Honeywell 800-08091V3 manual Create a Room, Setting a Secondary Keypad Controller, Room Setup icon

Page 39

Automation (cont'd)

Notes:

1.Motorized door lock bolts physically lock and unlock the door when activated, but if the door lock installed is a non-motorized type, activation allows the door to be manually unlocked without a key. See “Compatible Devices” section for further information.

2.Some thermostats do not update temperature status automatically (i.e., Wayne Dalton).

3.When using a Kwikset Smartcode Electronic Deadbolt door lock (in a Scene that is programmed to trigger when unlocked) the Scene does not trigger if using a key; enter a user code.

Create a Room

Multiple devices can function as a group by associating them in a “Room”. Follow the procedure below to create a Room.

ICON

 

ACTION

 

NOTES

 

1. Press the Automation icon and then press the

Room names (i.e., All, etc.) are displayed across the top to the screen.

 

Room Setup icon.

 

 

Enter the new device name by entering it on the data entry keyboard.

 

2. Press the Add icon and enter a room name on the

Use the Shift icon for capital letters.

 

“Data Entry” keyboard.

 

Use the BS (Backspace) icon to make corrections.

 

 

The @#$ icon is not available for use at this time.

 

3. Press OK.

 

 

 

 

 

 

 

4. Highlight the device(s) from the list that you want

Use the Edit and Delete icon to rename, or delete a room.

 

to add to this Room and press the Save icon.

 

Room Setup Icons

 

 

 

Delete

Edit

Add

Save

 

 

 

 

 

Setting a Secondary (Keypad) Controller

After all Z-Wave devices have been enrolled into the Primary (Keypad) Controller, the device information can be downloaded to a Secondary (Keypad) Controller. Keep the controllers within 10 feet of each other, apply power to the Secondary Controller and do the following:

ICON

 

ACTION

NOTES

 

1. At the Primary Controller:

If used for Remote Services, Tuxedo should not be configured as

 

a) Press the Automation icon from the “Home” screen

a secondary controller. See the Remote Services section.

 

 

and then press the Z-Wave Setup icon to display the

Note: Up to 232 Secondary Controllers can be added.

 

 

“Z-Wave Device Management” screen.

When the Primary Controller icon is pressed, the message is

 

 

displayed:

 

2. At the Secondary Controller:

 

“Please remove all Z-wave devices from network first”

 

a) Remove any Z-Wave devices that have been added.

The message is displayed: “Scanning for Devices”

 

b)

Press the Z-Wave Primary icon (located in the lower

The message is displayed: “Updating Devices. Please Wait”.

 

c)

right side of the screen).

When the device information from the Primary Controller is

 

Select Yes to change this keypad to a Secondary

downloaded to the Secondary Controller:

 

 

Controller.

the Secondary Controller displays, “Controller Add Success”

 

3. At the Primary Controller: Press Add.

the Primary Controller displays, “Device Added Successfully”

 

4. At the Secondary Controller: Press Add.

 

