Honeywell 16 Plus manual Star ¸ Key Features, ¸ #

Page 12

Power LED: The green power LED remains lit whenever the system is connected to the a.c. mains power supply and a charged stand-by battery. A mains power failure is indicated by the LED flashing slowly. A fuse or battery failure is indicated by the LED flashing quickly.

Your User Code: is a four digit personal identification number which identifies you to, and allows you to operate, the system.

Note: Entry of an invalid code will cause the keypad to display the message INVALID CODE. Entry of six consecutive invalid codes will cause a ten minute keypad lockout during which the keypad horns activate and the keypad displays the message ALARM IS ACTIVE. No further code entries will be recognised during the lockout period.

Star (¸) Key Features

The star key is used as a shift key, when combined with other keys it provides additional system features. To toggle the enable status of the Star key features enter either the manager code (User 14) at the keypad and then hold down the Star (¸) key and press the esc key; after a second the keypad displays ¸ ENABLE ON, or, ¸ ENABLE OFF; release both keys.

Key Combination

Star Feature

 

 

¸1

Changes keypad buzzer volume.

 

 

¸2

Activates PA alarm.

 

 

Mgr. Code + ¸3

Toggles On/Off to authorise Galaxy

 

Gold connection.

 

 

¸4

Toggles keypad backlighting On/Off.

 

 

¸5

Activates Medical alarm.

 

 

Code + ¸6

Prints the entire system details.

 

 

Code + ¸7

Prints the entire event log.

 

 

¸8

Activates the Fire alarm.

 

 

¸9

Initiates the Engineer's Test.

¸#

Indicates zone statuses.

 

 

Mgr. Code + ¸ent

Activates the Galaxy Gold Call Back.

Mgr. Code + ¸esc

Toggles ¸ key featues On/Off.

 

 

Galaxy 16 plus only.

 

Table 1: Star Key Features.

Note: The Star mode must be enabled for the Star features to operate.

2

Image 12
Contents Galaxy 16 and 16 plus Page Table of Contents Option 9 Log Introduction Page Quick Operation Guide Viii Glossary of Terms Page Keypad Information Star ¸ Key Features ¸ #Setting and Unsetting the System Setting the SystemBefore Setting the System Full Setting the SystemUnsetting the System Normal EntrySlow Entry Cancelling Alarms Alarm AbortEngineer Reset Page User Menu Option 1 OmitSelecting the Omit Option Option 2 Chime Option 3 WalkOption 4 Codes Selecting the Codes optionAssigning Modifying and Deleting User Codes Keyswitch Zones and User Codes Assigning User AttributesOption 5 Test Option 9 LogOption 10 Time Selecting the Time OptionOperation of the Time Option Appendix a Alarm and Help Messages Page Appendix B Avoiding False Alarms Page Appendix C Conformity and Standards ComplianceTelecoms Page Zone Reference Table IU1-0016 Rev

16, 16 Plus specifications

The Honeywell 16 and 16 Plus are advanced security systems designed to provide robust monitoring and control capabilities for residential and commercial properties. Known for their reliability and ease of use, these systems are ideal for users looking to enhance their security infrastructure.

One of the standout features of the Honeywell 16 is its compatibility with a broad range of security devices, including intrusion sensors, fire alarms, and environmental monitoring equipment. This versatility enables users to customize their security setup according to specific needs, making it suitable for various applications.

A significant technological advancement found in the Honeywell 16 Plus is its Smart Response technology. This feature utilizes real-time data analytics to improve response times, ensuring that alerts are acted upon quickly. It enhances situational awareness by providing users with critical information through a mobile app, allowing for remote monitoring and control from virtually anywhere.

The user interface of the Honeywell 16 and 16 Plus is intuitive, making it accessible even for those with limited technical knowledge. The systems boast an easy-to-navigate touchscreen display, enabling users to manage settings and view system status at a glance. The app integration allows users to arm or disarm the system, view live camera feeds, and receive notifications directly on their devices.

In terms of security protocols, both models feature advanced encryption methods to secure communications between the control panel and connected devices. This protects against unauthorized access and ensures data integrity, a critical consideration in today’s cybersecurity landscape.

Connectivity is another area where the Honeywell 16 and 16 Plus excel. They support a variety of communication methods, including Wi-Fi and cellular, providing reliable backup options to ensure that the system remains operational even during power outages or network disruptions.

These systems also prioritize scalability. Users can easily add additional sensors, cameras, and other devices without requiring significant system overhauls. This flexibility allows for the accommodation of growing security needs over time.

Overall, the Honeywell 16 and 16 Plus deliver a comprehensive security solution characterized by their versatility, user-friendly interfaces, advanced technologies, and strong security measures. They are well-suited for modern demands and continue to be popular choices for users seeking dependable security systems.