Value

Unsigned Short

2

0

= Standard

 

 

 

1

= Custom

(Null to query in text)

RINGOFF – Ring Cadence Off Time

This command sets the ring cadence off time. The country code should be set first using the COUNTRY command.

Command Form: DEVICE RINGOFF <Channel> <Group> [Value]

Argument

Type

Size

Values

Units

Channel

Channel

1

See Groups and Channels

 

Group

Group

1

17 (R)

 

Value

Unsigned Short

2

0 = 80

ms

 

 

 

1

= 128

 

 

 

 

2

= 256

 

 

 

 

3

= 384

 

 

 

 

4

= 512

 

 

 

 

5

= 640

 

 

 

 

6

= 768

 

 

 

 

7

= 896

 

 

 

 

8

= 1024

 

 

 

 

(Null to query in text)

 

RINGON – Ring Cadence On Time

This command sets the ring cadence on time. The country code should be set first using the COUNTRY command.

Command Form: DEVICE RINGON <Channel> <Group> [Value]

Argument

Type

Size

Values

Units

Channel

Channel

1

See Groups and Channels

 

Group

Group

1

17 (R)

 

Value

Unsigned Short

2

0 = 100

ms

 

 

 

1

= 150

 

 

 

 

2

= 200

 

 

 

 

3

= 256

 

 

 

 

4

= 384

 

 

 

 

5

= 512

 

 

 

 

6

= 640

 

 

 

 

7

= 1024

 

 

 

 

(Null to query in text)

 

RXBOOST – Receive Boost

This command selects/reports the receive boost status.

Command Form: DEVICE RXBOOST <Channel> [Value]

Argument

Type

Size

Values

Units

Channel

Channel

1

See Groups and Channels

 

Group

Group

1

17 (R)

 

Value

Unsigned Integer

2

0, 3, 6, 9, or 12

dB

 

 

 

(Null to query in text)

 

266

Page 271
Image 271
ClearOne comm PRO 8I, PRO TH20 Ringoff Ring Cadence Off Time, Ringon Ring Cadence On Time, Rxboost Receive Boost, 266