Reserved | Unsigned Integer | 2 | 0 |
Label | String | 12 | 1 – 12 characters |
|
|
| CLEAR = clear the label |
|
|
| (Null to query in text) |
DEVICESUBTYPE – Sets the Subtype of a Connected Device
This command enables/disables or reports the current type of device connected to an input or output. Command Form: DEVICE DEVICESUBTYPE <Channel> <Group> [Value]
Argument | Type | Size | Values | Units |
Channel | Channel | 1 | See Groups and Channels |
|
Group | Group | 1 | 1, 2, 3, 7 (I, O, M, L) |
|
Value | Unsigned Integer | 2 | (NULL to query in text) |
|
DEVICETYPE – Sets the Type of a Connected Device
This command enables / disables or reports the current type of device connected to an input or output. Command Form: DEVICE DEVICETYPE <Channel> <Group> [Value]
Argument | Type | Size | Values | Units |
Channel | Channel | 1 | See Groups and Channels |
|
Group | Group | 1 | 1, 2, 3, 7 (I, O, M, L) |
|
Value | Unsigned Integer | 2 | (NULL to query in text) |
|
DFLTM – Default Meter
This command selects/reports the setting of the default meter on the front panel.
Command Form: DEVICE DFLTM [Channel Group Position]
Argument | Type | Size | Values | Units |
Channel | Channel | 1 | See Groups and Channels |
|
|
|
| (Null to query in text) |
|
Group | Group | 1 | 1, 2, 3, 7, 16, 17 (I, O, M, L, T, R) |
|
Position | Meter Type | 2 | 1 – 4, as applicable for group |
|
|
|
| See Meter Type Definitions |
|
Diag – Diagnostic Commands
This command is used to return status and diagnostic information. It is intended to be used as a text command only.
This is a query only command.
Command Form: DEVICE DIAG <Channel> <Group> [Value]
Argument | Type | Size | Values | Units | |
Channel | Channel | 1 | See Groups and Channels |
| |
Group | Group | 1 | 23 | (J) |
|
Value | Unsigned | 2 | 0 = List of current commands |
| |
| Short |
| (J) Power Amp |
| |
|
|
| 1 | = Fan/Temp |
|
|
|
| 2 | = Noise Gate |
|
|
|
| 3 | = Feedback Nodes |
|
Information | String | 80 | Diagnostic String |
| |
|
|
| (ALWAYS NULL IN TEXT) |
|