Evaporator Fan Motor (Do Not Adjust)
Service Menu | Min. | Max. | Unit | Factory Setting | Description |
|
|
|
|
|
|
F0 | 0 | 4 | 1 | Fan operation with door closed. | |
|
|
|
|
| Do not adjust. |
|
|
|
|
| 0=off |
|
|
|
|
| 1=on: see also F13, F14, and L10 |
|
|
|
|
| 2=parallel with compressor |
|
|
|
|
| 3= dependent on F1 |
|
|
|
|
| 4=disabled when compressor is off, |
|
|
|
|
| dependent on F1 when |
|
|
|
|
| compressor is on. |
|
|
|
|
|
|
F1 | 99 | °C/°F | 30 | Fan off temperature when F0 set to | |
|
|
|
|
| 3 or 4. Do not adjust. |
|
|
|
|
|
|
F2 | 0 | 2 | 1 | Fan operation during defrost: | |
|
|
|
|
| Do not adjust. |
|
|
|
|
| 0=disabled |
|
|
|
|
| 1=enabled |
|
|
|
|
| 2=dependent on F0 |
F3 | 0 | 15 |
| 2 | Maximum fan off time when defrost |
|
|
|
|
| thermistor used. |
|
|
|
|
|
|
F7 | 99 | °C/°F | 0 | Fan on temperature when defrost | |
|
|
|
|
| thermistor used. |
|
|
|
|
|
|
F8 | 0.1 | 15 | °C/°F | 4 | F1 differential. |
|
|
|
|
|
|
F9 | 0 | 240 | sec. | 0 | Energy saving evaporator fan motor |
|
|
|
|
| delay after compressor shuts off. |
F13 | 0 | 240 | min. | 5 | Energy saving evaporator fan motor |
|
|
|
|
| off time. |
|
|
|
|
|
|
F14 | 0 | 240 | min. | 1 | Energy saving evaporator fan motor |
|
|
|
|
| on time. |
|
|
|
|
|
|
Door Switch and Door Alarm (Do Not Adjust)
Service Menu | Min. | Max. | Unit | Factory Setting | Description |
|
|
|
|
|
|
L0 | 0 | 5 | 2 | Door switch function. | |
|
|
|
|
| 1=compressor and evaporator |
|
|
|
|
| fan motor |
|
|
|
|
| 2=evaporator fan motor |
|
|
|
|
| de‑energized |
|
|
|
|
| |
L1 | 0 | 1 | 0 | Door switch operation. | |
|
|
|
|
| 0=normally open |
|
|
|
|
| 1=normally closed |
|
|
|
|
|
|
L2 | 120 | min. | 10 | Door alarm time delay. | |
|
|
|
|
| |
|
|
|
|
|
|
L3 | 120 | min. | Evaporator fan motor off time | ||
|
|
|
|
| when door is open. |
|
|
|
|
| |
|
|
|
|
|
|
L4 | 0 | 1 | 0 | Save door alarm. | |
|
|
|
|
| 0=no |
|
|
|
|
| 1=yes |
|
|
|
|
|
|
L10 | 0 | 999 | min. | 20 | Energy saving activation. |
|
|
|
|
| After cabinet temperature |
|
|
|
|
| is reached and door switch |
|
|
|
|
| remains closed. |
22