PANGAT – PA Noise Gate Activation Timer

This command sets the Noise Gate activation timer. The noise gate will be activated if the timer conditions are met along with Gate thresholds.

Command Form: DEVICE PANGAT <Channel> <Group> [Value]

Argument

Type

Size

Values

Units

Channel

Channel

1

See Groups and Channels

 

Group

Group

1

23 (J)

 

Value

Unsigned Short

2

1 -16

Minutes

 

 

 

(Null to query in text)

 

PANGEN – PA Noise Gate Enabled

This command enables noise gating on a PA Channel.

Command Form: DEVICE PANGEN <Channel> <Group> [Value]

Argument

Type

Size

Values

Units

Channel

Channel

1

See Groups and Channels

 

Group

Group

1

23 (J)

 

Value

Unsigned Short

2

0

= No Filter

 

 

 

 

1

= High Pass

 

 

 

 

2

= Low Pass

 

 

 

 

3

= Hi and Low Pass

 

 

 

 

(Null to query in text)

 

PANGF – PA Noise Gate Filter

This command sets either a High Pass or Low Pass filter to be used in the activation of the noise gate. This will affect the threshold conditions for activation of the gate. A low pass will remove noise floor contributions to gate threshold above 500 HZ. A high pass will remove noise floor contribution to gate threshold above below 2K.

Command Form: DEVICE PANGF <Channel> <Group> [Value]

Argument

Type

Size

Values

Units

Channel

Channel

1

See Groups and Channels

 

Group

Group

1

23 (J)

 

Value

Unsigned Short

2

0

= Off

 

 

 

 

1

= On

 

 

 

 

2

= Toggle

 

 

 

 

(Null to query in text)

 

PANGM – PA Noise Gate Mode

This command sets the Noise Gate mode to be either manual or automatic. In manual mode the gate threshold will be used to activate. In auto mode the noise floor will be used to activate.

Command Form: DEVICE PANGM <Channel> <Group> [Value]

Argument

Type

Size

Values

Units

Channel

Channel

1

See Groups and Channels

 

Group

Group

1

23 (J)

 

Value

Unsigned Short

2

0

= Automatic

 

 

 

 

1

= Manual

 

 

 

 

(Null to query in text)

 