Honeywell 800-08091V3 How to View the Event Log, How to Send Emergency Messages, Panic or Medical

Page 17

Security (cont'd)

How to View the Event Log

Your system has the ability to record various events in a history log wherein each event is recorded with the time and date of its occurrence. The control panel must be programmed to record various system events in the installer programming mode.

To view the Event Log, perform the following:

 

ICON

 

ACTION

NOTES

 

 

 

1.

From the “Home” screen, press Security and

Note: While keypad is requesting and receiving the event log data from the

 

 

 

 

 

 

then the MORE CHOICES icon.

control panel, the "Event Log" screen displays "Please Wait!"

 

 

 

 

 

 

 

 

 

2.

Press the EVENT LOGS icon; the first ten

The Next>> and <<Previous icons are shown for commercial panels only

 

 

 

 

 

 

 

 

events are displayed.

when 100 or more events are in the log. They are not shown for residential

 

 

 

 

 

 

panels.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3.

Press the SHOW MORE button to view all

When All Partitions or All Events icon is pressed, and more than 100

 

 

 

 

 

 

items, and press the up/down arrows to scroll

events exist, the Next>> and <<Previous icons are displayed showing the

 

 

 

 

 

 

through the event log.

next 100 or previous 100 events.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

How to Send Emergency Messages

An emergency message for fire, panic, or medical can be sent to the central monitoring station from the Emergency screen. The Emergency screen can be accessed by activating the "PANIC" Icon located on the lower right corner of the screen.

Perform the following to send an emergency message.

ICON

ACTION

NOTES

 

 

 

 

1. Press the PANIC Icon.

You are immediately returned to the screen from which you pressed the

 

2. Press and hold (for at least 2 seconds) the

“PANIC” Icon.

 

associated alarm icon (FIRE, PANIC, SILENT

NOTE: The Emergency screen cannot be accessed while running a

 

screen diagnostic test or while in the clean screen mode.

 

PANIC or MEDICAL).

 

 

Emergency Icons

Fire

Panic

Silent Panic

Medical

Emergency messages are optional and may not be available on your system. Ask your system installer if emergency messages are available on your system.

UL

Medical functionality has not been evaluated by UL and may not be used in UL Listed applications.

17

Image 17
Contents 800-08091V3 4/13 Rev. a Tuxedo Touch Serriieess Home Automation Systeemm User GuideTable of Contents MULTI-MEDIA User System Setup Navigating through the Tuxedo Touch Keypad About the SystemIntroduction About Your Home Screen About the System contdMulti-Media Application Weather ForecastNavigation Icon Descriptions Icon Function System TroublesUser Codes Safe ModeExtended Functionality LED OperationSecurity Exit Entry Perimeter Interior Mode Delay ArmedIntroduction to Security System Operation ArmingSecurity contd How to Arm the SystemHow to Arm Multiple Partitions How to Bypass Zones How to Display FaultsDisplay Faults icon Press the Bypass Selected iconSystem as Ready to Arm How to Clear Bypassed ZonesHow to Disarm the System Press the Arm Multi-Partition icon How to Check the Status of Other PartitionsFire and Carbon Monoxide Alarm Operation Silencing and Clearing a Fire/Carbon Monoxide Alarm Case of Fire AlarmAdvanced System Features How to Clear/Hide a Control Panel MessageConsole Emulation Mode More ChoicesPanic or Medical How to View the Event LogHow to Send Emergency Messages Brightness and Volume Control SetupAudio Set up icon Operating ModesAdjust the Screen Timeouts Setup contdClean Screen Press the Disp & Audio Setup iconWeb Server/Hosting Setup cont’dIP Setup IP Setup icon Voice Messages Multi-MediaPicture Setup Video Audio SetupMulti-Media contd Video IconsPicture Icons Camera SetupMulti-Media cont’d Setup Icons Camera Icons Authority Levels User SetupHow to Add a User How to Add an Existing User to a Second Keypad User Setup contdHow to Delete a User How to Edit a UserPress the OK icon Select Safe Mode and then press ApplyTo exit, press the safe mode bar and press Setup icons Setting Daylight Savings TimeSetting Current Time and Date System Information User System SetupAdvanced Setup Wave Primary Controller Shift to Secondary icon User System Setup contdOutput Setup Icons Automation Enroll a Light, Switch or Outlet ModuleEnroll/Add Z-Wave Devices Press the Z-Wave Enroll/ Add iconEnroll a Door Lock Automation contdEnroll a Honeywell Thermostat Press the Z-Wave Enroll/Add iconEditing Z-Wave Device Names Remove a Light, Switch or Outlet ModuleRemove/Delete Z-Wave Devices Edit a Device Module NameAt the thermostat Then press the Z-Wave Setup icon to displayFollow the instructions in the thermostat Thermostat is removedPress the Automation and Scene Setup icons Scene SetupScene Icons Scene RulesScene Setup Options Room Setup icon Setting a Secondary Keypad ControllerRoom Setup Icons Create a RoomUpdating Controllers Keypads with New or Removed devices Wave TroubleshootingRemoving a Secondary Controller Keypad Device RemovedControlling Device Remote ServicesScenes created in Total Connect Scenes created in Tuxedo Edit ScenesControlling Automation Z-Wave Devices Remotely Door Locks Compatible DevicesImportant Notes Wireless RangeGlossary Industry Canada Class B Statement TWO Year Limited Warranty Ê800-08091V3RŠ

800-08091V3 specifications

The Honeywell 800-08091V3 is a state-of-the-art control panel component that is recognized for its outstanding performance in the realm of security and monitoring systems. Designed to enhance the capabilities of Honeywell’s powerhouse security solutions, this product boasts a variety of features and technological advancements that ensure reliability and efficiency in protecting both residential and commercial properties.

One of the primary features of the Honeywell 800-08091V3 is its intuitive user interface, which allows for seamless navigation and easy access to critical information. The panel is designed with usability in mind, providing users with a straightforward means to monitor their security systems. This emphasis on user experience extends to the programming and customization options available, enabling users to tailor settings according to their specific needs.

Technologically, the Honeywell 800-08091V3 employs advanced communication protocols that ensure rapid data transmission and connectivity. It supports both wired and wireless communication, enhancing its versatility in various installations. This feature is particularly crucial for businesses or homeowners looking to implement a robust security system without the limitations of traditional wiring methods.

The Honeywell 800-08091V3 is also compatible with a wide range of security devices, including sensors, alarms, and surveillance cameras. This compatibility allows for an integrated system that can centralize control and monitoring, significantly improving response times and situational awareness. Its ability to interface with additional Honeywell products provides users with the flexibility to expand their security solutions as needs change.

In terms of characteristics, the Honeywell 800-08091V3 is designed for durability and longevity. It features a rugged construction that withstands environmental factors, making it suitable for both indoor and outdoor installations. Moreover, its power management capabilities ensure that the system remains operational during power outages, providing continuous protection without interruption.

Overall, the Honeywell 800-08091V3 exemplifies a commitment to innovation in security technology. Its key features, like an easy-to-use interface, advanced communication capabilities, extensive compatibility with other security devices, and robust construction, make it an ideal choice for those seeking a reliable and efficient security solution. Whether for home use or larger commercial applications, the Honeywell 800-08091V3 stands out as a prime example of modern security technology, ensuring peace of mind for users everywhere.