Trane TWE200B, TWA075A, TWA200B, TWE050A manual Temperature

Page 21

Performance

Data(System)

Table PD-10 — Gross Heating Capacities (MBh)

TWA100A Heat Pump with TWE100A Air Handler At 3325 CFM (I-P)

Outdoor

Heating Capacity (Btu/1000) At

 

Total Power in Kilowatts At

 

Temperature

Indicated Indoor Dry BulbTemperature

Indicated Indoor Dry BulbTemperature

(°F)

60

70

75

80

60

70

75

80

-18

20.4

37.3

41.2

43.6

5.7

7.3

7.9

8.5

-13

31.4

41.8

44.6

46.4

6.2

7.5

8.0

8.6

-8

39.0

46.3

48.4

49.7

6.5

7.6

8.1

8.6

-3

45.5

50.8

52.4

53.3

6.8

7.8

8.2

8.7

2

51.8

55.6

56.7

57.3

7.0

7.9

8.4

8.8

7

57.9

60.6

61.3

61.6

7.2

8.0

8.5

9.0

12

64.1

65.8

66.2

66.3

7.3

8.2

8.6

9.1

17

70.4

71.3

71.4

71.3

7.5

8.3

8.7

9.2

22

76.9

77.1

77.0

76.7

7.6

8.4

8.9

9.4

27

83.6

83.3

82.9

82.5

7.8

8.6

9.0

9.5

32

90.7

89.7

89.2

88.7

7.9

8.8

9.2

9.7

37

97.6

96.2

95.5

94.9

8.1

8.9

9.4

9.9

42

104.6

102.9

102.1

101.4

8.2

9.1

9.6

10.1

47

112.0

109.9

109.0

108.2

8.4

9.3

9.7

10.3

52

119.5

117.2

116.2

115.2

8.6

9.5

10.0

10.5

57

127.1

124.6

123.5

122.5

8.8

9.7

10.2

10.7

62

134.8

132.1

130.8

129.7

9.0

9.9

10.4

11.0

67

142.6

139.7

138.3

137.2

9.2

10.1

10.7

11.2

72

150.7

147.5

146.1

144.8

9.4

10.4

10.9

11.5

Table PD-10 — Gross Heating Capacities (kW)

TWA100A Heat Pump with TWE100A Air Handler At 5649 m3/h (SI)

Outdoor

 

Heating Capacity (kW) At

 

 

Total Power in Kilowatts At

 

Temperature

Indicated Indoor Dry BulbTemperature

Indicated Indoor Dry BulbTemperature

(°C)

15.6

21.1

23.9

26.7

15.6

21.1

23.9

26.7

-27.8

6.0

10.9

12.1

12.8

5.5

6.0

6.2

6.5

-25.0

9.2

12.2

13.1

13.6

5.6

6.1

6.3

6.6

-22.2

11.4

13.5

14.2

14.6

5.7

6.2

6.5

6.7

-19.4

13.3

14.9

15.3

15.6

5.8

6.3

6.6

6.9

-16.7

15.2

16.3

16.6

16.8

5.9

6.5

6.7

7.0

-13.9

17.0

17.7

17.9

18.0

6.0

6.6

6.9

7.2

-11.1

18.8

19.3

19.4

19.4

6.2

6.7

7.0

7.4

-8.3

20.6

20.9

20.9

20.9

6.3

6.9

7.2

7.5

-5.6

22.5

22.6

22.5

22.5

6.5

7.0

7.4

7.7

-2.8

24.5

24.4

24.3

24.1

6.6

7.2

7.5

7.9

0.0

26.5

26.3

26.1

26.0

6.8

7.4

7.7

8.1

2.8

28.6

28.2

28.0

27.8

6.9

7.6

7.9

8.3

5.6

30.6

30.1

29.9

29.7

7.1

7.8

8.1

8.5

8.3

32.8

32.2

31.9

31.7

7.3

8.0

8.4

8.8

11.1

35.0

34.3

34.0

33.7

7.5

8.2

8.6

9.0

13.9

37.2

36.5

36.2

35.9

7.7

8.4

8.8

9.2

16.7

39.5

38.7

38.3

38.0

7.9

8.7

9.1

9.5

19.4

41.7

40.9

40.5

40.2

8.1

8.9

9.3

9.8

22.2

44.1

43.2

42.8

42.4

8.4

9.2

9.6

10.0

Correction Factors - Other Airflows

 

Airflow = 3325 cfm (5649 m3/h)

(Table Value x Correction Factor = Value at new airflow)

Heating Capacity (High Temp.) = 110,000 (32.21)

 

 

 

Heating Capacity (Low Temp.) = 71,000 (20.79)

Airflow

3000 cfm

3675 cfm

Compressor Power (High Temp) = 7.59 kW

 

5097 m3/h

6243 m3/h

Compressor Power (Low Temp) = 6.60 kW

Heating Capacity

x0.99

x1.01

Coeff. Of Perf. (High Temp) = 3.4

Compressor kW

x1.02

x0.98

Coeff. Of Perf. (Low Temp) = 2.4

 

 

 

Outdoor Fan Power = 615 watts

Values at ARI Rating Conditions of:

 

Indoor Fan Power = 1,030 watts

70F (21.1C) and 47/43F (8.3/6.1C)(High Temp.Cond.)

