MTRXLVL – Matrix Attenuation Adjust
This command selects/reports the matrix level at the cross point.
Command Form:
DEVICE MTRXLVL <Src. Ch.> <Src. Gp.> <Dest. Ch.> <Dest. Gp.> [Value] [A/R]
Argument | Type | Size | Values | Units |
Source Channel | Channel | 1 | See Groups and Channels |
|
Source Group | Group | 1 | 1, 3, 5, 6, 7, 12, 17 |
|
|
|
| (I, M, P, E, L, F, R) |
|
Destination Channel | Channel | 1 | See Groups and Channels |
|
Destination Group | Group | 1 | 2, 5, 6, 12, 16, |
|
|
|
| (H, J, O, P, E, F, T,) |
|
Value | Signed Float | 4 | dB | |
|
|
| (Null to query in text) |
|
Absol / Rel |
| 0 | A = Absolute |
|
|
|
| R = Relative |
|
|
|
| Null = Relative |
|
NOTE: Values indicate entry range only. Actual internal range of the matrix attenuation is from
MUTE – Mute
This command selects/reports the setting of mute on a channel.
Command Form: DEVICE MUTE <Channel> <Group> [Value]
Argument | Type | Size | Values | Units | |
Channel | Channel | 1 | See Groups and Channels |
| |
Group | Group | 1 | 1, 2, 3, 5, 7, 12, 16, 17 (I, J, O, M, P, L, F, T, R) |
| |
Value | Unsigned Integer | 2 | 0 | = Off |
|
|
|
| 1 | = On |
|
|
|
| 2 | = Toggle |
|
|
|
| (Null to query in text) |
|
NAME – Unit Name (NETBIOS Name)
This command sets/reports the name of the unit which is also used for its NETBIOS name.
Command Form: DEVICE NAME [Value]
Argument | Type | Size | Values | Units |
Value | String | 16 | 1 – 15 Characters |
|
|
|
| (Null to query in text) |
|
NCD – Noise Cancellation Depth Adjust
This command selects/reports the depth setting of the Noise Cancellation.
Command Form: DEVICE NCD <Channel> <Group> [Value]
Argument | Type | Size | Values | Units |
Channel | Channel | 1 | See Groups and Channels |
|
Group | Group | 1 | 3, 17 (M, R) |
|
Value | Unsigned Integer | 2 | 6 – 15 | dB |
|
|
| (Null to query in text) |
|