LABEL – Label

This selects/reports the label of the specific channel or the unit.

Command Form: DEVICE LABEL <Channel> <Group> [In/Out] [Value]

Argument

Type

Size

Values

 

 

Channel

Channel

1

See Groups and Channels

 

 

Group

Group

1

1, 2, 3, 4, 5, 6, 7, 8, 12, 13, 14, 16, 17, 20

 

 

 

(H, I, J, O, M, G, P, E, L, A, F, S, C, T, R, B)

Input / Output to

Unsigned Integer

2

Groups all but 6

0

 

Matrix

 

 

Groups 6

0

= output

 

 

 

 

1

= input

Label

String

20

1 – 20 characters

 

 

 

 

 

CLEAR = clear the label

 

 

 

 

 

(Null to query in text)

 

 

LCDCONTRAST – LCD Contrast

This command selects/reports the LCD Contrast Setting.

Command Form: DEVICE LCDCONTRAST [Value]

Argument

Type

Size

Values

Units

Value

Unsigned Integer

4

0 (lightest) – 63 (darkest)

 

 

 

 

(Null to query in text)

 

LMO – Last Mic On Mode

This command selects/reports last Mic on mode.

Command Form: DEVICE LMO <Channel> [Value]

Argument

Type

Size

Values

Units

Channel

Channel

1

See Groups and Channels

 

Group

Group

1

4

(G)

 

Value

Unsigned Integer

2

0

= Off

 

 

 

 

1

- 8 = Mic 1 – 8 to be the last mic

 

0xFF (* in text) = Last Mic to stay on (Null to query in text)

LOCALNUM – Local Number

This command sets or reports back the current value of the local number.

Command Form: DEVICE LOCALNUM <Channel> [Number]

Argument

Type

Size

Values

Units

Channel

Channel

1

See Groups and Channels

 

Group

Group

1

17 (R)

 

Reserved

 

2

0

 

Number

String

16

1 – 16 Chars of ‘0’ – ‘9’, ‘*’, ‘#’, ‘,’

 

 

 

 

(Null to query in text)

 

LOCBLDG – Location: Building

This command sets/reports the location of the unit: Building string.

Command Form: DEVICE LOCBLDG [Value]

Argument

Type

Size

Values

Units

Value

String

80

CLEAR = Clear current value

 

 

 

 

1 – 63 Characters

 

 

 

 

(Null to query in text)

 

246

Page 251
Image 251