MAX – Maximum Gain Setting

This command changes or reports back the maximum gain setting for an input, output or assignable processing block.

Command Form: DEVICE MAX <Channel> <Group> [Value]

Argument

Type

Size

Values

Units

Channel

Channel

1

See Groups and Channels

 

Group

Group

1

1, 2, 3, 5, 7, 12, 16, 17 (I, O, M, P, L, F, T, R)

 

Value

Signed Float

2

-65.00 – 20.00

dB

 

 

 

(Null to query in text)

 

MC Multi-Channel Mode

This command groups audio controls for channels. Audio Controls include Gain, Ramp Gain, and Mute. Command Form: DEVICE MC <Channel> <Group> [Value]

Argument

Type

Size

Values

Channel

Channel

1

1 – n (Max number of channels in Multi-Channel Group divided by 2)

Group

Group

1

128 (No text group)

Multi-

Group

2

Only 23 (J) accepted for now.

Channel

 

 

See GroupAndChannels

Group

 

 

 

Bitmap

Hexadecimal

4

 

 

Integer

 

 

MCGAIN Multi-Channel Gain

This command that groups adjusts/reports audio gain of the grouped channels.

Command Form: DEVICE MCGAIN <Channel> <Group> [Value] [Absol/Rel]

 

Argument

Type

Size

Values

Units

Channel

Channel

1

1 – n (Max number of channels in Multi-Channel

 

 

 

 

Group divided by 2)

 

Group

Group

1

128 (No text group)

 

Multi-

Unsigned

2

Only 23 (J) accepted for now.

 

Channel

Integer

 

See GroupAndChannels

 

Group

 

 

 

 

Value

String

4

-99.90 – 99.90

dB

 

 

 

(Null to query in text)

 

Absol./

 

0

A = Absolute

 

Rel.

 

 

R = Relative

 

 

 

 

Null = Relative

 

250

Page 255
Image 255
ClearOne comm PRO TH20, PRO 8I, SR 1212 operation manual MC Multi-Channel Mode, Mcgain Multi-Channel Gain, 250