Value | Unsigned Short | 2 | 0 | = Standard |
|
|
| 1 | = Custom |
(Null to query in text)
RINGOFF – Ring Cadence Off Time
This command sets the ring cadence off time. The country code should be set first using the COUNTRY command.
Command Form: DEVICE RINGOFF <Channel> <Group> [Value]
Argument | Type | Size | Values | Units | |
Channel | Channel | 1 | See Groups and Channels |
| |
Group | Group | 1 | 17 (R) |
| |
Value | Unsigned Short | 2 | 0 = 80 | ms | |
|
|
| 1 | = 128 |
|
|
|
| 2 | = 256 |
|
|
|
| 3 | = 384 |
|
|
|
| 4 | = 512 |
|
|
|
| 5 | = 640 |
|
|
|
| 6 | = 768 |
|
|
|
| 7 | = 896 |
|
|
|
| 8 | = 1024 |
|
|
|
| (Null to query in text) |
|
RINGON – Ring Cadence On Time
This command sets the ring cadence on time. The country code should be set first using the COUNTRY command.
Command Form: DEVICE RINGON <Channel> <Group> [Value]
Argument | Type | Size | Values | Units | |
Channel | Channel | 1 | See Groups and Channels |
| |
Group | Group | 1 | 17 (R) |
| |
Value | Unsigned Short | 2 | 0 = 100 | ms | |
|
|
| 1 | = 150 |
|
|
|
| 2 | = 200 |
|
|
|
| 3 | = 256 |
|
|
|
| 4 | = 384 |
|
|
|
| 5 | = 512 |
|
|
|
| 6 | = 640 |
|
|
|
| 7 | = 1024 |
|
|
|
| (Null to query in text) |
|
RXBOOST – Receive Boost
This command selects/reports the receive boost status.
Command Form: DEVICE RXBOOST <Channel> [Value]
Argument | Type | Size | Values | Units |
Channel | Channel | 1 | See Groups and Channels |
|
Group | Group | 1 | 17 (R) |
|
Value | Unsigned Integer | 2 | 0, 3, 6, 9, or 12 | dB |
|
|
| (Null to query in text) |
|