Lennox Hearth LBR-4324-H, LBC-4324-H, LBC-3824-H, LBR-3824-H Installation Components

Page 19

Combustible materials may project beyond the sides of the fireplace opening as long as they are kept within the shaded area, as illustrated in Figure 49 for LBR models and Figure 50 for LBC models.

Combustible Materials

Allowed in Shaded

Area

18"

1"

(457mm)

(25mm)

 

45˚

18" (457mm) Minimum Distance to Protected Side Wall

LBR Models

Figure 49

Combustible Materials

Allowed in Shaded

Area

4-17/32"

1/2"

(115mm)

(13mm)

 

30˚

12" (305mm) Minimum Distance to Protected Side Wall

LBC Models

Figure 50

Model

Catalog Number

Weight

LBR-3824

11M70

225 lbs.

LBC-3824

11M72

225 lbs.

LBR-3824-H

11M74

225 lbs.

LBC-3824-H

11M76

225 lbs

LBR-4324

11M71

250 lbs.

LBC-4324

11M73

250 lbs.

LBR-4324-H

11M75

250 lbs.

LBC-4324-H

11M77

250 lbs.

INSTALLATION COMPONENTS

The following items are available for use in the installation of this appliance.

Outside Combustion Air Kits

 

(with duct)

81L87

FOAK

(without duct)

81L88

FOAK-LD

 

 

 

Storm Collar

63L59

FSC

Locking Band

63L60

FLB

Firestop Spacer (30° )

63L37

F10FS30-2

 

 

 

Firestop Spacer (Flat)

63L36

F10FS-2

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

Chimney Section

63L16

FTF10-12

 

63L17

FTF10-18

 

63L18

FTF10-36

Canadian

62L94

FTF10-18C

Outside Chimney

62L95

FTF10-36C

 

63L40

F10F6

Flashing

63L41

F10F12

 

 

 

Chase Termination

 

 

(Square)

63L49

FTF10-CT1

Chase Termination

 

 

(Round)

63L55

FTF10-CTDTM

Stabilizer

63L26

FTF10-S4

19

Image 19
Contents WH Report No -915173A Retain These Instructions For Future ReferenceTable of Contents Clearances and Height Requirements Typical InstallationPrecautions IntroductionLocation of Fireplace Assembly OutlineChimney Height Chase EnclosureClearances Installing the FireplaceAssembly Steps PRE-INSTALLATION NotesTop View Fireplace SpecificationsFront LBC Shown Left Side Right SideFTF10 Framing SpecificationsInstalling the Chimney System For Canadian Installations, Proceed with Steps 6 throughChimney 30 Offset Through Floor 8d nails when completely installedOr Ceiling For Canada Only12 to 12/12 Roof Pitch Model Flat to 6/12Multiple Terminations TEN Foot Rule SummaryFTF10 Chimney Component Calculations FTF10-CT2 Termination Special Offset InstructionsOffset Calculations FTF10-CT1 TerminationInches FTF10 Vertical Elevation ChartNumber Of FTF10 Chimney OnlyInstalling Offsets FTF10 Offset Elevation ChartFirst, review the Offset Elevation Chart and for reference Optional Equipment Considerations Fireplace Finishes Cold Climate InsulationOpening Width Hearth Extension DimensionsMethods of Determining Hearth Extension and Wall Shield TL = minimum thickness of listed materialValue = 1/k = r x thickness of material used Finish to Your TasteRM = rM x TS = 0.05 x 3/4 = There are a wide variety of finished looks forInstallation Components 850,003M REV. G 01/2010 Installation ComponentsOrange, CA