Honeywell XG1000 manual Remote account username and password, Black wire to Pin Red wire to Pin

Page 2

INSTALLATION CHECKLIST ///

XG1000 Controller and a Honeywell Bridge

6160 Alpha panel as a debugging tool

Confirm address 22 is open and configured as a keypad device.

Please note that if 22 is already is use, the existing keypad will need to be moved to a different address

Remote account username and password

INSTALL & VALIDATE XG1000 CONTROLLER ///

1.Locate the customer’s external internet connection and the in-home router. Find one unused LAN RJ-45 port on the router. Then, use an Ethernet cable to connect the LAN RJ45 port on the XG1000 Controller to the unused LAN RJ45 port on the router.

XG1OOO CONTROLLER

1

2

3

4

 

 

 

 

 

INTERNET

 

LAN

 

WAN

LAN

 

ROUTER

DSL/CABLE MODEM

 

(NOT INCLUDED)

(NOT INCLUDED)

2.Connect XG1000 Controller to power and verify the following:

The XG1000 ‘X’ power LED is lighted BLUE

If the power LED is not lighted, please re-check all power connections (see Troubleshooting Section)

The XG1000 LAN/Link LED is lighted GREEN

If the LAN/Link LED does not light check the Ethernet connection and/or try using a different Ethernet cable (see Troubleshooting Section)

3.Wait up to 3 minutes for the XG1000 Controller to initialize.

4.Check and confirm LED marked ‘REM’ is solid GREEN (REM LED is the health indicator for remote access).

 

DEV

 

 

LAN

 

 

 

 

 

 

 

 

 

 

ACT

STAT

REM

ACT

LINK

REMOTE CONNECTIVITY

LAN LINK

POWER INDICATOR

HONEYWELL BRIDGE INSTALLATION PROCEDURE ///

1.Connect the Honeywell Bridge to the Honeywell Panel (or the keypad if possible)

The Bridge connects just like an additional keypad (SafeWatch Pro 3000 terminals noted). Please power down the Honeywell Panel prior to beginning this process:

Black wire to Pin 4

Red wire to Pin 5

 

 

HONEYWELL

Green wire to Pin 6

 

 

BRIDGE

 

 

 

Yellow wire to Pin 7

 

 

 

 

SAFEWATCH PRO 3000

 

CONTROL TERMINAL STRIP

 

AUX.

AUX.

DATA

DATA

 

+

IN

OUT

 

4

5

6

7

 

TO KEYPAD BLK WIRE

 

 

BRIDGE YEL WIRE

 

TO KEYPAD RED WIRE

 

 

BRIDGE GRN WIRE

 

TO KEYPAD GRN WIRE

 

 

BRIDGE RED WIRE

 

TO KEYPAD YEL WIRE

 

 

BRIDGE BLK WIRE

NOTE: The existing keypad will remain connected. Mount the Bridge device near the alarm panel away from large metal objects. If necessary, you can extend the length of the wire using four conductor cable and wire nuts. For best results the bridge device should be mounted as high as possible, preferably at least 6 feet above the floor.

2.Re-connect power to the Honeywell Panel.

3.The LED on the Honeywell Bridge should light up and display RED – If the LED does not light up, the Bridge is not receiving power, please check all connections (see Troubleshooting Section).

If the LED changes from solid GREEN to solid RED within the first 60 seconds after applying power, and remains solid RED, the Controller and the Bridge may be having difficulty communicating. Please perform the Range Test described in the Troubleshooting Section of this manual.

4.Go to existing alarm keypad. Disarm the alarm system, establish access to alarm system via the “Installer Code” (may need to re-power unit and use ‘#*’ to set an installer code).

5.Connect a 6160 ALPHA KEYPAD if existing keypad is not alpha. From the keypad enable

the keypad address 22 in the alarm panel for use by the Honeywell Bridge (for the SafeWatch Pro 3000, enter ‘[ 1, 0 ]’ in location ‘*195’).

I

2

Image 2
Contents MyRemoteManager Green wire to Pin Remote account username and passwordBlack wire to Pin Red wire to Pin Re-connect power to the Honeywell PanelCompleting the Installation Push the ‘RANGE TEST’ button Click on the ‘APPLY CHANGES’ button to save your settingsWill automatically go to Arm Stay mode XG1000