APPENDIX A — ALARM AND HELP MESSAGES

ALARM IS ACTIVE: The system is currently in alarm and must be cancelled by a valid user code.

PA RESET REQUIRED: The user code that cancelled the PA alarm does not have the authori- sation to reset the system. A user code with the PA Reset attribute enabled must be entered. The PA switch which created the alarm may also have to be reset.

ENGINEER RESET REQUIRED: This message is displayed when a tamper alarm occurs. Tamper alarms usually require an engineer to visit the site and check all modules on the system.

INTRUDER RESET REQUIRED: The user code that cancelled the alarm does not have the authorisation to reset the system. A user code with the PA Reset attribute enabled must be entered. The PA switch which created the alarm may also have to be reset.

CALL ALARM CO / QUOTE NUMBER XXXXX: This message is displayed on a system with the Technistore reset facility enabled after an alarm has been cancelled. The alarm company should be informed that Technistore reset is required (quoting the number on the keypad display).

INVALID CODE: The code that was entered is not registered in the system memory.

DUPLICATED CODE: When assigning new user codes, the code entered has already been assigned to a code.

TIMED TIMEOUT DISABLED: When setting the system, the exit time has been set to infinity and a Final zone or Push-to-Set zone is used to act as the exit terminator.

TELECOM FAILURE: A fault has occurred with the telephone line or remote signalling which will require engineer attention.

STU LINE FAIL: A fault has occurred with the telephone line or remote signalling which will require engineer attention.

13

Image 23
Contents Galaxy 16 and 16 plus Page Table of Contents Option 9 Log Introduction Page Quick Operation Guide Viii Glossary of Terms Page Keypad Information ¸ # Star ¸ Key FeaturesFull Setting the System Setting and Unsetting the SystemSetting the System Before Setting the SystemSlow Entry Unsetting the SystemNormal Entry Engineer Reset Cancelling AlarmsAlarm Abort Page Selecting the Omit Option User MenuOption 1 Omit Option 3 Walk Option 2 ChimeAssigning Modifying and Deleting User Codes Option 4 CodesSelecting the Codes option Assigning User Attributes Keyswitch Zones and User CodesOption 9 Log Option 5 TestOperation of the Time Option Option 10 TimeSelecting the Time Option Appendix a Alarm and Help Messages Page Appendix B Avoiding False Alarms Page Telecoms Appendix C Conformity and StandardsCompliance Page Zone Reference Table IU1-0016 Rev

16, 16 Plus specifications

The Honeywell 16 and 16 Plus are advanced security systems designed to provide robust monitoring and control capabilities for residential and commercial properties. Known for their reliability and ease of use, these systems are ideal for users looking to enhance their security infrastructure.

One of the standout features of the Honeywell 16 is its compatibility with a broad range of security devices, including intrusion sensors, fire alarms, and environmental monitoring equipment. This versatility enables users to customize their security setup according to specific needs, making it suitable for various applications.

A significant technological advancement found in the Honeywell 16 Plus is its Smart Response technology. This feature utilizes real-time data analytics to improve response times, ensuring that alerts are acted upon quickly. It enhances situational awareness by providing users with critical information through a mobile app, allowing for remote monitoring and control from virtually anywhere.

The user interface of the Honeywell 16 and 16 Plus is intuitive, making it accessible even for those with limited technical knowledge. The systems boast an easy-to-navigate touchscreen display, enabling users to manage settings and view system status at a glance. The app integration allows users to arm or disarm the system, view live camera feeds, and receive notifications directly on their devices.

In terms of security protocols, both models feature advanced encryption methods to secure communications between the control panel and connected devices. This protects against unauthorized access and ensures data integrity, a critical consideration in today’s cybersecurity landscape.

Connectivity is another area where the Honeywell 16 and 16 Plus excel. They support a variety of communication methods, including Wi-Fi and cellular, providing reliable backup options to ensure that the system remains operational even during power outages or network disruptions.

These systems also prioritize scalability. Users can easily add additional sensors, cameras, and other devices without requiring significant system overhauls. This flexibility allows for the accommodation of growing security needs over time.

Overall, the Honeywell 16 and 16 Plus deliver a comprehensive security solution characterized by their versatility, user-friendly interfaces, advanced technologies, and strong security measures. They are well-suited for modern demands and continue to be popular choices for users seeking dependable security systems.