 

70F (21.1C) and 17/15F (-8.3/-9.4C)(Low Temp. Cond)

Note:

 

 

 

1. Rated with 25 feet of 1-3/8" suction and 1/2" liquid line.

SSP-PRC002-EN

21

Image 21
Contents Split System Heat Pumps Designing the Details Manufacturing ControlStandardized Cabinets FiltersContents Low Ambient Cooling Operation Features and BenefitsOdyssey a Complete Split System Application Considerations Clearance RequirementsBlower Rotation Cooling Capacity Selection ProcedureHeating Capacity Air Delivery SelectionModel Number Description Split System Heat Pump Model NomenclatureAir Handler Model Nomenclature General Data Heat PumpsTable GD-1 General Data Heat Pumps Table GD-2 General Data Heat Pumps Condensing Unit Power kWCondensing Unit Only 2, Btu kW Number Type 3D Scroll No. Motors Motor HP Motor RPM, kWAir Handlers Table GD-3 General Data Air HandlersTable GD-3 General Data DataSystem Performance99.3 125.2109.5 120.5Dry EnteringWet Bulb F 105 1154500 119.6 99.3161.9 115 105 Enter Dry216.2 223.9DataTWA075A ODTemp Suction ReferenceTemperature C DataTWA100ATWA100A Heat Pump Only SI TWA155B Heat Pump Only SI DataTWA155BTWA200B Heat Pump Only SI DataTWA200BOutdoor Outdoor Heating Capacity Btu/1000 AtTemperature Outdoor Heating Capacity BTUH/1000 At Indicated Indoor Dry BulbTemperature15.6 20.1DataSystem Air Handler Performance DataTable PD-13 Evaporator Fan Performance TWE050A I-P Table PD-13- Evaporator Fan Performance TWE050A SITable PD-15 Table PD-15 Evaporator Fan Performance TWE075A I-PTable PD-15 Evaporator Fan Performance TWE075A SI Table PD-16 Blower Speeds TWE075ATable PD-17 Evaporator Fan Performance TWE100A, TWE100B I-P Table PD-17Table PD 18 Blower Speeds TWE100A,TWE100B Table PD-19 Evaporator Fan Performance TWE155B SI Table PD-19 Evaporator Fan Performance TWE155B I-PTable PD-20- Blower Speeds TWE155B KW RPMTable PD-21 Table PD-21- Evaporator Fan Performance TWE200B I-PTable PD-21- Evaporator Fan Performance TWE200B SI Table PD-22 Blower Speeds TWE200BStraight 1400 Unit Louver Angle Deflection Position Model NoTWE050 1800 2200Table PD-25 Auxiliary Electric Heat Capacity Air Handler Table ED-2 UnitWiring Air Handler Table ED-1- Electrical Characteristics Motors Air HandlerTable ED-4 UnitWiring Heat Pumps Electrical DataHeater 17.3134.62 TWA050/TWE050 Jobsite ConnectionsTWA075A/TWE075A 2TWA075A/TWE155BHeat Pump Single Compressor Typical WiringHeat Pump Heat Pump Dual Compressors Typical Air Handler Air HandlerFigure DD-1 TWA075 Heat Pump DimensionalFigure DD-2 10TonTWA100A Heat Pump Dimensional DataFigure DD-3 TWA155B Heat Pump Figure DD-4 TWA200B Heat Pump Figure DD-5 TWE050AAir Handlers Figure DD-6 -TWE075A Air Handler Figure DD-7-TWE100A Air Handler Figure DD-8-TWE100B Air Handler Table DD-1 Air Handler Dimensions in. mm 905878 Figure DD-10- TWE155B Air Handler Figure DD-11 -TWE200B Air Handler Table DD-2- Air Handler Dimensions in. mm Table DD-2 Air Handler Dimensions in. mmDataAccessories Mechanical Specifications Evaporator Fan Evaporator CoilPage Page Literature Order Number Trane

TWA200B, TWA075A, TWE200B, TWE050A specifications

Trane has a long-standing reputation for manufacturing high-efficiency heating, ventilation, and air conditioning (HVAC) systems. Among their impressive lineup are the Trane TWA200B, TWE050A, TWA075A, and TWE200B models, each designed with advanced technologies that cater to various residential and commercial needs.

The Trane TWA200B is a powerful 2-ton air handler equipped with a variable-speed blower that enhances energy efficiency and provides consistent airflow. With a compact design, it fits well in tight spaces while delivering superior indoor comfort. One of its notable features is its compatibility with Trane's ComfortLink II Zoning System, allowing for customized temperature control in different zones of a building. This model is optimized for use with high-efficiency heat pumps and has enhanced filtration options that improve indoor air quality by trapping dust, pollen, and other allergens.

The TWE050A is a 5-ton packaged air conditioning unit that integrates both cooling and heating capabilities. This model is particularly praised for its high SEER (Seasonal Energy Efficiency Ratio) rating, which indicates superior energy efficiency and reduced operational costs. The TWE050A utilizes Trane's proprietary Spine Fin coil technology, which maximizes surface area for better heat exchange and overall efficiency. Its durable construction ensures long-lasting performance in various weather conditions, making it ideal for both residential and light commercial applications.

The TWA075A is a versatile 7.5-ton air handler designed for larger spaces. It features a robust construction and is equipped with a multi-speed blower that can be adjusted to meet specific airflow requirements, ensuring optimal comfort. This model is notable for its sound attenuation features, which minimize operational noise, making it suitable for quiet environments. Additionally, the TWA075A supports advanced thermostat compatibility, enabling users to maintain precise control over indoor temperatures.

Finally, the TWE200B stands out as a 20-ton packaged rooftop unit, making it an excellent choice for extensive commercial applications. Its advanced compressor technology ensures effective cooling and heating while maintaining high energy efficiency. The TWE200B includes enhanced connectivity options, allowing for remote monitoring and control through smart devices. This model also incorporates Trane's Integrated Comfort System, which streamlines operation and simplifies maintenance tasks.

Overall, the Trane TWA200B, TWE050A, TWA075A, and TWE200B models embody the company's commitment to quality, innovation, and energy efficiency, making them excellent choices for a wide array of HVAC applications.