230AGCSET – Automatic Gain Control Adjust
this command selects/reports the settings of the automatic gain Control.
Command Form: DEVICE AGCSET <Channel> <group> [threshold target attack gain]
Argument Type Size Values units
Channel Channel 1 see Groups and Channels
group group 1 1, 3, 7 (I, m, l)
threshold signed Integer 1 -50 – 0
(null to query in text)
dB
target signed Integer 1 -30 – 20 dB
response
time
unsigned Float 2 0.10 – 10.00 s
gain unsigned Float 2 0.00 – 18.00 dB
AmBLVL – Ambient Level Adjust
this command selects/reports the ambient level.
Command Form: DEVICE AmBLVL <Channel> [value]
Argument Type Size Values units
Channel Channel 1 see Groups and Channels
group group 1 3 (m)
value signed Float 2 -80.00 – 0.00
(null to query in text)
dB
AmxduET – Use AMX Duet Discovery
this command sets and reports the status of amx Duet Discovery.
Command Form: DEVICE AmxduET [value]
Argument Type Size Values units
value unsigned Integer 4 0 = off
1 = on
2 = toggle
(null to query in text)
AudIOmASTER – Expansion Bus Audio Master Mode
this command reports the mode of the unit for control of the expansion bus audio.
Command Form: DEVICE AudIOmASTER [value]
Argument Type Size Values units
value unsigned Integer 4 1 = master
2 = slave
(null to query in text)
AV – Adaptive Volume
this command enables/disables adaptive volume tracking on a power amplifier channel.
Command Form: DEVICE AV <Channel> <group> [value]
Argument Type Size Values units
Channel Channel 1 see Groups and Channels
group group 1 23 (J)
value signed Float 2 0 = off
1 = on
2 = toggle
(null to query in text)