ClearOne comm PRO TH20 Siggensweep Signal Generator Sweep, Sigtout Signal Generator Time Out, 268

Models: SR 1212 PRO 8I PRO TH20

1 320
Download 320 pages 10.06 Kb
Page 273
Image 273

SIGGENSWEEP – Signal Generator Sweep

This command starts the signal generator with a tone and does a sweep. If Repeat is 0, the signal generator will turn off after the sweep. If Repeat is 1, the signal generator will turn off after signal generator timeout. To stop the sweep, send a SIGGENEN command with a 0. During the sweep, the box will send out updated SIGGEN commands.

Command Form:

DEVICE SIGGENSWEEP <Channel> <Group> <Amplitude> <Start Frequency> <End Frequency> <Increment Frequency> <Rate> <Repeat>

Argument

Type

Size

Values

Units

Channel

Channel

1

See Groups and Channels

 

Group

Group

1

1, 3, 7 (I, M, L)

 

Amplitude

Signed Float

2

-60.00 – 20.00

dB

Start

Unsigned Float

4

20.00 – 20000.00

Hz

Frequency

 

 

 

 

End

Unsigned Float

4

20.00 – 20000.00 (must be greater than the

Hz

Frequency

 

 

start)

 

Increment

Unsigned Float

4

1.00 – 20000.00

Hz

Frequency

 

 

 

 

Rate

Unsigned Integer

2

10 – 2000 ms

Hz

Repeat

Unsigned Integer

2

0 = repeat off

 

 

 

 

1 = repeat on

 

SIGTOUT – Signal Generator Time Out

Sets the signal generator time out for the unit.

Command Form: DEVICE SIGTOUT [Value]

Argument

Type

Size

Values

Units

Value

Unsigned Integer

4

0

= Disable

Min

 

 

 

1

– 30

 

 

 

 

(Null to query in text)

 

SLVL – Speech Level Control

This command selects/reports the setting of Speech Level Control.

Command Form: DEVICE SLVL <Channel> [Value]

Argument

Type

Size

Values

Units

Channel

Channel

1

See Groups and Channels

 

Group

Group

1

3

(M)

 

Value

Unsigned Integer

2

0

= Off

 

 

 

 

1

= On

 

 

 

 

2

= Toggle

 

 

 

 

(Null to query in text)

 

SMTPSRV – SMTP Mail Server Address

This command selects/reports the IP address of the SMTP Mail server, and the Email Address the unit’s SMTP client sends messages to.

Command Form: DEVICE SMTPSRV [Value Address]

 

Argument

Type

Size

Values

Units

Value

IP Address

4

(Null to query in text)

 

 

 

 

(0.0.0.0 Clears IP and String)

 

Address

String

40

1 – 40 characters

 

 

 

 

(Null to query in text)

 

268

Page 273
Image 273
ClearOne comm PRO TH20 Siggensweep Signal Generator Sweep, Sigtout Signal Generator Time Out, Slvl Speech Level Control