Trane TWA075A, TWE200B, TWA200B, TWE050A manual Outdoor Heating Capacity Btu/1000 At

Page 20

Performance

Data(System)

Table PD-9 — Gross Heating Capacities (MBh)

TWA075A Heat Pump with TWE075A Air Handler At 2500 CFM (I-P)

Outdoor

Heating Capacity (Btu/1000) At

 

Total Power in Kilowatts At

 

Temperature

Indicated Indoor Dry BulbTemperature

Indicated Indoor Dry BulbTemperature

(°F)

60

70

75

80

60

70

75

80

-18

33.0

28.7

27.1

25.9

5.6

5.7

5.9

6.0

-13

34.1

30.4

29.0

27.9

5.5

5.7

5.9

6.1

-8

35.6

32.4

31.2

30.3

5.5

5.8

5.9

6.2

-3

37.5

34.8

33.9

33.2

5.5

5.8

6.0

6.3

2

40.0

37.7

37.0

36.4

5.5

5.9

6.1

6.4

7

42.8

41.1

40.5

40.1

5.6

6.0

6.2

6.5

12

46.2

44.9

44.4

44.2

5.6

6.1

6.3

6.6

17

50.0

49.1

48.7

48.5

5.7

6.2

6.5

6.8

22

54.4

53.6

53.4

53.2

5.8

6.3

6.6

7.0

27

59.2

58.6

58.4

58.2

5.9

6.4

6.8

7.1

32

64.5

63.9

63.7

63.5

6.0

6.6

6.9

7.3

37

69.9

69.4

69.1

68.8

6.1

6.7

7.1

7.5

42

75.7

75.1

74.7

74.3

6.2

6.9

7.2

7.6

47

81.8

81.1

80.6

80.1

6.4

7.0

7.4

7.8

52

88.3

87.4

86.8

86.2

6.5

7.2

7.6

8.0

57

95.1

93.9

93.2

92.4

6.7

7.4

7.7

8.1

62

102.0

100.6

99.8

98.9

6.8

7.5

7.9

8.3

67

109.0

107.4

106.5

105.5

7.0

7.7

8.1

8.5

72

116.3

114.5

113.4

112.3

7.2

7.9

8.2

8.6

Table PD-9 — Gross Heating Capacities (kW)

TWA075A Heat Pump with TWE075A Air Handler At 4247 m3/h (SI)

Outdoor

 

Heating Capacity (kW) At

 

 

Total Power in Kilowatts At

 

Temperature

Indicated Indoor Dry BulbTemperature

Indicated Indoor Dry BulbTemperature

(°C)

15.6

21.1

23.9

26.7

15.6

21.1

23.9

26.7

-27.8

9.7

8.4

7.9

7.6

5.5

6.0

6.2

6.5

-25.0

10.0

8.9

8.5

8.2

5.6

6.1

6.3

6.6

-22.2

10.4

9.5

9.1

8.9

5.7

6.2

6.5

6.7

-19.4

11.0

10.2

9.9

9.7

5.8

6.3

6.6

6.9

-16.7

11.7

11.0

10.8

10.7

5.9

6.5

6.7

7.0

-13.9

12.5

12.0

11.9

11.7

6.0

6.6

6.9

7.2

-11.1

13.5

13.1

13.0

12.9

6.2

6.7

7.0

7.4

-8.3

14.7

14.4

14.3

14.2

6.3

6.9

7.2

7.5

-5.6

15.9

15.7

15.6

15.6

6.5

7.0

7.4

7.7

-2.8

17.3

17.2

17.1

17.0

6.6

7.2

7.5

7.9

0.0

18.9

18.7

18.7

18.6

6.8

7.4

7.7

8.1

2.8

20.5

20.3

20.2

20.1

6.9

7.6

7.9

8.3

5.6

22.2

22.0

21.9

21.8

7.1

7.8

8.1

8.5

8.3

24.0

23.7

23.6

23.4

7.3

8.0

8.4

8.8

11.1

25.9

25.6

25.4

25.2

7.5

8.2

8.6

9.0

13.9

27.8

27.5

27.3

27.1

7.7

8.4

8.8

9.2

16.7

29.9

29.5

29.2

29.0

7.9

8.7

9.1

9.5

19.4

31.9

31.5

31.2

30.9

8.1

8.9

9.3

9.8

22.2

34.1

33.5

33.2

32.9

8.4

9.2

9.6

10.0

Correction Factors - Other Airflows

 

Airflow = 2500 cfm (4247 m3/h)

(Table Value x Correction Factor = Value at new airflow)

Heating Capacity (High Temp.) = 81,000 (23.72)

 

 

 

Heating Capacity (Low Temp.) = 49,000 (14.35)

Airflow

2250 cfm

2750 cfm

Compressor Power (High Temp) = 5.67 kW

 

3822 m3/h

4672 m3/h

Compressor Power (Low Temp) = 4.80 kW

Heating Capacity

x0.99

x1.01

Coeff. Of Perf. (High Temp) = 3.4

Compressor kW

x1.02

x0.98

Coeff. Of Perf. (Low Temp) = 2.3

 

 

 

Outdoor Fan Power = 550 watts

Values at ARI Rating Conditions of:

 

Indoor Fan Power = 800 watts

70F (21.1C) and 47/43F (8.3/6.1C)(High Temp.Cond.)

