Whirlpool AD050, ADO25, AD040, AD030 Adjusting the water level control lever, De-icer control

Page 9

De-icer control

Product Damage Hazard

Do not operate dehumidifier at tem- peratures below 65°F (18.3%).

Failure to follow the above precaution could result in the coils icing over and the unit not operating properly.

Your Whirlpool dehumidifier is equipped with a feature to help you get the most comfort from your new appliance by permitting it to operate down to 65°F (18.3%). If your dehumidifier runs when room temperature and humidity conditions are low, frost can form on its evaporator coil. This interferes with proper operation.

The De-icer Control senses frost build-up on the evaporator coil and automatically shuts off the compressor. The fan continues to run, drawing air across the coil and melting the frost. When the coil is defrosted, the compressor is automatically restarted, and dehumidifying is resumed.

Adjusting the water level control lever

The Water Level Adjustment can be set in two positions to turn off the unit automati- cally when the pan is full. This prevents the danger of overflow.

Pan must be in proper position for Water Level Control Switch to work. The Water Level Control Switch will automatically turn off the dehumidifier at the fill level you selected when pan is properly placed. Loosen the screw to move the Water Level Control Lever. Retighten screw when adjusted to desired setting.

NORMAL fill position

Set Water Level Control Lever to the inden- tation on the left side. The water pan and water will weigh approximately 16 Ibs.

(7.2 kg) and water pan will be l/2 full.

MAXIMUM fill position

Set Water Level Control Lever to the raised area on the right side. The water pan and water will weigh approximately 24 Ibs.

(10.8 kg) and water pan will be %I full.

Water level

Normal

Sciew

~Maximum

fill position

 

fill position

Image 9
Contents Models ADO25 AD030 Thank you for buying a Whirlpool@ appliance Your safety is important to usOur Consumer Center Number 800-253-1 301 Is toll-free Hours a DayHelp us help you Important Safety InstructionsKrts And Fkmtum Before Using Your Dehumidifier Installing it properlyThis Section Meeting electrical requirements Recommended grounding methodObserve ALL Governing Codes and Ordinances Choosing the proper location for your dehumidifier Using Your DehumidifierPerating your dehumidifier Control panelUnit operation De-icer control Adjusting the water level control leverDisposing of collected water Caring For Your Performing annual maintenancePage Before calling for service If You Need Assistance Or ServiceProblem Possible SolutionIf you are not satisfied with How the problem was solved If you need service’If you need assistance If you need FSP@ replace- ment partsWhirlpool will not PAY for Dehumidifier Warranty