BAUD – Baud Rate

This command selects/reports the baud rate of the serial port.

Command Form: DEVICE BAUD [Value]

Argument

Type

Size

Values

Units

Value

Unsigned Integer

4

9600, 19200, 38400, 57600, 115200

 

 

 

 

(Null to query in text)

 

CALLDUR – Call Duration

This command returns current call duration. If no call is active, this command returns 0. At the time of call termination, this command will automatically be sent out to report call duration. This command is read only.

Command Form: DEVICE CALLDUR <Channel> <Duration>

Argument

Type

Size

Values

Units

Channel

Channel

1

See Groups and Channels

 

Group

Group

1

17 (R)

 

Reserved

 

2

0

 

Duration

String

8

String of format HR:MN:SS

 

CALLERID – Reports Caller ID Information

This command reports Caller Identification Information. This command is reportable only. It cannot be queried or set.

Command Form: DEVICE CALLERID <Channel> <Number> <Argument>

Argument

Type

Size

Values

Units

Channel

Channel

1

See Groups and Channels

 

Group

Group

1

17 (R)

 

Reserved

Unsigned Integer

2

0

 

Number

String

16

1 – 16 chars

 

Label

String

16

1 – 16 chars

 

CGROUP – Compressor Group Select

This command selects/reports the setting of the compressor group.

Command Form: DEVICE CGROUP <Channel> [Value]

Argument

Type

Size

Values

Units

Channel

Channel

1

See Groups and Channels

 

Group

Group

1

5

(P)

 

Value

Unsigned Integer

2

0

= none

Compressor

 

 

 

1

– 4

Group

 

 

 

(Null to query in text)

 

CHAIRO – Chairman Override Mode

This command selects/reports the setting of chairman override.

Command Form: DEVICE CHAIRO <Channel> [Value]

Argument

Type

Size

Values

Units

Channel

Channel

1

See Groups and Channels

 

Group

Group

1

3

(M)

 

Value

Unsigned Integer

2

0

= Off

 

 

 

 

1

= On

 

 

 

 

2

= Toggle

 

 

 

 

(Null to query in text)

 

232

Page 237
Image 237