Lennox Hearth CI2500DVF, CI1500DVF manual Log Placement, Rear Log Stoppers, Left Top Twig

Page 8

8

Log Placement

WARNING: LOGS GET VERY HOT AND WILL REMAIN HOT UP TO ONE HOUR AFTER GAS SUPPLY IS TURNED OFF. HANDLE ONLY WHEN LOGS ARE COOL. TURN OFF ALL ELECTRICITY TO THE APPLIANCE BEFORE YOU INSTALL LOGS.

WARNING: THIS APPLIANCE IS NOT MEANT TO BURN WOOD. ANY ATTEMPT TO DO SO COULD CAUSE IRREPA- RABLE DAMAGE TO YOUR APPLIANCE AND PROVE HAZARDOUS TO YOUR SAFETY.

WARNING: THE SIZE AND POSITION ON THE LOG SET WAS ENGINEERED TO GIVE YOUR APPLIANCE A SAFE, RELIABLE AND ATTRACTIVE FLAME PATTERN. ANY ATTEMPT TO USE A DIFFERENT LOG SET IN THE STOVE WILL VOID THE WARRANTY AND WILL RESULT IN INCOMPLETE COMBUSTION, SOOTING, AND POOR FLAME QUALITY.

WARNING: IF LOGS ARE NOT INSTALLED ACCORDING TO THE DIRECTIONS SHOWN HERE, FLAME IMPINGEMENT AND IMPROPER COMBUSTION COULD OCCUR AND RESULT IN SOOT AND/OR EXCESSIVE PRODUCTION OF CARBON MONOXIDE (CO), A COLORLESS, ODOR- LESS, TOXIC GAS.

Carefully install this seven-piece log set into the firebox as shown in these instructions. All logs should fit onto corresponding pins and/or log stoppers. This will ensure a proper flame and safe combustion.

1.Place the ember strip in front of the burner as shown in Figure 9. It should be positioned all the way back (toward the sub-floor front flange).

Rear Log Stoppers

Ember

Strip

Figure 9

2.Place the largest log onto the rear log stoppers (see Figure 9). Ensure that the grooves on the bottom of the log aligns onto the corresponding places on the rear log stoppers. Push the log back so that it is against the back of the rear log stoppers (see Figure 10).

Rear

Log

Figure 10

3.Place the left front log onto the corre- sponding burner pin and sub-floor left tab as shown in Figure 11.

Left Front Log

Figure 11

4. Place the center log piece over the cor- responding pins next to the front left log as shown in figure 12.

Center

Log

Piece

Figure 12

5.Install the right front log onto the cor- responding burner pin and sub-floor right tab as shown in figure 13.

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

Right Front Log

Figure 13

6.Install the left top twig onto the correspond- ing pin on the rear log and align it with the indentation on the front left log as shown in figure 14.

Left Top

Twig

Figure 14

7. Install the center top twig onto the cor- responding pin on the rear log and align it with the indentation on front left log as shown in figure 15.

Center

Top Twig

Figure 15

8.Install the front right twig onto the cor- responding pin on the right front log. Align the twig with the indentation on the front right log as shown in figure 16.

Right

Front Twig

Figure 16

Image 8
Contents Pour Réduire AU Minimum LE Risque D’INCENDIE Table of Contents Control Compartment Access Lower Access DoorTables 3 and 4 show the units gas pressure requirements Operation and Care of Your ApplianceMaintenance Glass CleaningVerify Proper Operation After Servicing Models with Porcelain Enamel FinishMaintenance Schedule Maintenance Task Accomplishing Person ProcedureFront Glass Enclosure Panel, Removal and Installation Burner AdjustmentsReinstall Trivet Burner Flame AppearanceBurner Air Shutter Adjustment Air Shutter Adjustment GuidelinesLeft Top Twig Log PlacementRear Log Stoppers Do not Place Embers on TOP of the Burner Slots SIT Millivolt Appliance CheckoutProper Pilot Flame Appearance Small Area Paint Touch-upWiring Diagrams Warranty InformationReplacement Parts Product Reference InformationAccessory Components Brickaded Liner Kits Warming ShelvesTo Turn OFF GAS to Appliance This appliance has a pilot which must be lighted with aSIT Millivolt Gas Valve To PilotInstructions Dallumage Pour Fermer LE GAZ QUI Alimente L’APPAREILSymptom Possible Causes Corrective Action Replacement Parts List Gas ControlsCast Body Components Room Air Blower System Optional Kit 2021 29b 1314425 Reference Information Optional Warming Shelves Kit