39

Image 39
Contents 800-08091V3 4/13 Rev. a Tuxedo Touch Serriieess Home Automation Systeemm User GuideTable of Contents MULTI-MEDIA User System Setup About the System IntroductionNavigating through the Tuxedo Touch Keypad Weather Forecast About the System contdAbout Your Home Screen Multi-Media ApplicationNavigation Icon Descriptions Icon Function System TroublesLED Operation Safe ModeUser Codes Extended FunctionalityArming Exit Entry Perimeter Interior Mode Delay ArmedSecurity Introduction to Security System OperationHow to Arm the System How to Arm Multiple PartitionsSecurity contd Press the Bypass Selected icon How to Display FaultsHow to Bypass Zones Display Faults iconHow to Clear Bypassed Zones How to Disarm the SystemSystem as Ready to Arm How to Check the Status of Other Partitions Fire and Carbon Monoxide Alarm OperationPress the Arm Multi-Partition icon Silencing and Clearing a Fire/Carbon Monoxide Alarm Case of Fire AlarmMore Choices How to Clear/Hide a Control Panel MessageAdvanced System Features Console Emulation ModeHow to View the Event Log How to Send Emergency MessagesPanic or Medical Operating Modes SetupBrightness and Volume Control Audio Set up iconPress the Disp & Audio Setup icon Setup contdAdjust the Screen Timeouts Clean ScreenSetup cont’d IP SetupWeb Server/Hosting IP Setup icon Voice Messages Multi-MediaVideo Icons Video Audio SetupPicture Setup Multi-Media contdCamera Setup Multi-Media cont’dPicture Icons Setup Icons Camera Icons User Setup How to Add a UserAuthority Levels How to Edit a User User Setup contdHow to Add an Existing User to a Second Keypad How to Delete a UserSelect Safe Mode and then press Apply To exit, press the safe mode bar and pressPress the OK icon Setting Daylight Savings Time Setting Current Time and DateSetup icons User System Setup Advanced SetupSystem Information Wave Primary Controller Shift to Secondary icon User System Setup contdOutput Setup Icons Press the Z-Wave Enroll/ Add icon Enroll a Light, Switch or Outlet ModuleAutomation Enroll/Add Z-Wave DevicesPress the Z-Wave Enroll/Add icon Automation contdEnroll a Door Lock Enroll a Honeywell ThermostatEdit a Device Module Name Remove a Light, Switch or Outlet ModuleEditing Z-Wave Device Names Remove/Delete Z-Wave DevicesThermostat is removed Then press the Z-Wave Setup icon to displayAt the thermostat Follow the instructions in the thermostatScene Rules Scene SetupPress the Automation and Scene Setup icons Scene IconsScene Setup Options Create a Room Setting a Secondary Keypad ControllerRoom Setup icon Room Setup IconsDevice Removed Wave TroubleshootingUpdating Controllers Keypads with New or Removed devices Removing a Secondary Controller KeypadEdit Scenes Remote ServicesControlling Device Scenes created in Total Connect Scenes created in TuxedoControlling Automation Z-Wave Devices Remotely Door Locks Compatible DevicesImportant Notes Wireless RangeGlossary Industry Canada Class B Statement TWO Year Limited Warranty Ê800-08091V3RŠ

800-08091V3 specifications

The Honeywell 800-08091V3 is a state-of-the-art control panel component that is recognized for its outstanding performance in the realm of security and monitoring systems. Designed to enhance the capabilities of Honeywell’s powerhouse security solutions, this product boasts a variety of features and technological advancements that ensure reliability and efficiency in protecting both residential and commercial properties.

One of the primary features of the Honeywell 800-08091V3 is its intuitive user interface, which allows for seamless navigation and easy access to critical information. The panel is designed with usability in mind, providing users with a straightforward means to monitor their security systems. This emphasis on user experience extends to the programming and customization options available, enabling users to tailor settings according to their specific needs.

Technologically, the Honeywell 800-08091V3 employs advanced communication protocols that ensure rapid data transmission and connectivity. It supports both wired and wireless communication, enhancing its versatility in various installations. This feature is particularly crucial for businesses or homeowners looking to implement a robust security system without the limitations of traditional wiring methods.

The Honeywell 800-08091V3 is also compatible with a wide range of security devices, including sensors, alarms, and surveillance cameras. This compatibility allows for an integrated system that can centralize control and monitoring, significantly improving response times and situational awareness. Its ability to interface with additional Honeywell products provides users with the flexibility to expand their security solutions as needs change.

In terms of characteristics, the Honeywell 800-08091V3 is designed for durability and longevity. It features a rugged construction that withstands environmental factors, making it suitable for both indoor and outdoor installations. Moreover, its power management capabilities ensure that the system remains operational during power outages, providing continuous protection without interruption.

Overall, the Honeywell 800-08091V3 exemplifies a commitment to innovation in security technology. Its key features, like an easy-to-use interface, advanced communication capabilities, extensive compatibility with other security devices, and robust construction, make it an ideal choice for those seeking a reliable and efficient security solution. Whether for home use or larger commercial applications, the Honeywell 800-08091V3 stands out as a prime example of modern security technology, ensuring peace of mind for users everywhere.