Honeywell F111 Series 2 Specifications, Ordering Information, Most Gases, Installation Weight

Page 2

F111 (SERIES 1,2) IN CEILING MEDIA AIR CLEANER

SPECIFICATIONS

IMPORTANT

The specifications given in this publication do not include normal manufacturing tolerances. Therefore, this unit may not exactly match the listed specifica- tions. Also, this product is tested and calibrated under closely controlled conditions, and some minor differences in performance can be expected if those conditions are changed.

Models: Refer to Table 1 for model descriptions.

Color: White or black cabinet and cover.

Blower/Motor: Single speed direct drive forward curve.

Dimensions: See Fig. 1 for dimensions.

Table 1. F111 (Series 1,2) Description.

 

 

 

 

Efficiency

 

 

 

 

 

 

 

V.O.C./Odor

Gas, V.O.C. and

Air Volume

 

 

 

 

Particulates at

(Most Gases/

 

 

 

 

0.3 Micron

Odors First Pass

Odor Control

in cfm

Model

 

Voltage

(DOP Test)

Average)

Modules (2)

(m3/hr)

F111A1063 (11006)

120

Vac, 60

Hz, 1PHS, 6.5A

99.97% HEPA

N/A

N/A

1000 (1700)

 

 

 

 

 

 

 

 

F111A1253(11025)

120

Vac, 60

Hz, 1PHS, 6.5A

95% ASHRAEa

CPZ™ availablea

b

1230/1125c

F111A2007

208/230 Vac, 50/60 Hz, 3.7A

99.97% HEPA

N/A

N/A

1000 (1700)

 

 

 

 

 

 

 

 

F111C1012 (11001)

120

Vac, 60

Hz, 6.5A

95%

85%

CPZ™ modules

1000 (1700)

 

 

 

 

 

 

 

 

F111C1038 (11003)

277

Vac, 60

Hz, 2.8A

95%

85%

CPZ™ modules

1000 (1700)

 

 

 

 

 

 

F111C1053 (11005)

208/230 Vac, 50/60 Hz, 3.7A

95%

85%

CPZ™ modules

1000 (1700)

 

 

 

 

 

 

 

 

N/A = not applicable.

 

 

 

 

 

 

 

aPurchase filters separately. bDepends on filters used.

c1230 or 1125 when used with CPZ modules.

TOP VIEW

3/8 X 16 INTERNAL THREAD (4)

Installation Weight:

Approximately 115 lb to 155 lb (kg) depending on the filter con- figuration. Refer to Table 2.

48 (1219)

46-3/4 (1187)

POWER CONNECTION

POINT

17-1/4

(438)

4-1/2

(114)

24 (610)

22-1/2 (572)

CEILING

LINE

M11996A

Table 2. Sorbent Module Weight.

Media

Weight in lb (kg)

CPZ™ module

43 (20)

 

 

Sound Level at 3.3 ft (1m):

Low speed: 53 dBA (when using optional variable speed switch).

High speed: 61 dBA.

Grille Type: Perforated metal.

Mounting: Recesses into opening on the ceiling.

Fig. 1. Approximate Dimensions of F111 in in. (mm)

Ordering Information

If you have additional questions, need further information, or would like to comment on our products or services, please write or phone:

1.Your local Honeywell Commercial Air Products Distributor.

2.Air-Pure Systems. 16873 Fish Point Rd. SE Prior Lake, MN 55372 www.cleanairfacility.com Phone: (800) 998-1919 Fax: (800) 221-3248

68-0198EF-4

2

Image 2
Contents Application FeaturesContents Ordering Information SpecificationsInstallation Weight Most GasesFor Use In Fire Resistance Rated Construction Planning the InstallationChoose Location Installation When Installing this Product…Removing /Replacing the Lid Lid AssemblyOpening/Closing the Lid Prefilter ServiceOperation Particle FilterCPZ Adsorbent Module Module weighs about 26 lb 12 kg and can be hard to handleParts List Not shown in FigM11995E Limited TWO-YEAR Warranty Air-Pure Systems, Inc

F111 Series 2, F111 Series 1 specifications

The Honeywell F111 Series 1 and Series 2 are advanced control systems designed for various aerospace applications, instrumental in enhancing operational efficiency and reliability in flight management. Renowned for their pioneering technologies, these systems are created to meet the growing demands of modern aviation.

The F111 Series 1 features a robust architecture that integrates diverse avionics, ensuring compatibility and interoperability with existing aircraft systems. This series employs state-of-the-art signal processing techniques, allowing for enhanced data interpretation from onboard sensors. Pilots benefit from real-time information displays, granting them better situational awareness during flights. The control algorithms that govern autopilot functions are precisely tuned, yielding smoother transitions during manual and automatic flying.

On the other hand, the F111 Series 2 builds upon its predecessor's foundation, introducing several enhancements. One of its key features is an upgraded user interface, which simplifies pilot interaction and reduces cognitive workload. The Series 2 includes advanced predictive maintenance capabilities, offering real-time diagnostics that help anticipate issues before they escalate, significantly reducing downtime and maintenance costs.

Both series utilize cutting-edge technologies such as digital signal processors and integrated circuit designs, which improve reliability while minimizing weight—an essential factor in aircraft design. The systems are also designed for ruggedness, ensuring they can withstand the harsh environments encountered in aviation. Additionally, they incorporate safety measures like redundancy protocols and fail-safe mechanisms to enhance flight security.

The communication capabilities of both F111 series are noteworthy; they are equipped with modern data links that facilitate seamless connectivity with ground control and other aircraft. This feature enhances coordination in cooperative operations, making them ideal for military and commercial applications alike.

In summary, the Honeywell F111 Series 1 and Series 2 represent a significant advancement in avionics technology. With their intelligent design, robust features, and focus on safety and efficiency, these systems are at the forefront of modern aviation, ensuring pilots have the tools they need for successful flight operations while minimizing operational risks. Their continual evolution reflects the commitment to meeting the dynamic challenges of the aerospace industry.