PAFLT – PA Fault
This indicates one of the power amplifier channels is in a FAULT condition. This is
Command Form: DEVICE PAEQEN [Bitmap]
Argument | Type | Size Values |
Bitmap | Hexadecimal Integer | 4 |
PAIMPED – PA Output Impedance
This command selects the output impedance for the PA channel to be either 8 ohms or 70/100V. Command Form: DEVICE PIAMPED <Channel> <Group> [Value]
Argument | Type | Size | Values | Units | |
Channel | Channel | 1 | See Groups and Channels |
| |
Group | Group | 1 | 23 (J) |
| |
Value | Unsigned | 2 | 0 | = 8 ohms |
|
| Short |
| 1 | = 70/100V |
|
(Null to query in text)
PALEN – PA Limiter Enable
This command changes enables the Limiter on a power amplifier channel.
Command Form: DEVICE PALEN <Channel> <Group> [Value]
Argument | Type | Size | Values | Units | |
Channel | Channel | 1 | See Groups and Channels |
| |
Group | Group | 1 | 23 (J) |
| |
Value | Unsigned Short | 2 | 0 | = Off |
|
|
|
| 1 | = On |
|
|
|
| 2 | = Toggle |
|
|
|
| (Null to query in text) |
|
PALT – PA Limiter Threshold
This command sets the Limiter threshold on a power amplifier channel.
Command Form: DEVICE PALT <Channel> <Group> [Value]
Argument | Type | Size | Values | Units |
Channel | Channel | 1 | See Groups and Channels |
|
Group | Group | 1 | 23 (J) |
|
Value | Signed Float | 2 | dB | |
|
|
| (Null to query in text) |
|