PAEQEN – PA EQ Filter Enable

This command enables the EQ filter on a PA Channel

Command Form: DEVICE PAEQEN <Channel> <Group> [Value]

Argument

Type

Size

Values

Units

Channel

Channel

1

See Groups and Channels

 

Group

Group

1

23 (J)

 

Value

Unsigned

2

0

= Off

 

 

Short

 

1

= On

 

 

 

 

2

= Toggle

 

(Null to query in text)

PAEQRST – PA EQ Filter Reset

This command resets the EQ Level for ALL bands in the filter bank. There is no query associated with this command.

Command Form: DEVICE PAEQEN <Channel> <Group> [Value]

 

Argument

Type

Size

Values

Units

Channel

Channel

1

See Groups and Channels

 

Group

Group

1

23 (J)

 

Reserved

Zero

2

Zero

 

PAEQSET – PA EQ Filter Set

This command sets/reports the EQ Level for a given band in the filter bank

Command Form: DEVICE PAEQEN <Channel> <Group> <Band> [Value]

Argument

Type

Size

Values

Units

Channel

Channel

1

See Groups and Channels

 

Group

Group

1

23 (J)

 

 

Band

Unsigned

2

1

=

32.25 Hz

Hz

 

Short

 

2

=

62.5 Hz

 

 

 

 

3

=

125.0 Hz

 

 

 

 

4

=

250.0 Hz

 

 

 

 

5

=

500.0 Hz

 

 

 

 

6

=

1000.0 Hz

 

 

 

 

7

=

2000.0 Hz

 

 

 

 

8

=

4000.0 Hz

 

 

 

 

9

=

8000.0 Hz

 

 

 

 

10 =

16000.0 Hz

 

Value

Signed

4

-12.00 – 12.00

dB

 

Float

 

(Null to query in text)

 

257

Page 262