DIAL – DTMF Dialing

This command dials a DTMF sequence or reports back the last sequence dialed.

Command Form: DEVICE DIAL <Channel> [Number]

Argument

Type

Size

Values

Units

Channel

Channel

1

See Groups and Channels

 

Group

Group

1

17 (R)

 

Reserved

 

2

0

 

Number

String

40

1 – 40 Chars of ‘0’ – ‘9’, ‘*’, ‘#’, ‘,’

 

 

 

 

(Null to query last number dialed in text)

 

DID – Device ID

This command reports the device id. This command is read only except through the front panel.

Command Form: DEVICE DID [Value]

 

 

Argument

Type

Size

Values

Units

Value

Unsigned Integer

4

See Type And Device IDs

 

 

 

 

(Null sent in text, Value returned)

 

DTMFLVL – DTMF Tone Level

This command selects/reports the DTMF tone level.

Command Form: DEVICE DTMFLVL <Channel> [Value]

Argument

Type

Size

Values

Units

Channel

Channel

1

See Groups and Channels

 

Group

Group

1

17 (R)

 

Value

Signed Float

2

-12.00 – 12.00

dB

 

 

 

(Null to query in text)

 

DTONELVL – Dial Tone Level

This command selects/reports the audible dial tone level.

Command Form: DEVICE DTONELVL <Channel> [Value]

Argument

Type

Size

Values

Units

Channel

Channel

1

See Groups and Channels

 

Group

Group

1

17 (R)

 

Value

Signed Float

2

-12.00 – 12.00

dB

 

 

 

(Null to query in text)

 

DUPDATE – Download Update

This command reports the status of download updates.

Command Form: DEVICE DUPDATE [Channel Group Status Percent Done Message]

Argument

Type

Size

Values

Units

Channel

Unsigned Integer

1

 

 

Group

Unsigned Integer

1

 

 

Status

Unsigned Integer

1

(Null to query in text)

 

Percent Done

Unsigned Integer

1

 

 

Message

Char

60

 

 

DVER – Command Dictionary Version

This command reports the version of the command dictionary being used by the unit. This command is read only.

Command Form: DEVICE DVER [Value]

Argument

Type

Size

Values

Units

Value

Unsigned Integer

4

(Sent with a Null in text)

 

237

Page 242