Whirlpool 315422-000, W10123251, SG1J5040T3NOV 7K Location Requirements, Site Location

Page 4

WARNING

 

 

 

Flammable Vapors

FLAMMABLES

FIRE AND EXPLOSION HAZARD Can result in serious injury or death

Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. Storage of or use of gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance can result in serious injury or death.

Read and follow water heater warnings and instructions.

4

Location Requirements

WARNING

Carbon Monoxide Poisoning Hazard Do not install in a mobile home.

Doing so can result in death or carbon monoxide poisoning.

The Flame Lock™Safety System is designed to reduce the risk of flammable vapor-related fires. The patented system protects your family by trapping the burning vapors within the water heater combustion chamber through the special flame-trap. The burning vapors literally “burn themselves out” without escaping back into the room. In the event

of a flammable vapor incident, the Flame Lock™Safety System disables the water heater by shutting off the gas supply to the water heater’s burner and pilot, preventing re-ignition of any remaining flammable vapors in the area. This will not prevent a possible fire/explosion if the igniter is depressed and flammable vapors have accumulated in the combustion chamber with the pilot light off. If you suspect a flammable vapor incident has occurred, do not use this appliance. Do not attempt to light this appliance, or depress the igniter button if you suspect flammable vapors have accumulated inside or outside the appliance. Immediately call a qualified person to inspect the appliance. Water heaters subjected to a flammable vapors incident will show a discoloration on the flame-trap and require replacement of the entire water heater.

Do not use or store flammable products such as gasoline, solvents, or adhesives in the same room or area near the water heater. If such flammables must be used, all gas burning appliances in the vicinity must be shut off and their pilot lights extinguished. Open the doors and windows for ventilation while flammable substances are in use.

If flammable liquids or vapors have spilled or leaked in the area of the water heater, leave the area immediately and call the fire department from a neighbor’s home. Do not attempt to clean the spill until all ignition sources have been extinguished.

Keep combustibles such as boxes, magazines, clothes, etc. away from the water heater area.

Site Location

Select a location near the center of the water piping system. The water heater must be installed indoors and in a vertical position on a level surface. Do not install in bathrooms, bedrooms, or any occupied room normally kept closed.

Locate the water heater as close to the chimney or gas vent as practical. Consider the vent system piping and combustion air supply requirements when selecting the water heater location. The venting system must be able to run from the water heater to termination with minimal length and elbows.

Locate the water heater near the existing gas piping. If installing a new gas line, locate the water heater to minimize the pipe length and elbows.

NOTE: This water heater must be installed according to all local and state codes or, in the absence of local and state codes, the “National Fuel Gas Code”, ANSI Z223.1(NFPA 54)-latest edition.

Image 4
Contents Installation Instructions Use & Care Guide Water Heater Safety Table Of ContentsInstalling Your GAS Water Heater Important Information About This Water HeaterConsumer Information Consumer ResponsibilitiesLocation Requirements Site LocationClearances and Accessibility Gas Pressure Testing Gas SupplyGas Requirements Gas PressureCombustion Air Supply and Ventilation Natural Gas Pipe Capacity Table Cu. Ft./HrConfined Space Unconfined SpaceAll Air from Inside the Building All Air from Outdoors Louvers and GrillesDraft hood Installation Vent ConnectorsVent Pipe System Vent Pipe SizeChimney Connection Vertical Exhaust Gas VentPiping Installation Water System PipingClosed System/Thermal Expansion Temperature and Pressure Relief Valve Relief Valve and Pipe Insulation Some ModelsSpecial Applications Solar InstallationCombination Space Heating/Potable Water System Installation Checklist Operating Your Water Heater Lighting InstructionsChecking the Draft Burn Hazard Do not touch vent Doing so can result in burnsWater Temperature Regulation Burner FlamesStacking Emergency Shut DownOperational Conditions Routine Preventive Maintenance Maintenance of Your Water HeaterDraining and Flushing Replacement Parts Removing the Burner Door AssemblyReplacing the Pilot Assembly Natural Gas Burner Ultra Low NoxCleaning the Pilot Assembly External Inspection & Cleaning of the Flame-trapCleaning the Combustion Chamber and Flame-trap Replacing the ThermocoupleTesting the Igniter System Replacing the Burner Door AssemblyPiezoelectric Igniter System Flame LockSafety System Operational Checklist Removing and Replacing the Gas Control Valve/ThermostatSlow HOT Water Pilot Light Troubleshooting Chart Repair Parts Illustration Repair Parts ListListed Parts Kits and Illustrations Page