B. Sequence of Operation
1. Sequence Cycles and Shutdown
The steps in the sequence are as outlined below. When power is supplied to CB, DM LEDs flash 3 times, then °F LED turns on. Press the power button for 2 sec., the cabinet temperature and EvapFM icon turn on and EvapFM starts.
Note: • EvapFM
•There is a Comp delay of 2 min. at startup.
•There is a minimum Comp run time of 3 min.
•There is a Comp delay of 2 min. after a power interruption.
Cabinet Temperature LEDs | "+" Up | "P" Set | Power |
Button | Button | Button | Button |
°F |
Alarm Icon
Compressor Icon |
| °F LED | |
Defrost Icon | Evaporator Fan Motor Icon | ||
|
a)Refrigerator
•The °F and CT LEDs remain on throughout the sequence of operation.
•This appliance uses a
•
•Cabinet temperature is displayed during defrost.
1. Startup
EvapFM icon is on and Comp icon is flashing. EvapFM energizes.
2. Cool Down
EvapFM icon is on and Comp icon turns steady. EvapFM continues.
3. Cool Down Achieved
EvapFM icon is on. CTh cools to setpoint (default 39°F). EvapFM continues. If Comp run time >