FES – Feedback Elimination Setup

This command reset the feedback eliminator and initiates an automatic training cycle. When the automatic setup is complete, the FESC (Feedback Elimination Setup Complete) command will be issued. There is no query associated with this command.

Command Form: Device FES<Channel> <Group> [Value]

Argument

Type

Size

Values

Units

Channel

Channel

1

See GroupAndChannels

 

Group

Group

1

23 (J)

 

Reserved

Zero

2

Zero

 

FESC – Feedback Elimination Setup Complete

This command reports when the automatic feedback eliminator setup training cycle is in progress. The training cycle is started using the command FES (Feedback Elimination Setup). This is a query only command.

Command Form: Device FESC<Channel> <Group> [Value]

Argument

Type

Size

Values

Units

Channel

Channel

1

See GroupAndChannels

 

Group

Group

1

23 (J)

 

Value

Unsigned Short

2

0

= Setup Complete

 

 

 

 

1

= Setup in Progress

 

 

 

 

(Sent Null, Value Returned)

 

FILTER – Filter Adjust

This command selects/reports the settings of a filter.

Command Form: DEVICE FILTER <Channel> <Group> <Node> [Type Frequency Gain/Slope Bandwidth/ Subtype]

Argument

Type

Size

Values

 

 

Units

Channel

Channel

1

See Groups and Channels

 

Group

Group

1

3, 5 (M, P)

 

 

 

Node

Unsigned

1

Group 3

1

– 4

 

 

Integer

 

Group 5

1

– 15

 

Type

Unsigned

1

0

= None

 

 

 

 

Integer

 

1

= All Pass

 

 

 

 

 

 

2

= Low Pass

 

 

 

 

 

 

3

= High Pass

 

 

 

 

 

 

4

= Low Shelving

 

 

 

 

 

 

5

= High Shelving

 

 

 

 

 

 

6

= Parametric Equalizer

 

 

 

 

 

7

= CD Horn

 

 

 

 

 

 

8

= Bessel Crossover

 

 

 

 

 

 

9

= Butterworth Crossover

 

 

 

 

10 = Linkwitz-Riley Crossover

 

 

 

 

11 = Notch

 

 

 

 

 

 

(Null to query in text)

 

 

 

Frequency

Unsigned

4

Type 0

0

(Null in text)

Hz

 

Float

 

Type 1 – 6, 8 – 11

20.00 – 20000.00

 

 

 

 

Type 7

500.00 – 5000.00

 

Gain/Slope

Signed Float

2

Type 0 – 3, 7, 11

0

(Null in text)

dB /

 

 

 

Type 4 – 6

-15.00 – 15.00

dB per

 

 

 

Type 8 – 9

12, 18, 24

Octave

 

 

 

 

 

 

 

Type 10

12, 24

 

Bandwidth/Subtype

Unsigned

2

Type 0 – 5, 7

0

(Null in text)

Octaves /

 

Float

 

Type 6, 11

0.05 – 5.00

Type

 

 

 

Type 8 – 10

2

= Low Pass

 

 

 

 

 

 

3

= High Pass

 

242

Page 247
Image 247
ClearOne comm PRO 8I, PRO TH20, SR 1212 operation manual Filter Filter Adjust, 242