LENNOX HEARTH PRODUCTS • MONTEBELLO®
GENERAL INFORMATION
The fireplace models covered in this manual are
All air for combustion is brought in from the outside, and exhaust gases are vented through the same
These appliances are designed to operate on natural or propane gas. The system is switch- able between standing and intermittent pilot modes. External electrical power is required to operate these units. If the system operates on line voltage, four (4) "AA" batteries (in receiver) can be used as a backup in case of a power outage.
These models come standard with a remotely modulated gas valve. The included transmitter remotely controls flame appearance and heat output (manual gas valve adjustment is not possible).
These appliances comply with National Safety Standards and are tested and listed by Intertek (Report No.
The installation must conform to local codes or, in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1/NFPA 54 - latest edition, or the Natural Gas and Propane Installa- tion Code,
Inputs and Efficiencies
Appliance BTU inputs are listed in Table 1A. Appliance efficiencies are listed in Table 1B.
Inputs
Gas Type (Fireplace Model) | Inputs (BTU/hr) |
Natural Gas | 40,000 to 60,000 |
Liquid Propane | 43,500 to 56,000 |
Table 1A
EFFICIENCIES
Gas Type (Fireplace Model) | AFUE | EnerGuide |
Natural Gas | 68% | 67% |
Liquid Propane | 70% | 67% |
Table 1B
Gas Fireplace Energy Efciency Rating
Based on CSA
Gas Pressure Requirements (All Models)
Tables 2 and 3 show the appliances’ gas pres- sure requirements.
Inlet Gas Supply Pressure (all models)
Fuel # | Minimum | Maximum | |
Natural Gas | 5.0" WC | 10.5" WC | |
(1.24 kPa) | (2.61 kPa) | ||
| |||
|
|
| |
Propane | 11.0" WC | 13.0" WC | |
(2.74 kPa) | (3.23 kPa) | ||
| |||
|
|
|
Table 2
Manifold Gas Supply Pressure (all models)
Fuel # | Low | High | |
|
|
| |
Natural | (Lo) 1.6" WC | (Hi) 3.5" WC | |
Gas | (0.4 kPa) | (0.87 kPa) | |
|
|
| |
Propane | (Lo) 6.3" WC | (Hi) 10.0" WC | |
(1.57 kPa) | (2.49 kPa) | ||
| |||
|
|
|
Table 3
Test gauge connections are provided on the front of the gas control valve, identified IN for the inlet and OUT for the manifold side (see Figure 1 on Page 8 ). The control valve has a 3/8" (10 mm) NPT thread inlet and outlet side of the valve.
These appliances must be isolated from the gas supply piping system (by closing their individual manual
These appliances and their individual
Orifice Sizes:
Sea Level to High Altitude (All Models)
These appliances are tested and approved for installations at elevations of
[*]in Table 4).
At the time of installation, it must be determined if the appliance needs to be derated. Contact your local gas supplier for deration requirements for your area.
Burner Orifice Sizes
Elevation 0–4500 feet (0–1372 meters)
Fireplace | Fireplace | |
Natural Gas |
| Propane |
Drill Size (inches) | Drill Size (inches) | |
|
| |
#32 (0.116")* | #52 (0.0635")* | |
[Orifice Cat. No. H8002] | [Orifice Cat. No. H8003] | |
|
|
|
Table 4 | *Standard size installed at factory. |
Deration
At higher elevations, the amount of BTU fuel value delivered must be reduced by either using gas that has been derated by the gas company or by changing the burner orifice to a smaller size as regulated by the local authorities having jurisdiction and by the (USA) National Fuel Gas Code NFPA 54/ANSI Z223.1 - latest edition or, in Canada, the
Burn-in Period
During the first few fires of this appliance there will be some odor due to the curing of the paint and burning off of lubricants used in the manufacturing process. Depending on your use, the
KEEP YOUR HOUSE WELL VENTILATED DURING THE CURING PROCESS. THE ODOR AND HAZE EMITTED DURING THE CURING PROCESS CAN BE QUITE NOTICEABLE AND MAY SET OFF A SMOKE DETECTOR.
NOTICE:
A white film may develop on the glass enclosure panel during the first few fires as part of the
The first few times you use the fireplace, clean the glass after each use (AFTER THE GLASS HAS COMPLETELY COOLED); otherwise, the white film will bake onto the glass and become difficult to remove.
See glass cleaning instructions on
Page 9.
7
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.