ClearOne comm PRO 8I, PRO TH20, SR 1212 Paeqrst PA EQ Filter Reset, Paeqset PA EQ Filter Set, 257

Models: SR 1212 PRO 8I PRO TH20

1 320
Download 320 pages 10.06 Kb
Page 262
Image 262

PAEQEN – PA EQ Filter Enable

This command enables the EQ filter on a PA Channel

Command Form: DEVICE PAEQEN <Channel> <Group> [Value]

Argument

Type

Size

Values

Units

Channel

Channel

1

See Groups and Channels

 

Group

Group

1

23 (J)

 

Value

Unsigned

2

0

= Off

 

 

Short

 

1

= On

 

 

 

 

2

= Toggle

 

(Null to query in text)

PAEQRST – PA EQ Filter Reset

This command resets the EQ Level for ALL bands in the filter bank. There is no query associated with this command.

Command Form: DEVICE PAEQEN <Channel> <Group> [Value]

 

Argument

Type

Size

Values

Units

Channel

Channel

1

See Groups and Channels

 

Group

Group

1

23 (J)

 

Reserved

Zero

2

Zero

 

PAEQSET – PA EQ Filter Set

This command sets/reports the EQ Level for a given band in the filter bank

Command Form: DEVICE PAEQEN <Channel> <Group> <Band> [Value]

Argument

Type

Size

Values

Units

Channel

Channel

1

See Groups and Channels

 

Group

Group

1

23 (J)

 

 

Band

Unsigned

2

1

=

32.25 Hz

Hz

 

Short

 

2

=

62.5 Hz

 

 

 

 

3

=

125.0 Hz

 

 

 

 

4

=

250.0 Hz

 

 

 

 

5

=

500.0 Hz

 

 

 

 

6

=

1000.0 Hz

 

 

 

 

7

=

2000.0 Hz

 

 

 

 

8

=

4000.0 Hz

 

 

 

 

9

=

8000.0 Hz

 

 

 

 

10 =

16000.0 Hz

 

Value

Signed

4

-12.00 – 12.00

dB

 

Float

 

(Null to query in text)

 

257

Page 262
Image 262
ClearOne comm PRO 8I, PRO TH20, SR 1212 Paeqrst PA EQ Filter Reset, Paeqset PA EQ Filter Set, 257, Argument Type Size