G.LED Bar Meter: Displays the audio level of a selected input, output, processing, or fader channel. Default

meters: 880-Output 12, 880T-Output 12 , 840T-Output 8, 8i-Mic 1, TH20-Telco Tx, SR1212-Output 12.

AMP Fault Indicator LEDs(880TA, SR 1212A): Indicates amplifier faults: »» 1-4 indicates clip

»» 5 indicates thermal overload »» 6 indicates fault

»» 7 indicates fan on/off

H.Amplifier On/Off Switch (880TA, SR 1212A): Turns power to the amplifiers on or off.

NOTE (880TA, SR 1212A): This does NOT disconnect power from the AC mains. To disconnect unit power from the mains, disconnect the unit’s power cord from the mains socket. To reconnect power, plug the unit’s power cord into the mains socket following all safety instructions and guidelines.

I.Telco On/Off Button & LEDs: The button connects/disconnects the telephone line attached to the device and the LEDs indicate the connection status of the attached telephone line (840T, TH20, 880T, 880TA).