ClearOne comm SR 1212, PRO TH20, PRO 8I operation manual 267

Models: SR 1212 PRO 8I PRO TH20

1 320
Download 320 pages 10.06 Kb
Page 272
Image 272

RXBSTEN – Receive Boost Enable

This command selects/reports the receive boost status.

Command Form: DEVICE RXBSTEN <Channel> [Value]

Argument

Type

Size

Values

Units

Channel

Channel

1

See Groups and Channels

 

Group

Group

1

17 (R)

 

Value

Unsigned Integer

2

0

= Off

 

 

 

 

1

= On

 

 

 

 

2

= Toggle

 

 

 

 

(Null to query in text)

 

SERECHO – Serial Echo

This command selects/reports the serial echo of the RS-232 port.

Command Form: DEVICE SERECHO [Value]

Argument

Type

Size

Values

Units

Value

Unsigned Integer

4

0

= Off

 

 

 

 

1

= On

 

 

 

 

2

= Toggle

 

 

 

 

(Null to query in text)

 

NOTE: The unit will return the updated state of the last selection in the same form as the command.

SFTYMUTE – Safety Mute

This command selects/reports the state of the safety mute. Safety mute holds all outputs in a muted state. It used for syncing to a site document to avoid feedback or blown speakers until the unit is in a settled state.

Command Form: DEVICE SFTYMUTE [Value]

Argument

Type

Size

Values

Units

Value

Channel

4

0

= off

 

 

 

 

1

= on

 

 

 

 

2

= toggle

 

 

 

 

(Null to query in text)

 

SIGGEN – Signal Generator

This command selects/reports of the signal generator activation.

Command Form: DEVICE SIGGEN [Channel Group Type Amplitude Frequency]

Argument

Type

Size

Values

 

Units

Channel

Channel

1

See Groups and Channels

 

 

 

 

(Null to query in text)

 

Group

Group

1

1, 3, 7 (I, M, L)

 

 

Type

Unsigned Integer

2

1

= Pink Noise

 

 

 

 

2

= White Noise

 

 

 

 

3

= Tone

 

 

Amplitude

Signed Float

4

-60.00 – 20.00

 

dB

Frequency

Unsigned Float

4

Type 1 – 2

0 (Null in text)

Hz

 

 

 

Type 3

20.00 – 20000.00

 

SIGGENEN – Signal Generator Enable

This command selects/reports of the signal generator activation.

Command Form: DEVICE SIGGENEN [Value]

Argument

Type

Size

Values

Units

Value

Unsigned Integer

4

0

= Off

 

 

 

 

1

= On

 

 

 

 

2

= Toggle

 

 

 

 

(Null to query in text)

 

267