AGCSET – Automatic Gain Control Adjust

This command selects/reports the settings of the Automatic Gain Control.

Command Form: DEVICE AGCSET <Channel> <Group> [Threshold Target Attack Gain]

 

Argument

Type

Size

Values

Units

Channel

Channel

1

See Groups and Channels

 

Group

Group

1

1, 3, 7 (I, M, L)

 

Threshold

Signed Integer

1

-50 – 0

dB

 

 

 

(Null to query in text)

 

Target

Signed Integer

1

-30 – 20

dB

Response

Unsigned Float

2

0.10 – 10.00

S

Time

 

 

 

 

Gain

Unsigned Float

2

0.00 – 18.00

dB

AMBLVL – Ambient Level Adjust

This command selects/reports the ambient level.

Command Form: DEVICE AMBLVL <Channel> [Value]

Argument

Type

Size

Values

Units

Channel

Channel

1

See Groups and Channels

 

Group

Group

1

3 (M)

 

Value

Signed Float

2

-80.00 – 0.00

dB

 

 

 

(Null to query in text)

 

AMXDUET – Use AMX Duet Discovery

This command sets and reports the status of AMX Duet Discovery.

Command Form: DEVICE AMXDUET [Value]

 

 

Argument

Type

Size

Values

Units

Value

Unsigned Integer

4

0

= Off

 

 

 

 

1

= On

 

 

 

 

2

= toggle

 

 

 

 

(Null to query in text)

 

AUDIOMASTER – Expansion Bus Audio Master Mode

This command reports the mode of the unit for control of the expansion bus audio.

Command Form: DEVICE AUDIOMASTER [Value]

Argument

Type

Size

Values

Units

Value

Unsigned Integer

4

1

= Master

 

 

 

 

2

= Slave

 

 

 

 

(Null to query in text)

 

AV – Adaptive Volume

This command enables/disables adaptive volume tracking on a power amplifier channel. Command Form: DEVICE AV <Channel> <Group> [Value]

Argument

Type

Size

Values

Units

Channel

Channel

1

See Groups and Channels

 

Group

Group

1

23 (J)

 

Value

Signed Float

2

0

= Off

 

 

 

 

1

= On

 

 

 

 

2

= Toggle

 

(Null to query in text)

230

Page 235
Image 235
ClearOne comm PRO 8I, PRO TH20, SR 1212 operation manual 230