b) Service Menu Chart
Setpoint
Service Menu | Min. | Max. | Unit | Factory Setting | Description |
|
|
|
|
|
|
SP | See r1 | See r2 | °C/°F | 39°F | Cabinet setpoint. |
|
|
|
|
| (compressor off temperature). |
|
|
|
|
| (see r0 for compressor on temperature). |
|
|
|
|
|
|
Thermistor Input (Do Not Adjust)
Service Menu | Min. | Max. | Unit | Factory Setting | Description |
|
|
|
|
|
|
CA1 | 25 | °C/°F | 0 | Cabinet thermistor temperature offset. | |
|
|
|
|
|
|
CA2 | 25 | °C/°F | 0 | Evaporator thermistor temperature | |
|
|
|
|
| offset. |
|
|
|
|
|
|
P1 | 0 | 1 | 0 | Decimal point for °C display: 0=no, | |
|
|
|
|
| 1=yes. |
P2 | 0 | 1 | 1 | Temperature display scale: 0=°C, 1=°F | |
|
|
|
|
|
|
P3 | 0 | 2 | 0 | Evaporator thermistor: | |
|
|
|
|
| 0=not connected |
|
|
|
|
| 1=defrost/evaporator fan |
|
|
|
|
| 2=defrost |
|
|
|
|
|
|
P8 | 0 | 250 | ds | 5 | Temperature display delay. |
|
|
|
|
|
|
Operation (Do Not Adjust)
Service Menu | Min. | Max. | Unit | Factory Setting | Description | |
r0 | 0 | 15 | °C/°F | 4°F | Temperature differential above | |
|
|
|
|
| setpoint for the compressor to | |
|
|
|
|
| turn on. | |
|
|
|
|
|
| |
r1 | r2 | °C/°F | 34°F | Minimum cabinet setpoint. | ||
|
|
|
|
|
| |
r2 | r1 | 99 | °C/°F | 52°F | Maximum cabinet setpoint. | |
|
|
|
|
|
| |
r3 | 0 | 1 | 0 | Locked setpoint. 0=no, 1=yes | ||
r4 | 0 | 99 | °C/°F | 0 | Energy saving and overcooling | |
|
|
|
|
| Do not adjust. | |
r5 | 0 | 99 | °C/°F | 0 | ||
| ||||||
|
|
|
|
|
| |
r6 | 0 | 240 | min. | 30 |
| |
|
|
|
|
|
|
Compressor Protection (Do Not Adjust)
Service Menu | Min. | Max. | Unit | Factory Setting | Description |
|
|
|
|
|
|
C0 | 0 | 240 | min. | 2 | Compressor delay at startup |
|
|
|
|
| and after power interruption. |
|
|
|
|
|
|
C1 | 0 | 240 | min. | 5 | Minimum time between |
|
|
|
|
| compressor starts. |
|
|
|
|
|
|
C2 | 0 | 240 | min. | 3 | Minimum compressor off time. |
|
|
|
|
|
|
C3 | 0 | 240 | sec. | 180 | Minimum compressor run time. |
C4 | 0 | 240 | min. | 10 | Compressor off time with |
|
|
|
|
| defective cabinet thermistor. |
|
|
|
|
|
|
C5 | 0 | 240 | min. | 10 | Compressor on time with |
|
|
|
|
| defective cabinet thermistor. |
|
|
|
|
|
|