LOCSTATE – Location: State

This command sets/reports the location of the unit: State/Prefecture string.

Command Form: DEVICE LOCSTATE [Value]

Argument

Type

Size

Values

Units

Value

String

80

CLEAR = Clear current value

 

 

 

 

1 – 63 Characters

 

 

 

 

(Null to query in text)

 

LOGMASK – Device Log Mask

This command sets or reports the device event log mask.

Command Form: DEVICE LOGMASK [Value]

Argument

Type

Size

Values

Units

Value

Hexadecimal

4

XXXX XXXX XXXX XXXX XXXX XXXX XXXX XXXX

 

 

 

 

> Reset

 

 

 

 

> Errors

 

 

 

 

> Password Access

 

 

 

 

> Telco On/Off

 

 

 

 

> Dial

 

 

 

 

> Call Duration

 

 

 

 

> System Checks

 

 

 

 

> Firmware Download

 

 

 

 

> (Reserved)

 

 

 

 

> Default

 

 

 

 

> (Reserved)

 

 

 

 

> (Reserved)

 

 

 

 

> Safety Mute

 

 

 

 

> Macro Execution

 

 

 

 

> Preset Execution

 

 

 

 

> Audio Clipping

 

 

 

 

-> Microphone Gains

 

 

 

 

-> Processor Gains

 

 

 

 

-> Fader Gains

 

 

 

 

-> Telco Gains

 

 

 

 

-> Power Amp. Gains

 

 

 

 

-> Power Amp. Errors

 

 

 

 

-> Caller ID

 

 

 

 

-> SIP Message Log

 

 

 

 

-------

-> (Reserved)

 

(Null to query in text)

LVL – Level

This command reports the level of a channel. This command is read only.

Command Form: DEVICE LVL <Channel> <Group> <Position> [Value]

Argument

Type

Size

Values

Units

Channel

Channel

1

See Groups and Channels

 

Group

Group

1

1, 2, 3, 5, 7, 12, 16, 17, 20

 

 

 

 

(I, J, O, M, P, L, F, T, R)

 

Position

Meter Type

2

See Meter Type Definitions

 

Value

Signed Float

4

-99.99 – 99.99

dB

 

 

 

(Sent with Null in text, Value returned)

 

248

Page 253
Image 253
ClearOne comm PRO 8I, PRO TH20, SR 1212 operation manual Locstate Location State, Logmask Device Log Mask, LVL Level, 248