value unsigned short 2 0 = standard
1 = Custom
(null to query in text)
RINGOFF – Ring Cadence Off Time
this command sets the ring cadence off time. the country code should be set first using the Country
command.
Command Form: DEVICE RINGOFF <Channel> <group> [value]
Argument Type Size Values units
Channel Channel 1 see Groups and Channels
group group 1 17 (r)
value unsigned short 2 0 = 80
1 = 128
2 = 256
3 = 384
4 = 512
5 = 640
6 = 768
7 = 896
8 = 1024
(null to query in text)
ms
RINGON – Ring Cadence On Time
this command sets the ring cadence on time. the country code should be set first using the Country
command.
Command Form: DEVICE RINGON <Channel> <group> [value]
Argument Type Size Values units
Channel Channel 1 see Groups and Channels
group group 1 17 (r)
value unsigned short 2 0 = 100
1 = 150
2 = 200
3 = 256
4 = 384
5 = 512
6 = 640
7 = 1024
(null to query in text)
ms
RxBOOST – Receive Boost
this command selects/reports the receive boost status.
Command Form: DEVICE RxBOOST <Channel> [value]
Argument Type Size Values units
Channel Channel 1 see Groups and Channels
group group 1 17 (r)
value unsigned Integer 2 0, 3, 6, 9, or 12
(null to query in text)