 

70F (21.1C) and 17/15F (-8.3/-9.4C)(Low Temp. Cond)

Note:

 

 

 

1. Rated with 25 feet of 1-3/8" suction and 1/2" liquid line.

20

SSP-PRC002-EN

Image 20
Contents Split System Heat Pumps Manufacturing Control Designing the DetailsStandardized Cabinets FiltersContents Features and Benefits Low Ambient Cooling OperationOdyssey a Complete Split System Blower Rotation Application ConsiderationsClearance Requirements Selection Procedure Cooling CapacityHeating Capacity Air Delivery SelectionAir Handler Model Nomenclature Model Number DescriptionSplit System Heat Pump Model Nomenclature Table GD-1 General Data Heat Pumps General DataHeat Pumps Condensing Unit Power kW Table GD-2 General Data Heat PumpsCondensing Unit Only 2, Btu kW Number Type 3D Scroll No. Motors Motor HP Motor RPM, kWTable GD-3 General Data Air HandlersTable GD-3 General Data Air Handlers Performance DataSystem125.2 99.3109.5 120.5105 115 Dry EnteringWet Bulb F4500 119.6 99.3115 105 Enter Dry 161.9216.2 223.9DataTWA075A TWA100A Heat Pump Only SI ODTemp Suction ReferenceTemperature CDataTWA100A DataTWA155B TWA155B Heat Pump Only SIDataTWA200B TWA200B Heat Pump Only SIOutdoor Heating Capacity Btu/1000 At OutdoorTemperature Indicated Indoor Dry BulbTemperature Outdoor Heating Capacity BTUH/1000 At15.6 20.1DataSystem Performance Data Air HandlerTable PD-13 Evaporator Fan Performance TWE050A I-P Table PD-13- Evaporator Fan Performance TWE050A SITable PD-15 Evaporator Fan Performance TWE075A I-P Table PD-15Table PD-15 Evaporator Fan Performance TWE075A SI Table PD-16 Blower Speeds TWE075ATable PD 18 Blower Speeds TWE100A,TWE100B Table PD-17 Evaporator Fan Performance TWE100A, TWE100B I-PTable PD-17 Table PD-19 Evaporator Fan Performance TWE155B I-P Table PD-19 Evaporator Fan Performance TWE155B SITable PD-20- Blower Speeds TWE155B KW RPMTable PD-21- Evaporator Fan Performance TWE200B I-P Table PD-21Table PD-21- Evaporator Fan Performance TWE200B SI Table PD-22 Blower Speeds TWE200BUnit Louver Angle Deflection Position Model No Straight 1400TWE050 1800 2200Table PD-25 Auxiliary Electric Heat Capacity Air Handler Table ED-1- Electrical Characteristics Motors Air Handler Table ED-2 UnitWiring Air HandlerTable ED-4 UnitWiring Heat Pumps Electrical Data34.62 Heater17.31 Jobsite Connections TWA050/TWE050TWA075A/TWE075A 2TWA075A/TWE155BTypical Wiring Heat Pump Single CompressorHeat Pump Heat Pump Dual Compressors Typical Air Handler Air HandlerDimensional Figure DD-1 TWA075 Heat PumpDimensional Data Figure DD-2 10TonTWA100A Heat PumpFigure DD-3 TWA155B Heat Pump Figure DD-4 TWA200B Heat Pump Figure DD-5 TWE050AAir Handlers Figure DD-6 -TWE075A Air Handler Figure DD-7-TWE100A Air Handler Figure DD-8-TWE100B Air Handler 878 Table DD-1 Air Handler Dimensions in. mm905 Figure DD-10- TWE155B Air Handler Figure DD-11 -TWE200B Air Handler Table DD-2 Air Handler Dimensions in. mm Table DD-2- Air Handler Dimensions in. mmDataAccessories Mechanical Specifications Evaporator Coil Evaporator FanPage Page Trane Literature Order Number

TWA200B, TWA075A, TWE200B, TWE050A specifications

Trane has a long-standing reputation for manufacturing high-efficiency heating, ventilation, and air conditioning (HVAC) systems. Among their impressive lineup are the Trane TWA200B, TWE050A, TWA075A, and TWE200B models, each designed with advanced technologies that cater to various residential and commercial needs.

The Trane TWA200B is a powerful 2-ton air handler equipped with a variable-speed blower that enhances energy efficiency and provides consistent airflow. With a compact design, it fits well in tight spaces while delivering superior indoor comfort. One of its notable features is its compatibility with Trane's ComfortLink II Zoning System, allowing for customized temperature control in different zones of a building. This model is optimized for use with high-efficiency heat pumps and has enhanced filtration options that improve indoor air quality by trapping dust, pollen, and other allergens.

The TWE050A is a 5-ton packaged air conditioning unit that integrates both cooling and heating capabilities. This model is particularly praised for its high SEER (Seasonal Energy Efficiency Ratio) rating, which indicates superior energy efficiency and reduced operational costs. The TWE050A utilizes Trane's proprietary Spine Fin coil technology, which maximizes surface area for better heat exchange and overall efficiency. Its durable construction ensures long-lasting performance in various weather conditions, making it ideal for both residential and light commercial applications.

The TWA075A is a versatile 7.5-ton air handler designed for larger spaces. It features a robust construction and is equipped with a multi-speed blower that can be adjusted to meet specific airflow requirements, ensuring optimal comfort. This model is notable for its sound attenuation features, which minimize operational noise, making it suitable for quiet environments. Additionally, the TWA075A supports advanced thermostat compatibility, enabling users to maintain precise control over indoor temperatures.

Finally, the TWE200B stands out as a 20-ton packaged rooftop unit, making it an excellent choice for extensive commercial applications. Its advanced compressor technology ensures effective cooling and heating while maintaining high energy efficiency. The TWE200B includes enhanced connectivity options, allowing for remote monitoring and control through smart devices. This model also incorporates Trane's Integrated Comfort System, which streamlines operation and simplifies maintenance tasks.

Overall, the Trane TWA200B, TWE050A, TWA075A, and TWE200B models embody the company's commitment to quality, innovation, and energy efficiency, making them excellent choices for a wide array of HVAC applications.