FILTSEL – Filter Select

This command turns on and off the filters.

Command Form: DEVICE FILTSEL <Channel> <Group> <Node> [Value]

Argument

Type

Size

Values

Units

Channel

Channel

1

See Groups and Channels

Group

Group

1

3, 5 (M, P)

 

Node

Unsigned Integer

1

Group 3

1 – 4

 

 

 

 

 

0xFF for all (*

 

 

 

 

 

text)

 

 

 

Group 5

1 – 15

 

 

 

 

 

0xFF for all (*

 

 

 

 

 

text)

Value

Unsigned Integer

1

0

= Off

 

 

 

 

1

= On

 

 

 

 

2

= Toggle

 

 

 

 

(Null to query in text)

 

FLOW – Flow Control

This command selects/reports the flow control of the serial port on the unit. Hardware flow control is implemented using DTR and DSR.

Command Form: DEVICE FLOW [Value]

Argument

Type

Size

Values

Units

Value

Unsigned Integer

4

0

= Off

 

 

 

 

1

= On

 

 

 

 

2

= Toggle

 

 

 

 

(Null to query in text)

 

FMP – First Mic Priority Mode

This command selects/reports first Mic priority mode.

Command Form: DEVICE FMP <Channel> [Value]

Argument

Type

Size

Values

Units

Channel

Channel

1

See Groups and Channels

 

Group

Group

1

4

(G)

 

Value

Unsigned Integer

2

0

= Off

 

 

 

 

1

= On

 

 

 

 

2

= Toggle

 

 

 

 

(Null to query in text)

 

GAIN – Gain Adjustment

This command changes or reports back the gain for a channel.

Command Form: DEVICE GAIN <Channel> <Group> [Value] [Absol/Rel]

Argument

Type

Size

Values

Units

Channel

Channel

1

See Groups and Channels

 

Group

Group

1

1, 2, 3, 5, 7, 12, 16, 17 (I, J, O, M, P, L, F, T, R)

 

Value

Signed

2

-99.90 – 99.90 **

dB

 

Float

 

(Null to query in text)

 

Absol / Rel

 

0

A = Absolute

 

 

 

 

R = Relative

 

 

 

 

Null = Relative

 

NOTE: Values indicate valid range for entry values only. Actual internal range of the gain stage is from –65 to 20. Absolute values will be limited to the internal gain range.

243

Page 248
Image 248
ClearOne comm SR 1212 Filtsel Filter Select, Flow Flow Control, FMP First Mic Priority Mode, Gain Gain Adjustment, 243