Value | Unsigned Short | 2 | 0 | = 5 |
|
|
| 1 | = 10 |
Default 0 (5)
(Null to query in text)
FEDR – Feedback Elimination Dynamic Node Reset
This command will reset only the dynamic filters on the feedback eliminator. There is no query associated with this command.
Command Form: DEVICE FEDR<Channel> <Group>
Argument | Type | Size | Values | Units |
Channel | Channel | 1 | See GroupAndChannels |
|
Group | Group | 1 | 23 (J) |
|
Reserved | Zero | 2 | Nodes | |
|
|
| (Null to query in text) |
|
FEF – Feedback Elimination Fixed Filter
This command sets the number of fixed filter to use in the feedback eliminator. The fixed filters number will be used during the initialization phase when gain is increased until feedback occurs. A fixed filter will be set at the feedback point during the initialization.
Command Form: DEVICE FEF<Channel> <Group> [Value]
Argument | Type | Size | Values | Units |
Channel | Channel | 1 | See GroupAndChannels |
|
Group | Group | 1 | 23 (J) |
|
Reserved | Unsigned Short | 2 | Zero |
|
FEG – Feedback Elimination Auto Gain Max
This command sets the target gain for auto setup in feedback cancellation.
Command Form: Device FEG<Channel> <Group> [Value]
Argument | Type | Size | Values | Units |
Channel | Channel | 1 | See GroupAndChannels |
|
Group | Group | 1 | 23 (J) |
|
Reserved | Unsigned Short | 2 | 0 - 8 | dB |
|
|
| (Null to query in text) |
|
FEGL – Feedback Elimination Gain Level
This command reports the gain value achieved at the end of the feedback automatic setup. The maximum value possible is set in the FEG command. This is a query only command.
Command Form: Device FEGL<Channel> <Group> [Value]
Argument | Type | Size | Values | Units |
Channel | Channel | 1 | See GroupAndChannels |
|
Group | Group | 1 | 23 (J) |
|
Value | Signed Float | 2 | dB | |
|
|
| (Sent with Null, value returned) |
|
FELD – Feedback Elimination Lock Depth
This command sets the operation of a fixed filter node to be either locked or unlocked. In locked mode, the fixed filter’s depth will remain the same after all the fixed filters are placed. In unlocked mode, the fixed filter’s depth can be modified anytime until the maximum depth is achieved.
Command Form: Device FELD<Channel> <Group> [Value]