REDIAL – Redial the Last Number

This command redials the last number. There is no query for this command.

Command Form: DEVICE REDIAL <Channel>

Argument

Type

Size

Values

Units

Channel

Channel

1

See Groups and Channels

 

Group

Group

1

17 (R)

 

Reserved

 

2

0

 

REFSEL – Reference Select for PA Adaptation & AEC

This command selects/reports which output or expansion bus reference is used for a Mic input as a reference for power amp adaptation mode and acoustic echo cancellation where applicable.

Command Form: DEVICE REFSEL <Channel> [Ref. Group Ref. Channel]

Argument

Type

Size

Values

Units

Channel

Channel

1

See 3 (M) in Groups and Channels

 

Group

Group

1

3 (M)

 

Reference Group

Group

1

2, 8, 20 (A, B, E, H, J, O)

 

Reference Channel

Channel

1

See Groups and Channels

 

 

 

 

(Null to query in text)

 

REFSET – Reference Channel Set Up

This command selects/reports the output the reference channel tracks.

Command Form: DEVICE REFSET <Channel> [Reference Output]

Argument

Type

Size

Values

Units

Channel

Channel

1

See Groups and Channels

 

Group

Group

1

20 (B)

 

Value

Reference Output

2

0 = none

 

 

 

 

See 2 (O) in Groups and Channels

 

 

 

 

(Null to query in text)

 

RESET – Reset

Resets the unit. There is no query for this command.

Command Form: DEVICE RESET

No Arguments

RING – Ring Indication

This command indicates a ringing line. This command is reportable only. It cannot be queried or set.

Command Form: DEVICE RING <Channel><Value>

Argument

Type

Size

Values

Units

Channel

Channel

1

See Groups and Channels

 

Group

Group

1

17 (R)

 

Value

Unsigned

2

0

= Ring Cycle Ended

 

 

Integer

 

1

= Ring Cycle Started

 

264