White Rodgers PS9, FL9S, FC9S service manual Description

Page 9

127237-UUM-A-0605

ITEM

DESCRIPTION

MOTOR

 

1

MOTOR,DIRECT DRIVE BLOWER

2

MOTOR, INDUCER ASS’Y

ELECTRICAL

3

CAPACITOR, RUN

4

SWITCH, LIMIT (INDUCER)

5

LIMIT, TEMPERATURE (Primary)

6

LIMIT, FLAME ROLL-OUT

7

CONTROL, FURNACE MODULE

8

FUSE

9

IGNITER

10

SENSOR, FLAME

11

SWITCH, PRESSURE

12

SWITCH, DOOR

13

TRANSFORMER

14

VALVE, GAS

AIR MOVING

15

HOUSING, BLOWER

16

WHEEL, BLOWER

FABRICATED PARTS

17

PANEL, BLOWER COVER

18

BRACKET, CONDENSATE TRAP

19

BURNER, MAIN GAS

20

COIL, CONDENSING

21

SHELF, BLOWER

22

HEAT EXCHANGER ASS’Y

23

MANIFOLD, GAS

24

SHIELD, PAN

25

PAN, CONDENSATE

26

PANEL, VEST ACCESS

27

PANEL, BLOWER ACCESS

28

WRAPPER, BURNER BOX

29

CHANNEL, TOE PLATE

30

COVER, GAS CONTROL

31

PANEL, BOTTOM

32

PANEL, TOP

33

SUPPORT, BURNER

34

WRAPPER, CABINET

35

BRACKET, FILTER

36

PLATE, DIFFUSER

37

BRACKET, IGNITER

38

BRACKET, DOOR SWITCH

39

BRACKET, DOOR

40

BOTTOM PANEL, BURNER BOX

41

TOP MOUNTING BRACKET

42

BOTTOM MOUNTING BRACKET

NOTE: *Not Shown

ITEM

DESCRIPTION

MISCELLANEOUS

43

PLUG, WINDOW, CLEAR - 1.5”

44

COMBUSTION AIR TRANSITION, 3-WAY

45

TUBING, SILICONE (Gray, .188 ID, 2.83 ft. req’d)

46

TUBING, SILICONE (Preformed)

47

TUBING, SILICONE (Gray, .188 ID, 1.25 ft. req’d)

48

GASKET, COMBUSTION BLOWER

49

GASKET, CONDENSATE PAN

50

GASKET, UPPER CONDENSATE PAN (2 Req’d)

51

GASKET, GAS CONTROLS

52

GASKET, CONDENSING COIL

53

GASKET, COMBUSTION AIR TRANSITION

54

 

55

VENT PIPE 2” X 15.25” LG.

56

GROMMET, MOTOR (3 Req’d)

57

FERRULE (3 Req’d)

58

COMBUSTION BLWR RESTRICTOR

59

 

60

RETAINER, SQUARE

61

RESTRICTOR, TUBE

62

WASHER, FLAT FIBERGLASS (2 Req’d)

63

 

64

HARNESS, MAIN WIRING

65

MOUNT, 1 PC. MOTOR

66

ORIFICE, BURNER (Natural #45)

67

TRAP, CONDENSATE

68

WIRING DIAGRAM

69

45 DEG. STREET ELBOW 2”

70

DRAIN TUBE, CONDENSATE TRAP

71

DRAIN TUBE, COMBUSTION BLOWER

72

DRAIN TUBE, CONDENSATE PAN

73

DRAIN TUBE, STRAIGHT 21” LG.

74

DRAIN TUBE, RAIN GUTTER

75

DRAIN HOSE ASSEMBLY

76

DRAIN TUBE, CONDENSATE

77

LOCKNUT, CONDUIT (1/2”)

78

ADAPTER, INSERT

79

BUSHING, THREADED

80

FILTER, AIR (2 Req’d) (20 x 14 x .75)

81

BAFFLE, BURNER BOX

82

GROMMET, MANIFOLD

83

 

84

DRAIN TUBE, VENT PIPE

85

DOOR KNOB (Black)

86

RETAINER, DOOR KNOB

87

NUT, SELF-THREADING

88

SIGHT GLASS, OVAL

Major components and suggested stocking items are shown with shaded item number.

Unitary Products Group

9

Image 9
Contents Safety Table of ContentsSection I USER’S Information Contact InformationInstructions for Examining the Furnace To Turn Off the Appliance HOW Your GAS Furnace WorksSTART-UP and Shutdown Instructions Operating InstructionsBlower Care Furnace User MaintenanceAir Filters Removing FiltersSafety Section Section II Service and Maintenance ManualFurnace Maintenance Section Sequence of OperationFurnace Cleaning Section TroubleshootingFurnace Control Diagnostics Furnace Control Event Schedule Diagnostic Fault Code Storage and RetrievalSection III Replacement Parts List Description Model no Description Used with Field Installed Accessories NON-ELECTRICALWiring Diagram Section IV Wiring DiagramUnitary 5005 Norman Products York Group Drive 73069 Exclusions

FC9S, PS9, FL9S specifications

White Rodgers is a renowned name in the HVAC industry, and their line of gas control units, including the PS9, FC9S, and FL9S models, exemplifies innovation and reliability. These products are designed to offer precise gas control for a wide range of heating applications, making them essential components in modern heating systems.

The White Rodgers PS9 is an integrated gas valve that combines multiple functionalities into a single unit. This model features a compact design that allows it to fit into tight spaces while still providing alignment with various burner types. The PS9 incorporates a user-friendly wiring connection system, facilitating easier installation and maintenance. With its adjustable pressure settings, this model can optimize performance in diverse heating scenarios, ensuring users can enjoy efficient and effective temperature control.

The FC9S model enhances user experience with its advanced safety features. It is equipped with a built-in safety switch that cuts off gas supply in the event of a malfunction. Additionally, the FC9S features a self-diagnostic capability, which allows it to detect system faults and provide feedback for more straightforward troubleshooting. This feature not only improves operational safety but also minimizes downtime in heating systems.

The FL9S model stands out for its versatility and adaptability. Designed for a variety of applications, the FL9S works efficiently in both residential and commercial settings. It supports multiple gas types, including natural gas and propane, making it a flexible choice for users with different heating needs. Like its counterparts, the FL9S also features robust construction to withstand varying environmental conditions, ensuring longevity and reliability in heat applications.

Across these models, White Rodgers utilizes high-quality materials and state-of-the-art manufacturing processes. Each unit is subjected to rigorous testing to ensure it meets industry standards for safety and efficiency. Moreover, the incorporation of energy-saving technologies in these gas valves aligns with growing environmental considerations, making them an excellent investment for those looking to enhance their heating systems.

In conclusion, the White Rodgers PS9, FC9S, and FL9S models represent cutting-edge technology in gas control solutions, providing essential features for reliability, safety, and efficiency in heating applications. Whether for residential or commercial use, these units are engineered to meet the demands of modern heating, making them a trusted choice for HVAC professionals and homeowners alike.