Heath Zenith 598-1347-00 Check Operation and Adjustment, DualBrite Dimmer Control

Models: 598-1347-00

1 32
Download 32 pages 35.09 Kb
Page 4
Image 4
Check Operation and Adjustment

Check Operation and Adjustment

Note: When first turned on or when switching modes wait 30 seconds.

Note: Meets the ENERGY STAR® guidelines when DualBrite® function is off.

Locate the RANGE control and ON-TIME control on the motion sensor:

TheRANGEcontrolandON-TIMEcontrolarelocatedonthebottom of the motion sensor. Using your fingernails or a small, flat-head screwdriver, gently pry the cover until it opens.

1.Check Operation. Set the ON-TIME control to TEST mode. Walk in front of motion sensor. The LED indicator light should flash when motion is detected (see illustration for location of LED light).

2.Adjust Motion Sensor. Turn the RANGE control to the mid posi- tion and ON-TIME control to the TEST position. Walk through coverage area noting where you are when the LED begins to flash. Loosen the clamp screw and move the motion sensor to change the coverage area. Tighten clamp screw when finished.

Do not overtighten clamp screw.

3.Adjust RANGE Control. To increase sensitivity, turn the RANGE control toward MAX. To decrease sensitivity, turn the RANGE control toward MIN. Note: If the RANGE is set too high, false triggering may result in some environments.

Note: When using test mode to check operation in the day time:

A.Set the DETECT control switch to DAY/NIGHT and

B.Set the ON-TIME control to TEST.

 

 

 

Range

ON-TIME

ON-TIME

RANGE

Control

Control

(MINUTES)

MAX

MIN

 

 

 

 

5 1 TEST

 

 

LED

Indicator

180° Motion Sensor Controls

4.Set ON-TIME Control. Determine the amount of time you want the connected device to stay on after motion is detected (1 or 5 minutes). Slide the ON-TIME control to the corresponding setting.

DualBrite® Dimmer Control

(240° Motion Sensor Only)

Light comes on half power for selected time after dusk (Off, 3 or 6 hours, until dawn). When motion is sensed, the light turns on full power for the selected ON-TIME (1 or 5 minutes) then returns to accent mode.

1.Select amount of time desired for accent lighting (DualBrite® control).

Off

3 Hours

6 Hours

Dusk to Dawn

IMPORTANT: Avoid Aiming Motion Sensor At:

Objects that change temperature rapidly, such as heating vents, fans, and air conditioners. These air sources could cause false triggering.

Areas where pets or traffic may trigger the control.

Nearby large, light colored objects reflecting light may trigger the shut-off feature. Do not point other lights at motion sensor.

LED Indicator

 

 

 

Range

 

 

RANGE

Control

 

MAX

MIN

 

DualBrite®

DUSKTO 6 3 OFF

TEST 1 5

ON-TIME

DAWN HRS

(MINS)

Control

DUALBRITE™

ON-TIME

Control

240° Motion Sensor Controls

598-1347-00

Page 4
Image 4
Heath Zenith 598-1347-00 Check Operation and Adjustment, DualBrite Dimmer Control, Motion Sensor Controls

FAQ

How do I check the operation of the motion sensor?

Set the ON-TIME control to TEST mode, walk in front of the sensor, and observe the LED indicator light flashing when motion is detected.

How can I adjust the sensitivity of the motion sensor?

Turn the RANGE control toward MAX to increase sensitivity or toward MIN to decrease sensitivity. Be cautious of false triggering if the RANGE is set too high in certain environments.

What should I avoid aiming the motion sensor at?

Avoid aiming the motion sensor at objects that change temperature rapidly, areas where pets or traffic may trigger the control, and nearby large, light-colored objects that may trigger the shut-off feature.