Whirlpool SG1J4040T3NOV 7K, 315422-000 Installing Your GAS Water Heater, Consumer Information

Page 3

INSTALLING YOUR GAS WATER HEATER

Important Information About This Water Heater

This gas water heater was manufactured to voluntary safety standards to reduce the likelihood of a flammable vapor ignition incident. New technology used in meeting these standards makes this product more sensitive to installation errors or improper installation environments. Please review the Installation Checklist found at the end of the installation instructions section and make any required installation upgrades or changes.

Consumer Information

This water heater is design-certified by CSA International as a Category I, non-direct vented water heater which takes its combustion air either from the installation area or from air ducted to the unit from the outside.

This water heater must be installed according to all local and state codes or, in the absence of local and state codes, the “National Fuel Gas Code”, ANSI Z223.1(NFPA 54)- latest edition. This is available from the following:

CSA America, Inc.

8501 East Pleasant Valley Road Cleveland, OH 44131

National Fire Protection Association 1 Batterymarch Park

Quincy, MA 02269

Check your phone listings for the local authorities having jurisdiction over your installation.

Consumer Responsibilities

This manual has been prepared to acquaint you with the installation, operation, and maintenance of your gas water heater and provide important safety information in these areas.

Read all of the instructions thoroughly before attempting the installation or operation of this water heater.

Do not discard this manual. You or future users of this water heater will need it for future reference.

Service to the Flame Lock™Safety System should only be performed by a qualified person.

Examples of a qualified person include: licensed plumbers, authorized gas company personnel, and authorized service personnel.

IMPORTANT: The manufacturer and seller of this water heater will not be liable for any damages, injuries, or deaths caused by failure to comply with the installation and operating instructions outlined in this manual.

If you lack the necessary skills required to properly install this water heater, or you have difficulty following the instructions, you should not proceed but have a qualified person perform the installation of this water heater. Massachusetts code requires this water heater to be

installed in accordance with Massachusetts Plumbing and Fuel Gas Code 248 CMR Section 2.00 and 5.00.

A data plate identifying your water heater can be found next to the gas control valve/thermostat. When referring to your water heater, always have the information listed on the data plate readily available.

Retain your original receipt as proof of purchase.

Unpacking the Water Heater

WARNING

Excessive Weight Hazard

Use two or more people to move and install water heater.

Failure to do so can result in back or other injury.

Removing Packaging Materials

IMPORTANT: Do not remove any permanent instructions, labels, or the data label from either the outside of the water heater or on the inside of water heater panels.

Remove exterior packaging and place installation components aside.

Inspect all parts for damage prior to installation and start-up.

Completely read all instructions before attempting to assemble and install this product.

After installation, dispose of/recycle all packaging materials.

3

Image 3
Contents Installation Instructions Use & Care Guide Table Of Contents Water Heater SafetyConsumer Responsibilities Installing Your GAS Water HeaterImportant Information About This Water Heater Consumer InformationSite Location Location RequirementsClearances and Accessibility Gas Pressure Gas Pressure TestingGas Supply Gas RequirementsNatural Gas Pipe Capacity Table Cu. Ft./Hr Combustion Air Supply and VentilationUnconfined Space Confined SpaceAll Air from Inside the Building Louvers and Grilles All Air from OutdoorsVent Pipe Size Draft hood InstallationVent Connectors Vent Pipe SystemVertical Exhaust Gas Vent Chimney ConnectionWater System Piping Piping InstallationClosed System/Thermal Expansion Relief Valve and Pipe Insulation Some Models Temperature and Pressure Relief ValveSolar Installation Special ApplicationsCombination Space Heating/Potable Water System Installation Checklist Lighting Instructions Operating Your Water HeaterBurn Hazard Do not touch vent Doing so can result in burns Checking the DraftEmergency Shut Down Water Temperature RegulationBurner Flames StackingOperational Conditions Maintenance of Your Water Heater Routine Preventive MaintenanceDraining and Flushing Natural Gas Burner Ultra Low Nox Replacement PartsRemoving the Burner Door Assembly Replacing the Pilot AssemblyReplacing the Thermocouple Cleaning the Pilot AssemblyExternal Inspection & Cleaning of the Flame-trap Cleaning the Combustion Chamber and Flame-trapReplacing the Burner Door Assembly Testing the Igniter SystemPiezoelectric Igniter System Removing and Replacing the Gas Control Valve/Thermostat Flame LockSafety System Operational ChecklistSlow HOT Water Pilot Light Troubleshooting Chart Repair Parts List Repair Parts IllustrationListed Parts Kits and Illustrations Page