natural Gas

 

4.5" WC

10.5" WC

 

(1.12 kPa)

(2.61 kPa)

 

 

 

 

 

 

 

 

 

Propane

 

 

11.0" WC

13.0" WC

 

 

(2.73 kPa)

(3.23 kPa)

 

 

 

 

 

 

 

 

 

Table 3

 

 

 

 

 

 

 

 

Manifold Gas Supply Pressure

 

 

(millivolt models)

 

 

 

 

 

 

Fuel #

 

 

Low

 

High

 

 

 

 

Natural

(Lo) 1.6" WC

 

(Hi) 3.5" WC

Gas

 

 

(.40 kPa)

 

(.87 kPa)

Propane

(Lo) 6.3" WC

 

(Hi) 10.0" WC

 

(1.57 kPa)

 

(2.49 kPa)

 

 

 

Table 4

Do not use these appliances if any part has been under water. Immediately call a qualified, professional service technician to inspect the appliance and to replace any parts of the control system and any gas controls which have been under water.

Ne pas se servir de cet appareil s'il a été plongé dans l'eau, complètement ou en partie. Appeler un technicien qualifié pour inspecter l'appareil et remplacer toute partie du système de contrôle et toute commande qui ont été plongés dans l'leau.

Test gage connections are provided on the front of the millivolt gas control valve (identified IN for the inlet and OUT for the manifold side).

These appliances must be isolated from the gas supply piping system (by closing their individual manual shut-off valve) during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig (3.5 kPa).

These appliances and their individual shut-off valves must be disconnected from the gas supply piping system during any pressure testing of that system at pressures in excess of 1/2 psig (3.5 kPa).

These appliances must not be connected to a chimney or flue serving a separate solid fuel burning appliance.

CARBON MONOXIDE POISONING: EARLY SIGNS OF CARBON MONOXIDE POISONING ARESIMILARTOTHEFLUWITHHEADACHES, DIZZINESS AND/OR NAUSEA. IF YOU HAVE THESE SIGNS, OBTAIN FRESH AIR IMMEDI- ATELY. TURN OFF THE GAS SUPPLY TO THE APPLIANCE AND HAVE IT SERVICED BY A QUALIFIED PROFESSIONAL, AS IT MAY NOT BE OPERATING CORRECTLY.

WARNING: FAILURE TO COMPLY WITH THE INSTALLATION AND OPERATING INSTRUC- TIONSPROVIDEDINTHISDOCUMENTWILL RESULT IN AN IMPROPERLY INSTALLED AND OPERATING APPLIANCE, VOIDING ITS WARRANTY. ANY CHANGE TO THIS APPLI- ANCE AND/OR ITS OPERATING CONTROLS ISDANGEROUS. IMPROPERINSTALLATION OR USE OF THIS APPLIANCE CAN CAUSE SERIOUS INJURY OR DEATH FROM FIRE, BURNS, EXPLOSION OR CARBON MONOX- IDE POISONING.

WARNING: CHILDREN AND ADULTS SHOULD BE ALERTED TO THE HAZARDS OF HIGH SURFACE TEMPERATURES. USE CAUTION AROUND THE APPLIANCE TO AVOID BURNS OR CLOTHING IGNITION. YOUNGCHILDRENSHOULDBECAREFULLY SUPERVISEDWHENTHEYAREINTHESAME ROOM AS THE APPLIANCE.

WARNING: DO NOT PLACE CLOTHING OR OTHER FLAMMABLE MATERIALS ON OR NEAR THIS APPLIANCE.

AVERTISSEMENT: SURVEILLER LES ENFANTS. GARDER LES VÊTEMENTS, LES MEUBLES, L'ESSENCE OU AUTRES LIQUIDES À VAPEUR INFLAMMABLES LOIN DE L'APPAREIL.

OPERATION AND CARE OF YOUR APPLIANCE

Appliance operation may be controlled through a remotely located optional wall thermostat or remote control.

In lieu of remote or remote wall thermostat operation, the appliance must be operated directly through the on/off rocker switch located on the upper right side of the rear shield. See Figure 1.

If your millivolt appliance is equipped with an optional wall thermostat kit or remote control kit and the pilot is lit, the appliance main burner may be turned on and off with the wall thermostat or remote control.

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

Always keep the appliance area clear and free from combustible materials, gasoline and other flammable liquids.

Remember, Millivolt appliances have a continu- ous burning pilot flame. Exercise caution when using products with combustible vapors.

Gas Controls

Burner On/Off Switch

Burner

On /Off

Switch

Top View

Front

Figure 1

Control Compartment Access

The gas controls can be found behind the lower access door. To access, pull the door open (see Figure 2).

Lower Access Door

Pull open lower door to access Valve Contols

Lower Access

Door

Figure 2

Millivolt appliances will be fitted with the gas control valve shown in Figure 3. Familiarize yourself with the gas control valve that your appliance uses.

SIT Millivolt Gas Valve Controls

 

HI / LO Knob

 

 

Inlet

Variable Flame Height Adjustment

 

Pressure

 

Manifold Pressure Port

Port

 

 

 

 

OUT

 

IN

TPTH

 

 

 

 

TP

IH

 

 

 

 

OF

 

 

 

 

P

 

 

 

 

 

 

 

 

I

 

TH

L OW

 

L

 

it

O

 

 

 

NO

T

 

 

 

 

 

 

P

 

 

F

 

 

 

 

 

LI

 

 

 

 

TO

 

 

 

 

 

 

Main Gas

 

 

Control Knob

Figure 3

 

Piezo Igniter

 

3

Image 3
Contents Pour Réduire AU Minimum LE Risque D’INCENDIE Table of Contents Operation and Care of Your Appliance Control Compartment AccessLower Access Door Tables 3 and 4 show the units gas pressure requirementsModels with Porcelain Enamel Finish MaintenanceGlass Cleaning Verify Proper Operation After ServicingMaintenance Task Accomplishing Person Procedure Maintenance ScheduleBurner Flame Appearance Front Glass Enclosure Panel, Removal and InstallationBurner Adjustments Reinstall TrivetAir Shutter Adjustment Guidelines Burner Air Shutter AdjustmentLog Placement Rear Log StoppersLeft Top Twig Small Area Paint Touch-up Do not Place Embers on TOP of the Burner SlotsSIT Millivolt Appliance Checkout Proper Pilot Flame AppearanceProduct Reference Information Wiring DiagramsWarranty Information Replacement PartsAccessory Components Warming Shelves Brickaded Liner KitsTo Pilot To Turn OFF GAS to ApplianceThis appliance has a pilot which must be lighted with a SIT Millivolt Gas ValvePour Fermer LE GAZ QUI Alimente L’APPAREIL Instructions DallumageSymptom Possible Causes Corrective Action Gas Controls Replacement Parts ListCast Body Components Room Air Blower System Optional Kit 1314 4252021 29b Optional Warming Shelves Kit Reference Information